As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. Fiber reinforced plastic composite material is one of strengthening material widely used to increase seismic performance of structures. It should have high stiffness as well as large ductility to provide best strengthening result. Thus selection of stiffener and fiber in composite is of important. In this study, the optimal combination of fiber and stiffener is selected with variety of tensile tests. In order to investigate performance of chosen composite material, several finite element analyses are performed with proposed FRP composite material for existing RC columns. It is discussed that the seismic performance of strengthened columns through the load-displacement relationship. It is shown that the proposed composite material can increase the strength as well as ductility of exiting RC columns.
Keywords
Seismic retrofitted; FRP composite; Fiber; Column retrofitted; Push-Over Analysis(NSA); Finite element;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 권민호, 정우영, 정재훈, "비부착 철근 여부에 따른 RC 보-기둥 저합부의 성능평가", 한국구조물진단학회 논문집, 제15권 6호, 2011, pp.201-211.
2 심종성, 김규선, "건설 분야에서의 FRP활용", 콘크리트학회지, 제12권, 6호, 2000, pp.37-43.   과학기술학회마을
3 유영찬, 최기선, 강인석, 김긍환, "구조보강용 FRP 복합체의 역학적 특성치 분석을 위한 인장시험방법 평가 연구", 한국구조물진단학회 논문집, 제12권 1호, 2008, pp.73-80.   과학기술학회마을
4 조하나, 신영수, "유리섬유 보강재의 특성 및 적용", 구조물진단학회지, 제2권 3호, 1998.
5 ABAQUS, Dassault Systems Simulia Corp. (2011). Abaqus Analysis User's Manual. Version 6.10, 2011.
6 ACI Committee 437, "Load Tests of Concrete Structures : Methods, Magnitude, Protocols, and Acceptance Criteria (ACI 437.1R-07)".
7 ASTM, D638, "Tensile Properties of Plastic Materials with Automatic Extensometry", 2008.
8 C. M. Renaud, M. E. Greenwood, "Effect of Glass Fibers and Environments on LonTerm Durability of GFRP Composites", RP-Asia 2002, Kuala-Lumpur.
9 L. C. Hollaway and P. R. Head, "FRP strengthening and repair of reinforced concrete systems. Advanced Polymer Composites and Polymers in the Civil Infrastructure", 2001, pp.109-159.
10 Lee, J. and Fenbas, G. L., "Plastic-damage midel for cyclic loading of concrete structures", Journal of Engineering Mechanics, ASCE, vol. 124, 1998, pp.892-900.   DOI   ScienceOn
11 Lubliner, J., Oliver, J., Oller, S. and Onate, E., "A plastic-damage model for concrete", Int. J. Solids Struct., vol. 25, No. 3, 1989, pp.299-326.   DOI   ScienceOn
12 M. Kwon, P. B. Shing, C. Mallare and J. Restrepo, "Seismic Resistance of RC Bent Caps in Elevated Mass Transit Structures", Earthquake Spectra vol. 27, 2011, pp.67-88.   DOI   ScienceOn