• Title/Summary/Keyword: 내진진단규준

Search Result 3, Processing Time 0.018 seconds

Estimation of Seismic Performance and Earthquake Damage Ratio of Existing Reinforced Concrete Buildings in Japan (일본의 기존 철근콘트리트건물의 내진성능 및 지진피해율의 평가)

  • 이강석;이리형
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2000
  • The main objective of this paper is to apply as the basic data for development of a methodology to discuss the future earthquake preparedness measures in Korea by investigating the concept and applicabilities of the Japanese Standard for Evaluation of Seismic Performance of Existing RC Buildings developed in Japan among the methodologies of all the countries of the world. This paper describes the seismic performance, Is-index, of existing RC buildings in Tokyo, Japan evaluated by the Japanese Standard, also the relationships between Is-index distribution of existing RC buildings in Tokyo and that of Shizuoka and Chiba Prefecture reported already in reference[4][5][6] are investigated. And from the comparison with Is-index to buildings damaged by earthquakes experienced in Japan, the damage ratio due to severe earthquake of 3 districts mentioned above is estimated based on the probabilistic point of view. The results of this study can be utilized to identify urgently required earthquake preparedness measures with highest priority in existing RC buildings, and the methodology to evaluate the seismic performance of existing RC buildings in Japan, statistics analysis method and the methodology to estimate earthquake damage ratio based on the probabilistic point of view shown in this study can be recommended to develop a methodology to discuss the future earthquake preparedness measures in Korea.

  • PDF

Seismic Resistance Response of Railway Station Building Retrofitted by Metallic Dampers (강재댐퍼를 적용한 역사 건물의 내진 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • The purpose of this research is a seismic capacity evaluation and strengthening of existing railway station buildings, which were constructed before the seismic design code activated. The seismic capacity of 2nd story RC station building is evaluated by using nonlinear time-history analysis. Analysis results are checked by story drift ratio and story shear, which are described in design code. As a result, the story shears are exceeding the base shear of the design code, the appropriate seismic strengthening methods are needed. To improve the seismic capacity, metallic dampers are used. Evaluation parameters are metallic damper shape and damper installation methods. Dampers are installed in four places in X and Y directions of station buildings. By reviewing of time-history analysis results, the metallic damper, which is installed inverted K-brace type, shows a better seismic performance than other damper shape and installation methods.

Seismic Performance Enhancement of Residential Flat Plate Structure by Using Base Isolation Devices. (면진장치를 사용한 주거용 무량판구조의 내진성능 향상)

  • Lee, Hyun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • For the seismic performance enhancement of residential flat plate structure and for the selection of earthquake records, the possibility of base isolation is evaluated and the time history results are reviewed. By evaluating a base isolated stiffness, a target period, and an envelope curve analysis, seismic performance of structure, which has strong rotational mode, is evaluated. For the propriety evaluation of earthquake records usage and scaling method, time history analysis is done with variables such as DBE(design base earthquake) level, MCE(maximum considerable earthquake) level, and 1.4DBE level. From the analysis results, following conclusions can be made; the earthquake records, which are used in base isolation analysis, should be selected by similar soil type which the structure is considered, and should be intensity scaled in a range of mean ${\pm}$ standard deviation of code based design response spectrum.