• Title/Summary/Keyword: 내진 검증

Search Result 315, Processing Time 0.023 seconds

Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6 (울진 원자력발전소 5,6 호기용 공기정화기에 대한 내진검증)

  • Kim, Jin-Young;Rhee, Hui-Nam;Lee, Joon-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1376-1383
    • /
    • 2002
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed are condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.

Seismic Qualification of the Air Conditioning Equipment for Nuclear Power Plant (원자력 발전소용 공조기에 대한 내진검증)

  • 이준근;김진영;정필중;정정훈
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.535-543
    • /
    • 1999
  • The seismic qualification of the structures has been great concern in our engineering society with an effort to reduce the severe damages from an earthquake. However, on the contrary to the importance of the seismic qualification, the whole procedures are used to rely on the advanced countries who require various expenses for the qualification, which leads to the heavy loss of the foreign currency. In this study, the nuclear air conditioning system produced by LG Cable are adopted for the seismic qualification based on the guideline of NUREG, IEEE and ASME code. In order to confirm the validity of the present study, the results from the Ellis & Watts are compared with the present results and, also, the seismic qualification procedures and results mentioned herein are approved by KOPEC, which is a naitonal surveillance institute for the construction of nuclear power plant. From these results, the author confirmed the validity of the present seismic qualification procedures and results, which might be usefully applied to the other kind of seismic qualification of equipments.

  • PDF

Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6 (울진 원자력발전소 5,6호기용 공기정화기에 대한 내진검증)

  • Lee, Joon-Keun;Kim, Jin-Young;Chung, Phil-Joong
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.404-409
    • /
    • 2001
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed is condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.

  • PDF

Seismic Qualification of the Main Control Board for Nuclear Power Plant (원자력발전소용 주 제어반의 내진 검증)

  • 변훈석;이준근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.856-863
    • /
    • 2002
  • Seismic qualification of the main control board(MCB) for the nuclear power plant Ulchin 5 and 6 has been performed with the guideline of ASME Section III and IEEE 344 code. As the size and weight of the MCB are too large and heavy to excite using the excitation table, finite element analysis is used in order to investigate the dynamic behaviors and structural integrity of the MCB. As the fundamental frequencies of the equipment are found to be less than 33 Hz, which is the upper frequency limit for the dynamic analysis, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the electrical stability of the major components of the MCB. modal analysis theory has been adopted to derive the required response spectra at the component locations. As the all combined stresses obtained from the above procedures are less than the allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors can confirm the safety of the nuclear equipment MCB under the given seismic loading conditions.

Evaluation of Seismic Performance for Bridge Using Capacity Spectrum Method (역량스펙트럼을 이용한 교량의 내진성능평가)

  • Park, Yeon-Soo;Choi, Sun-Min;Kin, Eung-Rok;Suh, Byoung-Chul
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.448-455
    • /
    • 2007
  • In 1992, the first design standard of quake proof bridge was established. However, most bridge structures which were constructed without considering earthquake in former times need performance of quakeproof property. Quakeproof analysis in current bridges, is based on analysis of load base which just has strength over the load of simple structures but is not checked through simple comparison of strength performance of structures so that we would like to check that ADRS method is reasonable or not using ADRS method(Accleration-Displacement Response Spectrum Method), a analysis method based on displacement of object of performance test. As the result of that, the capacity spectrum method can avoid complex dynamic analysis in analysis based on loads and it efficiently applies to design verification with normal checking for quakeproof performance and aimed performance of new structures. However we can not consider effects of high modes and it has problem that does not consider falling of performance in structures by repeated load.

  • PDF

Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method (Part 1:Analytical Study) (TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 1:해석적 연구))

  • Jung, Myung-Cheol;Song, Jeong-Weon;Song, Jin-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.141-147
    • /
    • 2018
  • In this study, a cyclic loading test was carried out for a reinforced concrete frame installed a TS(tension-spring) damper for the purpose of verifying the seismic strengthening effect of the TS seismic reinforcing method. The test specimens are four specimens of non - reinforced frame and three reinforced frame specimens. Experimental parameters are Shape of damper and construction method of damper. As a result, the construction method of inserting type inside window was twice as much in terms of strength and stiffness, and the method of externally attached type showed a performance improvement of about 2 times in terms of energy dissipation. From these results, it can be confirmed that the TS seismic reinforcing method is a superior method for field application and seismic strengthening.

Verification of 2-Parameters Site Classification System and Site Coefficients (I) - Comparisons with Well-known Seismic Code and Site Response Characteristics (2-매개변수 지반분류 방법 및 지반 증폭계수의 검증 (I) - 국외 내진설계기준 및 부지응답특성과의 비교)

  • Lee, Sei-Hyun;Sun, Chang-Guk;Ha, Jeong-Gon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.25-34
    • /
    • 2012
  • In order to verify that the recently proposed two-parameters site classification system and the corresponding site coefficients are suitable for the local geological conditions in Korea, a comparison was conducted with current Korean seismic code, Eurocode-8, NYC DOT seismic code. The design spectrum of the current Korean seismic code is significantly amplified in the long-period range, whereas the other response spectra, including the proposed two-parameters approach, are significantly amplified in the short-period range, which is a typical geological condition in Korea. In addition, based on the results of site response analyses in the specific $10km{\times}10km$ area of Gyeongju, spatial distributions of site coefficients from site-specific seismic response analyses were compared with the proposed site coefficients, as well as those specified in the current Korean seismic code. The site coefficients ($F_a$ and $F_v$) from the current Korean seismic codes show significantly high spatial error distributions compared with those specified by the two-parameters site classification system. Therefore, the proposed system is suitable for regions of shallow bedrock including the Korean peninsula.

A Study on Seismic Performance of High-Strength Steel(POSTEN60, POSTEN80) Pipe-Section Piers using 3-Dimensional Elastic-Plastic Finite Deformation Analysis (3차원 탄소성 유한변위해석을 이용한 고강도(POSTEN60, POSTEN80) 원형강교각의 내진성능에 관한 연구)

  • Chang, Kyong-Ho;Jang, Gab-Chul;Kang, Jae-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.6 s.40
    • /
    • pp.45-54
    • /
    • 2004
  • Recently, as steel structures become higher and more long-spanned, application of high-strength steels is increasing gradually. For seismic design of steel structures using high-strength steels(POSTEN60, POSTEN80), analytical method, can describe the large deformation and inelastic cyclic behavior generated by non-proportional cyclic loading, are required. In this paper, cyclic plasticity model was proposed by results of monotonic loading tests ant cyclic loading tests. Three-dimensional finite element analysis is developed by using proposed model and finite deformation theory and verified as compare with experiment result. Using 3-dimensional elastic-plastic finite deformation analysis, seismic analysis of high-strength steel pipe-section piers are carried out. Also, seismic performance of high-strength steel pipe-section piers in parameter of diameter-thickness ratio was clarified.

Seismic Performance of Reinforced Concrete Frame with Masonry Waist-high Wall using Aramid Fiber (아라미드 섬유를 이용한 철근콘크리트 프레임 면내 조적 허리벽의 내진보강성능)

  • Kim, Hye-Jin;Cho, Seung-Ho;Rho, Kwang-Geun;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.99-100
    • /
    • 2009
  • In this paper, wish to achieve an experimental study to investigate enhanced performance of the masonry walls strengthened in shear and ductility using Aramid fiber strip.

  • PDF