Journal of the Earthquake Engineering Society of Korea
/
v.5
no.2
/
pp.49-57
/
2001
본 연구의 목적은 유사동적실험에 의한 섬유보강 원형 RC교각의 내진성능평가를 위한 연구로서 수원시에 위치한 내진교량인 하길교를 대상모델로 하였으며, 도로교 표준시방서의 내진설계규정이 적용되지 않은 비내진교각시험체 2본 및 내진성능향상을 위한 섬유보강시험 4본, 즉 총 6본에 대하여 유사동적실험을 수행하였다. 보강공법으로는 유리 탄소섬유 보강공법을 사용하였으며, 실험변수로는 입력지진동, 섬유고방유무로 하였다. 그리고 내진성능평가 방법은 입력 및 소산에너지, 변위 연성도가 분석되었다. 본 실험의 결과 유리 섬유로 보강된 비내진시험체의 변위연성도 KHC인공지진파에 대하여 7.7~9.0정도의 값으로 충분한 내진성능을 확보하고 있는 것으로 평가되었다.
Journal of the Earthquake Engineering Society of Korea
/
v.8
no.2
/
pp.9-17
/
2004
The seismic performance evaluation and retrofit process are very important in old existing bridges. If the result is not appropriate. then a retrofit process are required. Among various retrofit methods, the seismic isolation is a very useful method. because it can be applied by replacing old bridge bearings. In this study, the effectiveness of seismic isolation is rationally verified. For this purpose, two seismic isolations used widely are selected and non-linear static and dynamic analyses are performed. The responses of existing bridges are compared with those of retrofited bridges by seismic isolation bridge for earthquake of target level. and seismic performances are evaluated.
내진 설계규정이 적용되기 이전에 시공되어 사용 중인 교량의 경우 지진 발생시 교각의 파괴 또는 구조적 피해는 교량 전체 시스템의 붕괴를 초래하므로 지진하중에 대하여 피해를 최소화해야 한다. 이를 위해 내진설계규정이 적용되기 이전의 교량 또는 지진취약지역으로 분류된 곳의 교량, 사회적 중요도가 높은 교량에 대해 교각의 내진성능보강을 실시하고 있다. 2007년 말 국토해양부가 관리하고 있는 11,940개 교량 중 지진 발생시 피해가 우려되는 1,342개(일반국도 682개, 고속국도 600개) 교량에 대해 2006년부터 내진보강이 착수되었고 2009년에는 확대 추진하여 일반국도 80개교, 고속국도 100개교에 대한 보강을 실시하였다. 이와 같이 확대 추진되고 있는 정책에 반해, 내진보강 기술 및 제품이 부족하고 새로운 내진보강재 개발이 불가피해지고 있는 것이 현실이다. 소성영역에서의 횡방향 철근은 지진 시 종방향 철근의 좌굴과 콘크리트의 압축강도저하를 방지하며, 전단보강철근으로도 중요한 역할을 하여 교각의 전단강도를 증가시킨다. 그러나 이러한 횡방향 철근은 초기 설계에 의한 시공이 종료된 후 기존의 성능을 증가시키기 위하여 철근량을 증가하거나 단면의 변화를 주기에는 매우 어려운 일이다. 따라서 내진성능을 위한 단면력 증가를 위하여 다양한 재료의 보강재와 형식이 사용되고 있다. 본 연구에서는 원형교각 모델의 구조해석을 이용해 내진성능평가를 선행한 후 실험체를 제작, Helical Bar를 보강하여 준정적 실험을 통해 내진보강성능을 평가하였다. 압축설계강도 $f_{ck}=240kgf/cm^2$를 기준으로 교량등급 2등교인 일반적인 도로교의 1/4축소모형을 설계, 기초부는 $1,200{\times}600{\times}600$ (mm)으로 철근과 콘크리트로 구성하였으며, 기둥부는 직경 400mm, 높이 1,250mm 크기의 철근콘크리트 원형 교각 실험체를 제작하였다. 제작된 실험체는 총 3개로, 분류는 무보강 일반 실험체, Helical Bar 직경에 따른 분류, 보강간격에 따른 분류로 나누어진다.
Journal of Korean Association for Spatial Structures
/
v.12
no.2
/
pp.55-63
/
2012
This study is about earthquake-proof reinforcement through structural function evaluation of an school building. The purpose of this study is to comparatively analyze structure reinforcement measures in consideration of safety and usability through structural function evaluation of school buididng, to offer rational measures for earthquake-proof function and to provide help in maintaining safe structures against earthquake. For this purpose, was selected for this study as an existing school building, earthquake-proof function evaluation was conducted, and measures to reinforce earthquake-proof function was offered. As for the research method, the first and the second earthquake-proof function evaluations were conducted which is an existing reinforced concrete school building. Through the abovementioned methods, earthquake-proof function evaluation were conducted, the results were analyzed and the measure to reinforce earthquake-proof function were offered(Steel damper, Carbon plate stiffeners). The offered measure to reinforce earthquake-proof function was applied to the subject structure, and comprehensive results were derived from earthquake-proof function evaluation regarding before and after earthquake-proof function reinforcement.
After the earthquake in South Korea (Gyeongju and Pohang), interest in securing the seismic performance of piloti buildings was increasing. In this paper, a study was conducted to propose a seismic retrofit method for piloti building of LH. The proposed seismic retrofit method considers the priority of seismic retrofit and the type of core. To verify the effectiveness of the proposed seismic retrofit method, computational analysis was performed according to the type of core. As a result, it was confirmed that the seismic performance was improved when the proposed seismic retrofit method was used.
The objective of this experimental research is to assess the seismic performance of circular RC bridge pier specimens retrofitted with fibers which were designed as a prototype of Hagal bridge in the city of Suwon, Korea. Pseudo dynamic test has been done for four(4) test specimens which were nonseismically or seismically designed by the related provisions of the Korea roadway bridge design specification, and four nonseisemic test specimens retrofitted with fibers in the plastic hinge region. Glass and carbon fiber sheets were used for the seismic capacity enhancement of circular test specimens. Important test parameters were confinement steel ratio, load pattern, and retrofitting. The seismic behavior has been analyzed through the displacement ductility, energy analysis, and capacity spectrum. Approximate 7.7 ∼8.7 displacement ductility was observed for nonseismic test specimens retrofitted with fibers subjected to Korea Highway Cooperation artificial earthquake motions. It is concluded that these retrofitted test specimens could have sufficient seismic capacity in the region of moderate seismic zone.
Park, Jin Hwa;Ahn, Tea Sang;Seo, Hyun Sik;Kim, Sang Dea
한국방재학회:학술대회논문집
/
2011.02a
/
pp.29-29
/
2011
국내에서 기존건축물의 내진성능평가 기법이 연구되기 시작한지 20여 년간 다양한 평가방법이 제안되었다. 그러나, 제안된 평가방법은 미국이나 일본의 평가 방법을 도입 및 수정하는 내용이 주가 되어 국내실정에 맞지 않는 부분도 많이 발견되었다. 따라서 국내에서 제안된 기존 건축물의 내진성능 평가기법, 지진피해예측에 근거한 보강건축물의 합리적인 선정방법 및 이들 건축물에 적합한 내진보강방법 등의 연구는 아직까지 초보적인 단계라고 할 수 있다. 이에 본 연구의 목적은 이러한 평가 기법을 적용한 국내 저층구조물의 내진성능을 평가하는 것이다. 저층구조물의 내진성능을 평가하기 위하여 1988년 내진설계가 도입되기 이전에 건립된 4층 규모의 학교구조물을 해석대상 구조물로 선정하였다. 대상 해석구조물의 내진성능평가는 일본의 내진성능 평가법을 참고하여 평가절차가 다소 복잡한 부분을 국내 실정에 맞게 개선시킨 내진화 우선도 평가방법과 정밀한 내진성능을 평하는 방법으로 세계적으로 널리 사용되고 있는 ATC-40 성능평가방법에서 등가단자유 모델로 변환 과정에서 등가유효감쇠 및 등가유효주기 산정 관계식의 문제점을 개선한 FEMA-440의 선형화 성능평가방법(Linearization Method)을 사용하여 구조물의 성능을 평가하였다. 내진 성능 평가를 위해 현재 전 세계적으로 널리 사용되고 있는 구조물 비선형 전용 해석 프로그램인 Perform-3D를 이용하여 해석을 수행하였다. 본 연구를 통해 기존 저층구조물로 선정한 학교구조물에 대한 내진성능을 평가한 결과, 내진화 우선도 평가법 및 FEMA-440의 내진성능 평가는 유사한 경향의 결과를 나타내었고, 두 평가결과를 요약하면 Y방향은 보와 기둥에 끼인 조적벽체의 영향으로 별도의 내진성능이 향상 보강이 필요없으나, X방향은 창문하부 허리 조적벽 등의 영향으로 다소 취성적인 내진성능을 보유하고 있어 충분한 내진성능 확보를 위한 추가적인 보강이 필요한 것으로 판단된다.
Journal of the Earthquake Engineering Society of Korea
/
v.9
no.3
s.43
/
pp.23-32
/
2005
Torsional behavior of eccentric structure under seismic leading may cause the stress and/or deformation concentration, which arouse the failure of the structure in an unexpected manner. This study suggests D-R relationship which shows the overall displacement and rotation of the system based on the ultimate displacement capacity of the each lateral load resistant member. Using the suggested D-R relationship and displacement spectrum, the seismic assessment is conducted and verified in comparison with the time history analysis result. Multi-level seismic assessment Is considered which takes multiple seismic hazard levels and respective performance levels into account. Finally, based on the seismic assessment result, seismic rehabilitation process is presented. In this research, two rehabilitation methods are considered. One is done by means of stiffening/strengthening the seismic resistant members, and the other is based on the member ductility. Especially, in the first method, to optimize the rehabilitation result, the rehabilitation problem is modeled as an optimization problem, and solved using BFGS quasi-Newton optimization method.
The Journal of the Convergence on Culture Technology
/
v.5
no.4
/
pp.439-444
/
2019
In this paper, the seismic performance evaluation of the subway lines 1~4 conducted from April 2010 to October 2013 for the existing structures that were not seismically designed based on the seismic design criteria of urban railways was studied. The detailed design of seismic reinforcement for the facilities requiring seismic reinforcement was summarized through the detailed design of the seismic reinforcement construction conducted from March to December 2018. As a result of the evaluation, 53.2km (total project cost of 322 billion won) of 141.5km of Lines 1~4 were considered to require seismic reinforcement, and finally, the company aims to secure a 100% earthquake-proof rate to withstand earthquake-scale 6.5 by 2020. This paper can be used as basic research data to evaluate and reinforce seismic performance of urban railways in the future.
The liquefaction of reclaimed land generally caused the harbor facilities to hazards. In Korea, the major harbor quay walls are gravity type and the gravity quay wall is not a good earthquake resistant structure. Recently, various earthquake resistant quay walls have been suggested, but the study on the efficiency of reinforced quay wall was not much performed. In this study, numerical analysis is carried out for performance evaluation of easily adoptable earthquake resistant quay walls. The results of numerical analysis are compared with shaking table test that is performed at the same cross-section.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.