• Title/Summary/Keyword: 내진 안전성 평가

Search Result 139, Processing Time 0.033 seconds

Seismic Safety Evaluation of Bridge Based on Design Spectrum (교량 구조물의 설계 스펙트럼 기반 내진 안전성 평가)

  • Son, Ho-Young;Jung, Woo-Young;Ju, Bu-Seog;Kim, Sung-Jin
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.144-145
    • /
    • 2015
  • 본 논문에서는 지진 발생 시 교량 구조물의 내진 안전성 평가를 진행 하였다. 내진 안전성 평가는 KBC2009을 기준으로 대상 구조물이 위치한 지역에 맞는 설계 스펙트럼을 구축하여 해석을 진행 하였으며, 교량 모델은 상용 구조 해석 프로그램인 ABAQUS를 이용하여 간단한 선형 탄성 3D Beam 유한요소 모델링을 하였다.

  • PDF

Evaluation of the Seismic Safely of Concrete Gravity Dams (콘크리트 중력식 댐의 내진 안전성 평가)

  • 소진호;정영수;김용곤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.33-41
    • /
    • 2002
  • Recently, the seismic safety evaluation of concrete gravity dams is raised due to the damage or the failure of dams occurred by the 1995 Kobe earthquake, the 1999 Taiwan earthquake, etc. Failre of dam may incur loss of life and properties around the dam as well as damage to dam structure itself. Recently, there has been growing much concerns about 'earthquake-resistance' or 'seismic safety'of existing concrete gravity dams designed before current seismic design provisions were implemented. This research develops three evaluation levels for seismic safety of concrete gravity dams on the basis of the evaluation method of seismic safety of concrete gravity dams in U.S.A., Japan, Canada, and etc. level 1 is a preliminary evaluation which is for purpose f screening. Level 2 is a pseudo-static evaluation on the basis of the seismic intensity method. Finally, level 3 is a detail evaluation by the dynamic analysis. Evaluation results on existing concrete gravity dam on operation showed good seismic performance under the designed artificial earthquake.

Study on Seismic Performance Evaluation and Verification of Seismic Safety for Power Cable Tunnels (개착식 전력구의 내진성능 평가 및 내진 안전성 검증)

  • Hwang, Kyeong-min;Chun, Nak-hyun;Chung, Gil-young;Park, Kyung-sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.439-445
    • /
    • 2020
  • In this paper, the seismic performance evaluation was performed on 100 existing open-cut power cable tunnels, including ones that did not consider seismic design, in order to verify that the government's demand level (seismic special grade, 0.22 g). The results of the seismic performance evaluation show that most of the tunnels have seismic performance of 0.3 to 1 g, satisfying the level of the seismic special grade and securing the seismic safety. Meanwhile, the earthquake response analysis and structural test were performed to verify the validity of the method and the results of the seismic performance evaluation of the tunnels by the response displacement method, and to verify their seismic safety. As a result, the relative displacement due to the response displacement method under the 0.22 g earthquake was conservative than the results of the earthquake response analysis, and the results of load-displacement curves and response modification coefficient calculation by real scale structural tests showed the safety of the tunnels.

Modal Identification and Nonlinearity Assessment of Electric Cabinet for Improvement of Basic Fragility Variables (취약도변수의 개선을 위한 전기 캐빈비넷의 동특성 및 비선형성 평가)

  • 조양희;조성국;박형기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.83-91
    • /
    • 2000
  • 합리적인 기기의 활률론적 지진위험도 평가를 위해서는 모델의 동특성에 대한 보다 현실적인 정보가 제공되어야 한다. 이 연구에서는 심한 비선형 동적 거동을 보일 것으로 예상되는 철제 전기 캐비넷의 동특성 시험결과 및 분석 절차를 제시하였다. 특히, 이 연구에서는 가진 강도의 크기에 따른 동특성의 비선형 집중분석하고, 그 비선형성의 원인을 고찰하였다. 시험 결과 및 이 논문에 제시된 분석 절차를 이용하여 시험체의 동특성이 효과적으로 도출될 수 있으며, 대상 시험체는 가진 강도에 따라 심한 비선형 거동을 함을 입증하였다. 비선형성의 원인은 일반적인 재료 비선형이라기 보다는 각 부품들의 마찰력과 기하학적인 비선형성에 기인함을 발견하였다. 또한, 캐비넷 형식의 기긱에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다. 또한, 캐비넷 형식의 기기에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다.

  • PDF

Seismic Performance of Landing Pier with Batter Pile (경사말뚝이 있는 잔교식 안벽의 내진 성능 평가)

  • 권오순;장인성;박우선
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.92-99
    • /
    • 2002
  • 1995년 일본 고베지진 이후 우리나라에서도 지진에 대한 연구가 활발히 이루어지고 있으며, 현재 국내 여러 기간시설에 대한 내진안전성 평가와 내진설계가 실시되고 있다. 국내 기존 항만시설에 대해서도 내진 안정성 평가가 수행되고 있으며 현재계획ㆍ시공되고 있는 항만에서도 내진설계가 반영되고 있다. 중요한 항만시설물 중 하나인 잔교식 안벽은 연직말뚝과 경사말쪽을 조합하여 사용하고 있으나, 최근 내진설계에서 경사말뚝이 지진과 같은 동적 하중에 취약하다는 이유로 사용에 제한을 받고 있다. (중략)

  • PDF

Evaluation of Seismic Safety in School Buildings Applying Artificial Seismic Waves in Earthquake Magnitude of Korea (한국형 중진지역의 인공지진파 생성을 통한 학교건물 내진안전성 평가)

  • Kim, Seung-Hyun;Park, Young-Binuk;Kang, Jun-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • This report describes the development and stability evaluation of a seismic retrofit method to evaluate the seismic performance of existing school buildings by analyzing the earthquake waveforms that occurred in Korea. Currently, Facilities for seismic retrofit designed for excessive reinforcement are being applied. To compensate for this, optimised the retrofit mothod suitable for domestic situation considering the characteristics of the seismic region, generated a Korean-style artificial seismic wave that meets the seismic design criteria, which is less frequent than other countries.

Analysis on the Seismic Performance of Ceiling System in School Buildings (국내 학교시설 천장재의 내진성능 분석)

  • Park, Sung-Chul;Cho, Jin-Il;Jung, Tae-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2016
  • The purpose of this study is to develop the evaluation model of school facilities in terms of seismic performance during safety education in the school field. This study is composed of four stages with a view to developing user oriented evaluation models that can be utilized during earthquake safety education on ceiling system. and First stage analyze the evaluation guidelines to find evaluation methods and items. Based on the items, site survey was conducted to derive the characteristics of seismic performance of domestic school buildings in terms of ceiling system. Third stage analyzes the seismic performance of ceiling system. Final stage is to derive recommendations based on the results.

The Study of Reinforcement through the Nonlinear Static Analysis and Inelastic Seismic Performance Evaluation in School Building (학교건물에 있어서 비탄성해석 및 비선형 정적해석을 통한 내진성능 평가에 따른 보강 연구)

  • Lee, Ho;Kwon, Young-Wook;Kim, Hong-Do
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.55-63
    • /
    • 2012
  • This study is about earthquake-proof reinforcement through structural function evaluation of an school building. The purpose of this study is to comparatively analyze structure reinforcement measures in consideration of safety and usability through structural function evaluation of school buididng, to offer rational measures for earthquake-proof function and to provide help in maintaining safe structures against earthquake. For this purpose, was selected for this study as an existing school building, earthquake-proof function evaluation was conducted, and measures to reinforce earthquake-proof function was offered. As for the research method, the first and the second earthquake-proof function evaluations were conducted which is an existing reinforced concrete school building. Through the abovementioned methods, earthquake-proof function evaluation were conducted, the results were analyzed and the measure to reinforce earthquake-proof function were offered(Steel damper, Carbon plate stiffeners). The offered measure to reinforce earthquake-proof function was applied to the subject structure, and comprehensive results were derived from earthquake-proof function evaluation regarding before and after earthquake-proof function reinforcement.

Seismic Performance of Stainless Power Joints Piping System using Finite Element Analysis (압착식 조인트가 적용된 파이프라인 유한요소 해석)

  • Ju, Bu-Seog;Jeon, Bub-Gyu;Nam, Jun-Seok;Ryu, Yong-Hee;Son, Ho-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.145-146
    • /
    • 2017
  • 최근 세계적으로 많은 지진이 발생하고 있으며 기상이변으로 인한 자연재해로 인해 주요 시설물들의 안전성에 관한 관심이 증가하고 있는 추세이다. 특히 비구조 요소의 경우 구조 요소보다 건설 초기 투자비용이 높아 지진이 발생하였을 때 많은 피해가 발생할 가능성이 있으며 비구조 요소의 파괴는 심각한 2차피해로 발전 될 수 있으므로 내진안전성 평가는 반드시 이루어져야 한다고 볼 수 있다. 따라서 본 연구에서는 압착식 조인트의 접촉을 고려한 수계소화설비 파이프라인의 내진성능 평가를 위한 비선형 유한요소 모델을 구축하였다.

  • PDF

A Study on Seismic Performance Evaluation of Road Tunnel according to Seismic Analysis Conditions (내진해석 조건에 따른 도로터널 내진성능평가에 관한 연구)

  • Choi, Byoung-Il;Kim, Chan-Hee;Noh, Eun-Cheol;Ha, Myung-Ho;Park, Si-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.127-134
    • /
    • 2021
  • When constructing a tunnel on a stable ground, stress is changed in the ground during excavation stage and installation of ground support materials. In the standards for safety evaluation of structures in use, it is suggested to perform numerical analysis reflecting the excavation stage. But method of seismic performance evaluation was not presented. Therefore, in this study, numerical analysis was performed with different analysis methods, and the results were compared and analyzed. As a result of the numerical analysis, seismic wave applied in the horizontal direction were no difference depending on the analysis methods. However, there was a big difference in the result according to the evaluation methods of tunnel member forces. When reviewing with the strength design method, the structure performance could be not satisfied depending on the existence or nonexistence of reinforcing bars. Based on these research results, it is suggested that the interpretation method should be clearly presented and reflected in the relevant standards.