• Title/Summary/Keyword: 내진구조

Search Result 1,420, Processing Time 0.029 seconds

Earthquake Resistance Design for a Typical Bridge Substructure (일반교량 하부구조의 내진설계)

  • Kook, Seung-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.283-288
    • /
    • 2011
  • For the earthquake resistance design designer should provide that structural yielding process is principally designed with the ductile failure mechanism. In order to get the ductile failure mechanism for typical bridges, pier columns yielding should occur before that of connections. However domestic bridge design with unnecessary stiff substructure leads to unnecessary seismic loads and makes it difficult to get the ductile failure mechanism. Such a problem arises from the situation that earthquake resistant design is not carried out in the preliminary design step. In this study a typical bridge is selected as an analysis bridge and design strengths for connections and pier columns are determined in the preliminary design step by carrying out earthquake resistant design. It is shown through this procedure that it is possible to get the ductile failure mechanism with structural members determined by other design.

Seismic Capacity Evaluation of Existing Structures Incorporating Damage Assessment (구조손상을 고려한 기설구조물의 내진성능평가)

  • Song, Jong Keol;Yi, Jin Hak;Lee, Dong Guen
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.543-553
    • /
    • 2004
  • This paper covered two related subjects: the use of the inverse modal perturbation technique to assess structural damage in existing structures; and the use of a seismic capacity evaluation to assess damaged structures, with the aid of the identified structural damage. The substructural identification and the Tikhonov regularization algorithm were incorporated for efficient damage assessment of complex and large frame structures. The seismic capacity of a damaged structure was evaluated by comparing the structure's seismic responses and seismic damage indices. The effectiveness of the proposed method has been investigated through the numerical simulation study for a twenty-story frame structure with undamaged and damaged cases, and also different earthquake excitations.

원자력發電所의 耐震設計용 入力 地震의 決定

  • 서정희
    • Journal of the KSME
    • /
    • v.20 no.5
    • /
    • pp.387-391
    • /
    • 1980
  • 일반적으로 내진 설계라 함은 지진에 의하여 발생된 지진동이 특정한 구조물에 작용할 때 이 지 진동의 경향하에서도 구조물의 정상적인 기능을 추진할 수 있도록 설계하는 것을 말하는 바, 원자력발전소의 내진설계에 있어서도 원칙적으로는 동일한 개념이나 실시하는 규정이 타구조물에 비하여 훨씬 엄격한 것이 다른 점이라 하겠다. 현재 우리나라의 경우 원자력 발전소는 1기(고리 #1)가 가동중이고 2기(월성 #1, 고리 #2)가 거의 완공단계에 있으며 7기(고리 #3, #4, 월성 #2, 계마 #1, #2, 부구 #1, #2)가 건설작업중인 바 이중 부구의 경우만 프랑스(\ulcorner)에서 건설 예정이고 기타는 모두 미국 및 카나다에서 건설하였거나 건설 예정이므로 따라서 그 설계에 있어서도 제 규정은 대체로 미국것을 준용하고 있는 형편이다. 그러므로 본고에서 는 미국에서 시행되고 있는 방법 또는 규정에 의거하여 내진설계용 입력지진에 대하여 설명하고자 한다. 내진설계에 입력 으로 사용되는 지진을 설계기준지진(design basis earthquake, DBE)이라고 통칭하며 이 지진은 미국 규정에 의하면 응답스펙트럼(response spectrum)으로 정의되게 되어 있으며 또한 이 응답 스펙트럼에 준하는 인공정인 지진의 시간기득(artificial time history)을 작성 또는 선정하여 이를 발전소 구조물의 내진 해석 및 내진 시험 입력으로 사용하게 되어 있다.

  • PDF

An Experimental Study on Seismic Performance Evaluation of Retrofitted Column of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재로 보강된 기둥의 내진성능평가 실험)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.21-30
    • /
    • 2013
  • As increasing number of large-size earthquake, the social interest of seismic retrofitting of RC structure is growing. Especially, the RC columns that are not reflected seismic design can not resist lateral loads by the earthquake. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. Thus, the emergency columns reinforcement method is needed. That have a fast construction time, do not cause damage to the column. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly, but in recent years, carbon fiber sheet taking advantage of FRP (Fiber Reinforced Polymer) is widely used. In this study, retrofitting effect of seismic performance of FRP seismic reinforcement, which is possible to emergency construction, was examined. Reinforced concrete specimens were constructed to experimental study. The seismic performence of specimes retrifitted with FRP seismic reinforcement were evaluated. As a result, the seismic performance of specimen reinforced with FRP seismic reinforcement has been improved.

Seismic Performance of Urban Structures with Various Horizontal Irregularities using Equivalent Static Analysis (다양한 수평비정형성을 갖는 도시구조물의 등가정적해석에 의한 내진성능분석)

  • Cui, Ji Long;Chey, Min-Ho;Kim, Sung-Il
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • With the change and development of modem architecture, architectural configurations are increasingly diversified and irregular. However, the building configurations without proper seismic considerations may cause severe damages under earthquake loads. Therefore, it is necessary to establish and implement more properly classified, specific and advanced conceptual seismic design strategies. This study explores the relationship between building configurations and seismic performance by adopting several horizontal building configurations with various re-entrant corners. For the clear comparison of five different horizontal configuration models, almost aspects of structural properties are equalized. The equivalent static analyses are conducted with the aim of understanding the characteristics of various re-entrant comers under standard earthquake loads. The seismic advantages of regular configuration model are clearly approved and the structural weak points at the re-entrant comers are investigated numerically and graphically.

Numerical Study for Seismic Strengthening of RC columns Using Fiber Reinforced Plastic Composite (기둥의 내진성능 향상을 위한 섬유보강 복합체의 적용성에 대한 해석적 연구)

  • Chang, Chun Ho;Kwon, Min Ho;Kim, Jin Sup;Joo, Chi Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.117-127
    • /
    • 2012
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. Fiber reinforced plastic composite material is one of strengthening material widely used to increase seismic performance of structures. It should have high stiffness as well as large ductility to provide best strengthening result. Thus selection of stiffener and fiber in composite is of important. In this study, the optimal combination of fiber and stiffener is selected with variety of tensile tests. In order to investigate performance of chosen composite material, several finite element analyses are performed with proposed FRP composite material for existing RC columns. It is discussed that the seismic performance of strengthened columns through the load-displacement relationship. It is shown that the proposed composite material can increase the strength as well as ductility of exiting RC columns.

Evaluation of Seismic Performance Factors of Diagrid Structural System (다이아그리드 구조 시스템의 내진성능계수 평가)

  • Kim, Kyoung-Hwan;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.229-239
    • /
    • 2010
  • As a new structural system, the diagrid system resists both gravity and lateral loads with diagonal columns. In current seismic design provisions, however, the response modification factor for a new structural system is not provided yet. ATC-63 provides a new methodology for defining various seismic performance factors, including the response modification factor. ATC-63 includes the collapse margin ratio in modifying the response modification factor, which can vary with many structural systems. In this paper, a non-linear static analysis and a dynamic analysis were conducted for four different diagrid models with 4-to 36-story heights. From these analyses, the response modification factor of the diagrid system was evaluated.

Optimal Seismic Rehabilitation of Structures Using Probabilistic Seismic Demand Model (확률적 지진요구모델을 이용한 구조물의 최적 내진보강)

  • Park, Joo-Nam;Choi, Eun-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.1-10
    • /
    • 2008
  • The seismic performance of a structure designed without consideration of seismic loading can be effectively enhanced through seismic rehabilitation. The appropriate level of rehabilitation should be determined based on the decision criteria that minimize the anticipated earthquake-related losses. To estimate the anticipated losses, seismic risk analysis should be performed considering the probabilistic characteristics of the hazard and the structural damage. This study presents the decision procedure in which the probabilistic seismic demand model is utilized for the effective estimation and minimization of the total seismic losses through seismic rehabilitation. The probability density function and the cumulative distribution function of the structural damage for a specified time period are established in a closed form, and are combined with the loss functions to derive the expected seismic loss. The procedure presented in this study could be effectively used for making decisions on the seismic rehabilitation of structural systems.

Seismic Retrofit of RC Exterior Beam-Column Joints Strengthened with CFRP (CFRP를 이용한 비내진 철근콘크리트 외부 보-기둥 접합부의 내진 보강)

  • Kim, Min;Lee, Ki-Hak;Lee, Jae-Hong;Woo, Sung-Woo;Lee, Jung-Weon
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.729-736
    • /
    • 2006
  • It has been shown that many Reinforced Concrete(RC) structures designed without seismic details have experienced brittle shear failures in the beam-column joint area and resulted in large permanent deformations and structural collapse. In this study, experimental investigations into the performance of exterior reinforced concrete beam-column joints strengthened with the carbon fiber-reinforced polymer(CFRP) under cyclic loading were presented. The CFRP has been applied by choosing different combinations and locations to determine the effective way to improve structural performances of joints. Eight beam-column joints were tested to investigate behaviors of each specimen under cyclic load and to compare performances of seismic retrofit. According to the experimental study, the retrofit strengthened with the CFRP provides significant improvements of flexural capacity and ductility of beam-column joints originally built without seismic details.