• Title/Summary/Keyword: 내진성능 평가

Search Result 896, Processing Time 0.022 seconds

Displacement-based Seismic Assessment and Rehabilitation of Asymmetric Wall Structures (비대칭 벽식 구조지 변위기초 내진성능평가 및 보강)

  • Hong, Sung-Gul;Ha, Tae-Hyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.23-32
    • /
    • 2005
  • Torsional behavior of eccentric structure under seismic leading may cause the stress and/or deformation concentration, which arouse the failure of the structure in an unexpected manner. This study suggests D-R relationship which shows the overall displacement and rotation of the system based on the ultimate displacement capacity of the each lateral load resistant member. Using the suggested D-R relationship and displacement spectrum, the seismic assessment is conducted and verified in comparison with the time history analysis result. Multi-level seismic assessment Is considered which takes multiple seismic hazard levels and respective performance levels into account. Finally, based on the seismic assessment result, seismic rehabilitation process is presented. In this research, two rehabilitation methods are considered. One is done by means of stiffening/strengthening the seismic resistant members, and the other is based on the member ductility. Especially, in the first method, to optimize the rehabilitation result, the rehabilitation problem is modeled as an optimization problem, and solved using BFGS quasi-Newton optimization method.

Seismic Performance Evaluation of Building Structures Based on the Adaptive Lateral Load Distribution (적응적 횡하중 분배방법을 이용한 건축구조물의 내진성능평가)

  • 이동근;최원호;정명채
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.39-58
    • /
    • 2004
  • It is very important that predict the inelastic seismic behavior exactly for seismic performance evaluation of a building in the performance based seismic design. Evaluation method of seismic performance based on the pushover analysis reflected in PBSE was developed by some researchers. For the evaluation of inelastic global and local seismic responses by pushover analysis exactly. lateral load distribution should be adjusted and reflected the dynamic characteristics of structural system and various seismic ground motions. And performance point should be determined based on the evaluation of reasonable deformation capacity of a building more exactly. An effective method based on the improved the adaptive lateral load distribution and the equivalent responses of a multistory building is proposed in this study to efficiently estimate the accurate inelastic seismic responses. The proposed method can be used to evaluate the seismic performance for the global inelastic behavior of a building and to accurately estimate its local inelastic seismic responses. In order to demonstrate the accuracy and validity of this method, inelastic seismic responses estimated by the proposed method are compared with those obtained from other analytical methods.

Cyclic Testing of Bracket and WUF-B Type Weak-Axis Steel Moment Connections (브라켓 및 WUF-B 형식 철골모멘트골조 약축접합부 내진성능평가)

  • Lee, Kang Min;Jeong, Hee Taek;Yoon, Seok Ryong;Lee, Eun Mo;Oh, Kyung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2008
  • There has been much focus on the strong axis steel moment connections after the Northridge earthquake in 1994. However, research studieson the seismic behavior of weak axis moment connections could be hardly found despite the fact that these connection details have been frequently used as seismic details of MRF in Korea. Therefore, the objective of this research is to provide better knowledge on the seismic behavior of weak-axis steel moment connections, which can be widely applicable to many structures with similar characteristics. For this purpose, an experimental program was designed and performed with twotypes of weak-axis steel moment connections, namely the bracket type and WUF-B type, based on the survey of existing field data and literatures. Using the experimental results obtained from the quasi-static cyclic testing of these specimens, structural performances of the joints such as hysteretic curves, maximum strength capacities and the strain of reinforced bars were investigated. From the test results, the bracket-type connection was shown to have more than a 5% story drift capacity, compared with the WUF-B type connection's 4%. These specimens were also shown to have higher strength capacities than the nominal design strength. The bracket-type connection showed a slow strength degradation after maximum strength was researched. However,the WUF-B type connection showed a rapid strength degradation that caused brittle behavior.

Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure (확률론적 지진위험도 분석을 위한 원전 격납건물의 비탄성에너지 흡수계수 평가)

  • 최인길;서정문
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.47-56
    • /
    • 2001
  • In order to assure the safety of NPP structures, margin of safety or conservatism is incorporated in each design step. Seismic risk evaluation of NPP structures is performed based on the realistic capacity and response of structure eliminated the safety margin and conservatism. In this study, the comparative study on the various evaluation methods of the inelastic energy absorption capacity was performed. The inelastic energy absorption capacity due to the nonlinear behavior of structures has significant effect on the results of seismic probabilistic risk assessment. And the comparison study of the HCLPF(high confidence of low probability of failure) values according to the inelastic energy absorption factors was performed. As a conclusion, the inelastic energy absorption factor of NPP containment structure is estimated about 1.5~1.75. It is essential to estimate the nonlinear behavior of structure and its ductility factor correctly for the seismic risk assessment.

  • PDF

Fragility Analysis for Evaluation and Comparison of Seismic Performance of Building Structures (취약도 해석을 통한 빌딩구조물의 내진성능 비교 및 평가)

  • Park, Joo-Nam;Choi, Eun-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.11-21
    • /
    • 2007
  • Potential damage and losses associated with structural systems caused by earthquake can be reduced by application of seismic design to the structures. Because the building cost required for seismic design is generally higher than the cost for non-seismic design, the application of seismic design must be justified considering both seismic performance and cost. This paper presents a risk-based fiamework for evaluation and comparison of seismic performance of structures such that necessary data can be supplied for decision making on seismic design. Seismic fragility curve is utilized for seismic risk assessment of structures, and the process for decision analysis on adaptation of seismic design is presented based on the equivalent cost model.

Seismic Performance Evaluation of Full-size Non-seismic Circular RC Bridge Piers with Longitudinal Steel Lap splice (주철근 겹침이음된 실물 비내진 원형 교각의 내진성능평가)

  • Chung Young-Soo;Lee Dae-Hyung;Ko Seong-Hyun;Lee Jae-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.697-707
    • /
    • 2004
  • Most bridge piers were practically designed and constructed with lap spliced longitudinal reinforcing steels before the 1992 seismic design provisions of Korea Bridge Design Specification were implemented. It has been known that lap splice of longitudinal reinforcement in the plastic hinge region is not desirable for seismic performance of RC bridge piers. The objective of this research is to evaluate the seismic performance of existing circular reinforced concrete bridge piers by the Quasi-static test and to propose the need of seismic retrofit of existing bridge piers through the damage level. Test specimens were nonseismically designed with the aspect ratio 4.0 which could induce the flexural failure mode. It was confirmed from this experiment that significant reduction of seismic performance was observed for test specimens with lap spliced longitudinal reinforcing steels. Pertinent seismic retrofit was determined to be needed for existing RC bridge piers with the lap-spliced of $50\%$ longitudinal reinforcing steels.

Seismic Vulnerabilities of a Multi-Span Continuous Bridge Considering the Nonlinearity of the Soil (지반 비선형성을 고려한 다경간 연속교의 지진취약도)

  • Sun, Chang-Ho;Lee, Jong-Seok;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.59-68
    • /
    • 2010
  • Seismic performances of existing structures should be assessed with more accuracy for cost-effective retrofits. Existing bridges are assessed by the current guidelines in which a simple method has been adapted considering the technical level of engineers of the historical time of construction. Recently many probabilistic approaches have been performed to reflect the uncertainties of seismic input motions. Structures are modeled frequently with the neglection of soil foundations or modeled occasionally with elastic soil spring elements to consider the effect of the soil on the structural response. However, soil also shows nonlinearity under seismic events, so this characteristic should be reflected in order to obtain a more accurate assessment. In this study, a 6-span continuous bridge has been analyzed under various seismic events, in which the soil was represented by equivalent linear spring elements having different properties according to the intensities of the input motions experienced. The seismic vulnerabilities with respect to the failure of piers and the dropping of the super-structure were evaluated on the basis of the analysis results.

Seismic Performance Evaluation of Circular RC Bridge Piers with Shear-Flexure Behavior (휨-전단 복합 거동을 보이는 RC 원형교각의 내진성능 평가)

  • 김병석;김영진;곽임종;조창백;조정래
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.29-36
    • /
    • 2001
  • Same as-built drawings in national roadway bridges in Korea were examined. As a result, many bridge piers were found whose aspect ratios are in the vicinity of 2.5. These columns are expected to do shear-flexure behaviour, but the previous research works considered flexure behaviour columns only. In the study, therefore, a shear-flexure behaviour column was selected as the model pier, and quasi static test on the full and 1/2 scale models was carried out. From the test results, the scale effect on the seismic performance evaluation was analyzed, and the seismic performance of the model bridge pier without seismic details was evaluated by the capacity spectrum method.

  • PDF

Decision Making of Seismic Performance Management for the Aged Road Facilities Based on Road-Network and Fragility Curve (취약도곡선을 이용한 도로망기반 노후도로시설물 내진성능관리 의사결정)

  • Kim, Dong-Joo;Choi, Ji-Hae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.94-101
    • /
    • 2021
  • According to the Facility Management System (FMS) operated by the Korea Authority of Land & Infrastructure Safety, it is expected that the number of aging facilities that have been in use for more than 30 years will increase rapidly to 13.9% in 2019 and 34.5% in 2929, and end up with a social problem. In addition, with the revision of "Common Application of Seismic Design Criteria" by the Ministry of Public Administration and Security in 2017, it is mandatory to re-evaluate all existing road facilities and if necessary seismic reinforcement should be done to minimize the magnitude of earthquake damage and perform normal road functions. The seismic performance management-decision support technology currently used in seismic performance management practice in Korea only determines the earthquake-resistance reinforcement priority based on the qualitative index value for the seismic performance of individual facilities. However with this practice, normal traffic functions cannot be guaranteed. A new seismic performance management decision support technology that can provide various judgment data required for decision making is needed to overcome these shortcomings and better perform seismic performance management from a road network perspective.

Seismic Performance Assessment of RC Bridge Columns using Inelastic Finite Element Analysis (비탄성 유한요소해석을 이용한 철근콘크리트 교각의 내진성능평가)

  • Kim, Tae-Hoon;Chung, Young-Soo;Shin, Hyun-Mock
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.63-74
    • /
    • 2005
  • The purpose of this study is to assess the seismic performance of reinforced concrete bridge columns using inelastic finite element analysis. The accuracy and objectivity of the assessment process may be enhanced by the use of sophisticated nonlinear finite element analysis program. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. Damage index aims to provide a means of quantifying numerically the damage in reinforced concrete bridge columns sustained under earthquake loading. The proposed numerical method for the seismic performance assessment of reinforced concrete bridge columns is verified by comparison with reliable experimental results.