• Title/Summary/Keyword: 내진 안전성

Search Result 237, Processing Time 0.031 seconds

Seismic Safety Evaluation of Bridge Based on Design Spectrum (교량 구조물의 설계 스펙트럼 기반 내진 안전성 평가)

  • Son, Ho-Young;Jung, Woo-Young;Ju, Bu-Seog;Kim, Sung-Jin
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.144-145
    • /
    • 2015
  • 본 논문에서는 지진 발생 시 교량 구조물의 내진 안전성 평가를 진행 하였다. 내진 안전성 평가는 KBC2009을 기준으로 대상 구조물이 위치한 지역에 맞는 설계 스펙트럼을 구축하여 해석을 진행 하였으며, 교량 모델은 상용 구조 해석 프로그램인 ABAQUS를 이용하여 간단한 선형 탄성 3D Beam 유한요소 모델링을 하였다.

  • PDF

Study on Seismic Performance Evaluation and Verification of Seismic Safety for Power Cable Tunnels (개착식 전력구의 내진성능 평가 및 내진 안전성 검증)

  • Hwang, Kyeong-min;Chun, Nak-hyun;Chung, Gil-young;Park, Kyung-sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.439-445
    • /
    • 2020
  • In this paper, the seismic performance evaluation was performed on 100 existing open-cut power cable tunnels, including ones that did not consider seismic design, in order to verify that the government's demand level (seismic special grade, 0.22 g). The results of the seismic performance evaluation show that most of the tunnels have seismic performance of 0.3 to 1 g, satisfying the level of the seismic special grade and securing the seismic safety. Meanwhile, the earthquake response analysis and structural test were performed to verify the validity of the method and the results of the seismic performance evaluation of the tunnels by the response displacement method, and to verify their seismic safety. As a result, the relative displacement due to the response displacement method under the 0.22 g earthquake was conservative than the results of the earthquake response analysis, and the results of load-displacement curves and response modification coefficient calculation by real scale structural tests showed the safety of the tunnels.

Evaluation of the Seismic Safely of Concrete Gravity Dams (콘크리트 중력식 댐의 내진 안전성 평가)

  • 소진호;정영수;김용곤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.33-41
    • /
    • 2002
  • Recently, the seismic safety evaluation of concrete gravity dams is raised due to the damage or the failure of dams occurred by the 1995 Kobe earthquake, the 1999 Taiwan earthquake, etc. Failre of dam may incur loss of life and properties around the dam as well as damage to dam structure itself. Recently, there has been growing much concerns about 'earthquake-resistance' or 'seismic safety'of existing concrete gravity dams designed before current seismic design provisions were implemented. This research develops three evaluation levels for seismic safety of concrete gravity dams on the basis of the evaluation method of seismic safety of concrete gravity dams in U.S.A., Japan, Canada, and etc. level 1 is a preliminary evaluation which is for purpose f screening. Level 2 is a pseudo-static evaluation on the basis of the seismic intensity method. Finally, level 3 is a detail evaluation by the dynamic analysis. Evaluation results on existing concrete gravity dam on operation showed good seismic performance under the designed artificial earthquake.

L.R.B.를 이용한 면진설계의 내지진 안전성 연구

  • 구봉근;김태봉;우상익;이철희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.309-314
    • /
    • 1998
  • 외국의 경우, 지진활동이 활발하지 않은 지역에서 강진이 발생하고, 최근 국내의 빈번해진 지진 발생 등의 이유로 내진설계 기준의 정립 및 강화가 활발히 이루어지고 있다. 그러나 교량의 내진설계는 다음과 같은 몇 가지 한계점을 가지고 있다. l) 첫째 내진구조는 짧은 고유주기로 인하여 유발되는 지진력 자체가 매우 크다. 둘째, 설계지진을 능가하는 지진 발생시 구조물이 붕괴될 가능성이 크다. 즉 내진여유도가 작다. 셋째, 내진설계는 설계지진력 이상의 지진의 발생을 완전히 배제하지 않는데, 그러한 지진발생시 지지력이 모두 고정단이 위치한 교각에 집중되어 그 교각의 받침이 파괴되어 설계개념을 상실할 가능성이 높다. (중략)

  • PDF

A Study on Seismic Design Method Considering Physical Properties of Piping Material (배관 재료의 물성을 고려한 내진설계 방법에 관한 연구)

  • Bang, Dae-Suk;Lee, Jae-Ou
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.38-47
    • /
    • 2018
  • In this study, we compare the engineering seismic design method considering the physical properties of piping materials and the specification-oriented design method according to the seismic design standards of fire fighting equipment. In the case of the seismic design method considering the physical properties of piping materials, the safety of the piping will be analyzed through the combined value of the torsional stress and the bending stress generated in the piping. However, in the case of the design-centered design method, instead of the safety of the piping material, it calculates the moving force of the pipe and interprets whether or not the shaking prevention strut can bear. Fire extinguishing equipment piping is possible through safety analysis of stress and displacement of piping material because piping safety can not be secured via unstable force generated in a certain section with one connected structure is there. Therefore, it is necessary to apply analytical method considering seismic performance of building structure and material properties of piping for seismic design of safe fire extinguishing system piping.

Evaluation of Seismic Safety in School Buildings Applying Artificial Seismic Waves in Earthquake Magnitude of Korea (한국형 중진지역의 인공지진파 생성을 통한 학교건물 내진안전성 평가)

  • Kim, Seung-Hyun;Park, Young-Binuk;Kang, Jun-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.10-18
    • /
    • 2022
  • This report describes the development and stability evaluation of a seismic retrofit method to evaluate the seismic performance of existing school buildings by analyzing the earthquake waveforms that occurred in Korea. Currently, Facilities for seismic retrofit designed for excessive reinforcement are being applied. To compensate for this, optimised the retrofit mothod suitable for domestic situation considering the characteristics of the seismic region, generated a Korean-style artificial seismic wave that meets the seismic design criteria, which is less frequent than other countries.

Modal Identification and Nonlinearity Assessment of Electric Cabinet for Improvement of Basic Fragility Variables (취약도변수의 개선을 위한 전기 캐빈비넷의 동특성 및 비선형성 평가)

  • 조양희;조성국;박형기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.83-91
    • /
    • 2000
  • 합리적인 기기의 활률론적 지진위험도 평가를 위해서는 모델의 동특성에 대한 보다 현실적인 정보가 제공되어야 한다. 이 연구에서는 심한 비선형 동적 거동을 보일 것으로 예상되는 철제 전기 캐비넷의 동특성 시험결과 및 분석 절차를 제시하였다. 특히, 이 연구에서는 가진 강도의 크기에 따른 동특성의 비선형 집중분석하고, 그 비선형성의 원인을 고찰하였다. 시험 결과 및 이 논문에 제시된 분석 절차를 이용하여 시험체의 동특성이 효과적으로 도출될 수 있으며, 대상 시험체는 가진 강도에 따라 심한 비선형 거동을 함을 입증하였다. 비선형성의 원인은 일반적인 재료 비선형이라기 보다는 각 부품들의 마찰력과 기하학적인 비선형성에 기인함을 발견하였다. 또한, 캐비넷 형식의 기긱에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다. 또한, 캐비넷 형식의 기기에 대한 합리적인 내진안전성 평가를 위해서는 각 방향별로 서로 다른 감쇠값을 적용할 것을 추천하였다.

  • PDF

Seismic Performance of Landing Pier with Batter Pile (경사말뚝이 있는 잔교식 안벽의 내진 성능 평가)

  • 권오순;장인성;박우선
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.92-99
    • /
    • 2002
  • 1995년 일본 고베지진 이후 우리나라에서도 지진에 대한 연구가 활발히 이루어지고 있으며, 현재 국내 여러 기간시설에 대한 내진안전성 평가와 내진설계가 실시되고 있다. 국내 기존 항만시설에 대해서도 내진 안정성 평가가 수행되고 있으며 현재계획ㆍ시공되고 있는 항만에서도 내진설계가 반영되고 있다. 중요한 항만시설물 중 하나인 잔교식 안벽은 연직말뚝과 경사말쪽을 조합하여 사용하고 있으나, 최근 내진설계에서 경사말뚝이 지진과 같은 동적 하중에 취약하다는 이유로 사용에 제한을 받고 있다. (중략)

  • PDF

Development of Earthquake Resistant Analysis Models for Typical Roadway Bridges (일반도로교의 내진해석모델 개발)

  • 국승규;김판배
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.1-6
    • /
    • 2002
  • The structural safety required in general design is to be proved with safety factors provided for structural members in elastic range. But, for the safety requirement in the earthquake resistant design, a specific ductile failure mechanism in plastic range should be verified according to the structural configuration. Therefore such verifications should be done in the preliminary design stage by comparing various design alternatives. In the main design stage only a confirmation of the ductile failure mechanism is required. In this study typical roadway bridges are selected and analysis models are presented for the preliminary and main design. For the two models, vibration periods and mode shapes are compared and the multi-mode spectrum method is applied to determine failure mechanisms. The failure mechanisms obtained with the two models are compared to check the properness of the model used for the preliminary design, which may well be used as an earthquake resistant analysis model in practice.

배관계통의 내진해석에 따른 응답조합과 누락질량효과

  • 이범수
    • Journal of the KSME
    • /
    • v.25 no.4
    • /
    • pp.304-311
    • /
    • 1985
  • 원자력발전소는 사고시 주변의 인구 및 환경에 미치는 영향의 심각성을 고려하여 가능한 모든 안전조치를 취하여 설계. 건설되도록 하고 있다. 특히 원자로냉각재 계통의 배관이 그러하며 고도의 안전성 및 신뢰성을 확보하기 위하여 지진에 대해서도 구조적인 건전성이 입증되어야 한다. 일반적으로 지진하중에 대한 배관계통의 내진해석에서는 층응답스펙트럼에 의한 모우드 해석 방법이 이용되고 있다. 이 때 내진해석으로 얻어진 응답의 조합에는 신중한 고려가 필요 하다. 즉 배관계통의 특성, 입력지진의 특성, 계산에 고려하는 모우드의 수등을 감안하여 적절한 응답조합이 이루어져야 한다. 본 해설에서는 여러 가지의 응답조합방법과 해석시 고려되는 모 우드의 수를 제한함으로써 발생하는 오차를 보정하기 위한 누락질량효과(missing mass effect)에 대하여 설명하고자 한다. 또 두 가지의 해석모델에 대하여 실제 내진 해석을 수행하여 그 결 과를 비교검토하기로 한다.

  • PDF