• Title/Summary/Keyword: 내화실험

Search Result 386, Processing Time 0.022 seconds

Structural Capacity Evaluation of High Strength Concrete Short Columns with Various Design Parameters under High Temperatures (고온하에서 다양한 설계변수에 따른 고강도 콘크리트 단주의 구조 성능 평가)

  • Kim, Hee-Sun;Mun, Ji-Young;Park, Jee-Eun;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.637-645
    • /
    • 2011
  • It is well known that high strength concrete with compressive strength higher than 50 MPa shows severe material and structural damages under fire due to spalling. To understand degradation of structural capacity of fire damaged high strength concrete structures, not only thermo-mechanical behavior needs to be defined, but also structural behavior of high strength concrete member under high temperature needs to be investigated. In this study, structural tests are performed by applying axial loads on high strength concrete columns exposed at elevated temperatures for assigned amount of time. The tested columns are prepared to have different concrete strength and polypropylene fiber percentage. The test results show that structural capacity of the columns decreased with increased compressive strength of concrete under same heating condition. Especially, it is interesting to note that high strength concrete columns with polypropylene fiber for spalling proof did not improve structural capacity compared to the columns without polypropylene fiber. The findings from the test are able to improve fire proof design of high strength concrete structural members and predicting structural performance of fire damaged structural members.

Experimental Study on Long-Term Performance Evaluation of Geosynthetic Strip Reinforcement (띠형 섬유보강재의 장기성능 평가를 위한 실험적 연구)

  • Lee, Kwang-Wu;Kim, Ju-Hyeung;Cho, Sam-Deok;Han, Jung-Geun;Yoon, Won-Il;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.4
    • /
    • pp.75-84
    • /
    • 2010
  • In this study, the long-term performance tests, which have extensibility, creep deformation, installation resistance and durability characteristic, is conducted to apply geosynthetic strip in field. The strength reduction factors using the test results are evaluated in order to calculate long-term design tensile strength. First, the creep deformation was evaluated by both the stepped isothermal method(SIM) and the time-temperature superposition(TTS) method. The creep reduction factor is reasonable to apply 1.6. Second, the result of installation damage test had little damage of yarn, which affected strength of reinforcement. Therefore, it can be analyzed that the installation damage of geosynthetic strip has little effect of long-term design tensile strength. Finally, the durability reduction factor considering chemical, biological and outdoor exposure resistance is reasonable to apply 1.1, which is considered the stability and economic efficiency of reinforced earth wall using geosynthetic strip.

  • PDF

Sintering phenomena and grain growth of ultra-fine spinel$(MgAl_2O_4)$; (I) (초미분 spinel$(MgAl_2O_4)$ 의 입성장 및 소결 현상 (I))

  • 이형복;한영환
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.1
    • /
    • pp.43-49
    • /
    • 1999
  • In the paper, Significant sintering phenomena at refractory temperature ranges, from $1400^{\circ}C$ to $1700^{\circ}C$, of the pure spinel ($MgAl_{2}O_{4}$) and the experimental data from other researchers are analysed and compared in terms of density ($\rho$), grain growth exponent(n), and activation energy (Q). Similar to the density rewsults, the grain growth results above $1600^{\circ}C$ appear similar for the spinel, but for temperatures lower than about $1600^{\circ}C$ results are distinctly differently grouped. However, the grain growth exponents are different, six for the spinel (below $1600^{\circ}C$), and five at high temperatures(above $1600^{\circ}C$), with the activation energy of 474$\pm$38 kJ/mol below $1600^{\circ}C$, which is very close to the published values, 360~580 kJ/mol.

  • PDF

Reforming of Expanded Graphite for Improving Fire Resistance of Fireproof Sealant (방화용 실란트의 내화성 향상을 위한 첨가제로서 팽창흑연의 개질)

  • Hong, In Kwon;Lee, Won Jae;Lim, Hyun Seok;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.437-441
    • /
    • 2017
  • This study was carried out to investigate the volumetric expansion ratio and hardness of expanded graphite after coating with various resins which were used as an additive of fireproof sealant. The coating thickness of the resin, which represents the coating rate, was dependent of the drying speed of the resin and the viscosity of the resin. Therefore the coating thickness was shown as follows: polyvinyl acetate > acrylic resin > urethane resin > water soluble latex. Furthermore, the volumetric expansion ratio was as follows: urethane resin > water soluble latex > acrylic resin > polyinyl acetate and the hardness was as follows: polyvinyl acetate resin > acrylic resin > water soluble latex > urethane resin. This showed that the volume of expansion was reduced by expansion, which was not covered by coating, but significantly increased by increasing hardness and allowed it to be used as a refractory addition. According to the response surface methodology, the optimized addition amount and stirring speed of acrylic resin were 37.6 wt% and 441.4 rpm, respectively.

Investigation of the Relationship Between Wall Thermal Conductivity and Inner Room Temperature in Compartment Fires (구획화재에서 벽면의 열전도 계수와 내부 온도의 상관관계 분석)

  • You, Woo Jun;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.17-23
    • /
    • 2018
  • In this study, the relations of the wall thermal conductivity and surface temperature in a compartment fire are investigated using Buckingham Pi theorem. The dimensionless parameters of the previous study are analyzed in order to correlate the dimensionless groups of the heat release rate, the thermal conductivity, the volume of compartment and the convective heat transfer coefficient. In addition the reduced scale of compartment, which has 1/6 size of ISO 9705 Room Corner Tester, is manufactured and the oxygen concentration and the maximum temperature in the space are measured for the gasoline pool fire ($10cm{\times}10cm$, $15cm{\times}15cm$ and $20cm{\times}20cm$). Finally, the criterion of the wall temperature increase are suggested in accordance with the thermal conductivity and the convective heat transfer coefficient. In addition, the dimensionless empirical equation using Buckingham Pi theorem considering the heat release rate are presented suggested. The results of this study will be useful especially for the fire phenomenon investigation of the wall thermal conductivity coefficient and shape in the compartment space.

An Experimental Study on Thermal Damage under Tunnel Fire Scenario to Concrete PC Pannel Lining (터널 화재시나리오에 따른 콘크리트 PC패널라이닝의 열적손상에 관한 실험적 연구)

  • Kim, Heung-Youl;Park, Kyung-Hun;Kim, Hyung-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.477-480
    • /
    • 2008
  • In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5 minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. Referring to foreign tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 39mm under ISO fire condition, 50mm under MHC and 100mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS. When PC panel was designed to serve the support, a fire resistance to the minimum depth of 100mm of the concrete that might be damaged under the fire shall be maintained, and in case of a non-support structure, PC lining shall have at least 100mm thickness.

  • PDF

Estimation Method of Residual Performance for Hollow Slab at Elevated Temperature (고온에 노출된 중공슬래브의 잔존성능 추정방법)

  • Choi, Hyun-Ki;Chung, Joo-Hong;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.643-650
    • /
    • 2014
  • Generally, the reinforced concrete slab has great fire resistance performance because concrete has excellent thermal material properties under fire. But, in the case of hollow slab, it will be expected that hollow slabs have different temperature distribution and fire endurance performance compare to reinforced concrete slab. Because hollow slab has internal void space that occurs decreasing regenerative effect of concrete and formation of internal air layer. Evaluation method for fire resistance performance of hollow slabs was proposed using $wickstr{\ddot{o}}m^{\prime}s$ method. For the casual use of evaluation, simplified method was proposed which was limited to solid slab and donut type hollow slab which was developed by authors of this research paper. Also, verification on proposed method was performed by comparing results of fire experiment for hollow slab and evaluation results. Proposed method of the results of this study was possible to predict the residual strength and temperature distribution of slabs under fire.

A Study on Chemical Resistance of Cement Mortar Blended with Thermally Activated Diatomite containing Heavy Metals form EAF Dust (EAF Dust사의 중금속을 함침한 활성 규조토가 혼합된 시멘트 모르터의 내화학성에 관한 연구)

  • 류한길;임남웅;박종옥
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.143-151
    • /
    • 1997
  • Chemical resistance of the cement mortar containing the Thermally Activated Diaomite(TAD) and H.M.(Heavy Metals) has been studied. The H.M.. extracted from EAF(Electrica1 Arc Furnace) Dust. were saturated with diatomite. The diatomite was then thermally activated at $750{\circ}C$ for 30minutes and powdeled. The powder was mixed with a portland cement on a weight basis from 0%. 2.5%. 5.0%. 10%. 20%. The optimum mixture. after those mixtures were subjected to compressive strength(7 and 28days) and leaching bchaviour of H.M.. was tested for its experiment on Wet/Dry cycles and chemical resistance(e.q. imrncrsion in 5%(Conc.) of H2S04, CaC12 and hlgSO4. It was shown that the cement, mortar containing 10% of' P.D. gave a rise to the remarkable increase in compressive strength. The compressive strength was generally decrease beyond the addition of 10% of P.D. The maximum $496kgf/cm^2$ of 28days compressive strength was acheiveti when 10% of P.D. was added to the cement mortar.

Engineering Properties of Sewage Polymer Concrete Culvert (폴리머 콘크리트를 적용한 하수암거의 공학적 특성)

  • Kwon, Seung Jun;Min, Byung Yoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2012
  • Concrete sewage culvert shows degradation with time since it is always exposed to various harmful ions, and deterioration of concrete culvert propagates to structural safety problems. After reclamation, maintenance for concrete sewage culvert is very difficult so that high durable and structural performance are essential for the sewage concrete culvert. Recently polymer concrete has been used to improve mechanical properties and durability performance. In this paper, engineering properties are evaluated for sewage culvert made with polymer concrete, and leakage and adhesive strength between joints are evaluated with small-scale models. The polymer sewage culvert shows high compressive strength over 100MPa with low water permeability and chloride penetration. Furthermore, high resistances to chemical and biological attack are evaluated. Through tests for leakage and adhesive, unification of joints is verified with evaluation of no leakage and high adhesive strength. Precast polymer sewage culvert in this paper can be actively used for severe conditions like sewage lines.

Properties of Repair Cement Mortar with C12A7-based Alumina Cement and Nitrite for Low Temperature Curing (C12A7계 알루미나시멘트 및 아질산염을 사용한 저온환경 보수시공용 시멘트 모르타르의 특성)

  • Park, Jung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.124-131
    • /
    • 2017
  • The purpose of this study is to evaluate the basic performance of cement mortar for repair using alumina cement and nitrite can be cured in low temperature environment. For this purpose, the repair mortar used in the domestic construction site was selected and the experimental evaluation was carried out by adjusting the mixing amount by substituting alumina cement and nitrite for the blending ratio. The experimental test results confirmed that alumina cement and nitrite were replaced with the repair mortar, the initial strength was improved. Also, the chemical resistance was improved, the shrinkage behavior was decreased, and the resistance to freezing and thawing was increased. As a result, applying alumina cement and nitrite at a ratio of 2:1 at 7.5%, the surface condition was maintained for 5 months or longer and it was judged to be excellent in practical use for external structures.