• Title/Summary/Keyword: 내부 순환 손실

Search Result 28, Processing Time 0.024 seconds

A Model for Liquid Circulation Velocity in Airlift Reactors (공기부양반응기 내에서의 액체순환속도를 위한 모델)

  • Keun Ho Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.446-455
    • /
    • 2023
  • A mathematical model for predicting the liquid circulation velocity in an airlift reactor was developed based on the mechanical energy balance of the fluid circulation loop. The model considered the energy loss due to a 90° turn, the energy loss due to friction, and the energy loss due to the change in cross-sectional area at each part of the reactor. The model that separately considered the loss coefficients related to friction, direction change, and cross-sectional area change was able to predict the liquid circulation velocity better than the previous model using lumped parameters. The liquid circulation velocity was measured by the tracer pulse method. Most of our experimental results obtained in external-loop airlift reactors, which had the top and bottom connecting pipes, as well as other investigators' results obtained in various types of airlift reactors, were well predicted by the developed model with an error within 20%. Useful empirical equations for the loss coefficient related to the 90° turn of the circulating fluid were obtained in external and internal-loop airlift reactors and used to predict the liquid circulation velocity.

Problems and solution for the circulation current at the neutral line in the 22.9kV CNCV cable distribution system. (전력기술.정보-22.9kV 배전계통 CNCV 케이블 동심중성선에 발생하는 순환전류 문제점 및 대책)

  • 전명수
    • Electric Engineers Magazine
    • /
    • s.304
    • /
    • pp.22-25
    • /
    • 2007
  • 우리 나라의 전력 계통에 있어 22.9kV-y 배전 방식은 변전소로부터 배전 선로를 통해 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전 선로의 중성선을 일정 구간 마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 이러한 다중 접지방식은 동심 중성선을 대지에 직접 접지하기 때문에 지락 사고시 건전상의 전압 상승이 적어 전력 설비의 절연 및 지락 전류의 검출이 용이하고 보호 계전기 등이 신속하게 동작한다. 계통 사고 등으로 인하여 동심 중성선의 전위가 상승되는 것을 방지하고자 케이블 접속 구간마다 동심 중성선을 일괄 접지하는 방식으로 배전 계통을 운영하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전위 상승을 일정값 이하로 제한하여 안전하게 유지하기 위해서이다. 그러나 지중 배전 선로에서 각 상(A, B, C상)의 부하가 불평형이 되는 것은 물론 평형일 경우에도 동심 중성선에는 부하 전류에 41.5%(전력구)-51.6%(관로)의 동심 중성선 순환 전류가발생되고 있기 때문에 순환전류로 인한 손실이 도체 손실의 76%에 달하며, 이러한 손실 전력으로 케이블의 내부 온도가 상승되어 케이블의 전류 용량이 관로의 경우 20% 정도 감소하게 된다. 본 연구는 이같은 문제점을 해결하는데 목적이 있다.

  • PDF

Problems and solution for the circulation current at the neutral line in the 22.9kV CNCV cable distribution system. (22.9kV 배전계통 CNCV 케이블 동심중성선에 발생하는 순환전류 문제점 및 대책)

  • Jeon, Myung-Soo;Song, Joong-Ho;Gu, Sung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.431-433
    • /
    • 2006
  • 우리나라의 전력 계통에 있어, 22.9kV-y 배전 방식은 변전소로부터 배전 선로를 통해, 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전 선로의 중성선을 일정 구간마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 이러한 다중 접지방식은 동심 중성선을 대지에 직접 접지하기 때문에 지락 사고시 건전상의 전압 상승이 적어 전력 설비의 절연 및 지락 전류의 검출이 용이하고 보호 계전기 등이 신속하게 동작한다. 계통 사고 등으로 인하여 동심 중성선의 전위가 상승되는 것을 방지하고자 케이블 접속 구간마다 동심 중성선을 일괄 접지하는 방식으로 배전 계통을 운영하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전의 상승을 일정값 이하로 제한하여 안전하게 유지하기 위해서이다. 그러나 지중 배전 선로에서 각 상(A,B,C상)의 부하가 불평형이 되는 것은 물론 평형일 경우에도 동심 중성선에는 부하 전류에 41.5%(전력구)$\sim$51.6%(관로)의 동심 중성선 순환 전류가 발생되고 있기 때문에 순환전류로 인한 손실이 도체 손실의 76%에 달하며, 이러한 손실전력으로 케이블의 내부 온도가 상승되어 케이블의 전류 용량이 관로의 경우 20% 정도 감소하게 된다. 본 연구는 이같은 문제점을 해결하는데 목적이 있다.

  • PDF

A Study on Determining the Transmission Loss of Water-Borne Noise Silencer in a Sea-Connected Piping System (해수연결 배관계 소음감소기의 투과손실 측정에 관한 연구)

  • Park, Kyung-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.286-292
    • /
    • 2007
  • The dominant source of noise in a sea-connected piping system is usually due to a seawater cooling pump which circulates seawater to operate onboard equipments normally, and so its water-borne noise with some tonal frequencies should be reduced using proper silencers. In order to obtain the transmission loss of water-borne noise silencers experimentally the present paper suggests a transfer function technique that acoustic wave in the piping system is decomposed into its incident and transmitted components when the reflection at the termination of the system exists. Good agreement in the interested frequency range with theory and the proposed technique shows the validity of the technique.

A Study on the Single-phase Power converter having a Power Circulating Control Technique (전력순환제어기술을 가진 단상 전력변환기에 대한 연구)

  • Baik, Seung-Jun;Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.220-221
    • /
    • 2013
  • UPS 부하시험시 또는 DC 전압원 방전 시험시에 사용되는 일반 저항 또는 역률 부하 시험기를 사용하지 않고 UPS 내부 역변환부 출력전원을 출력 스위치와 바이패스 스위치를 통해서 순변환부 입력전원에 재공급함으로써 시험용 저항부하기 또는 역률 부하 시험기와 같이 모든 에너지를 열로 소비하지 않고 순변환부 측으로 재 순환시켜서 UPS 부하시험 시 입력 전원용량이 UPS 최소 내부 손실분만으로도 이미 현장 설치 및 운영 중인 UPS에서도 별도의 부하 시험기 및 시험용 케이블을 이동, 설치하지 않고 주기적인 UPS 점검 시, 적용 가능한 에너지 절감형 부하시험기법에 관해 연구하였다.

  • PDF

An Elimination Method Of the Circulating Current Flowing into Coaxial-Neutral Lines in 22.9[kV] CNCV Underground Cable Systems (22.9[kV] 지중배전계통케이블의 동심중성선에 흐르는 순환전류의 제거방안 및 효과)

  • Jeon, Myung-Su;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • In 22.9[kV]-y distribution systems, underground cables are provided with multiple-point ground in which each coaxial-neutral line of the distribution cable lines(A, B, C phases) is 3-wire common grounded. In the underground cable distribution systems, circulating current flows in the coaxial-neutral lines and its magnitude amounts to about $40{\sim}50[%]$ load currents, even though loads are balanced. Power loss due to the circulating current consequently reaches to about 76[%] total losses occurred in all conductor lines. This power loss provokes additional temperature rise of the underground cable lines and finally results in 20[%] reduction of the current capacity of the cables. This paper presents a new ground method to overcome such a problem. The proposed method eliminates the circulating current flowing in the coaxial-neutral line effectively. Measurement results confirmed from the practical site-test show validity and effectiveness of this research.

Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan (원자력발전소 복수기 수실 차단밸브 설치 영향 평가)

  • Lee, Sun-Ki
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2020
  • Because there are no isolation valves in condensate system of nuclear power plants, circulating water pump was shutdown for the condenser repair. When circulating water pump was shutdown, power plant output decreased about 45%. These output decreasing can minimize by establishing isolation valves. In this paper, evaluated effect to flow conditions change of condensate system, structural integrity of system, condenser pressure of in case of establish isolation valves to condensate system. Results of the evaluation, the flow rate due to the installation of the isolation valve decreased 0.3% when the valve was fully opened and 4.5% when fully closed. In addition, it was found that the vacuum degree of the condenser decreased with decreasing flow rate, but the integrity of the system was maintained.

Design of gas suspension absorber to improve desulfurization efficiency

  • Hwang, Woohyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.2
    • /
    • pp.189-195
    • /
    • 2020
  • In this study, the inlet duct and guide vane of the gas floating absorption tower were redesigned to improve the desulfurization efficiency so that the exhaust gas can be uniformly introduced into the absorption tower. In order to reduce the sulfur oxide pollutants among the main sources of air pollutants in industrial boilers, the existing equipment is redesigned and solved. For this purpose, change the exhaust gas, the slurry and recycling the adsorbent to improve the removal efficiency of SOx component in the exhaust gas inside the gas floating absorption tower so as to uniformly contact. And the initial design value and CFD value for the pressure loss from the boiler outlet to the gas floating absorption tower outlet are verified. Also, the velocity distribution of the exhaust gas, the concentration distribution of the recycled adsorbent, the liquid slurry behavior, and the pressure loss were compared. The results confirmed that the desulfurization efficiency was improved because the pressure loss from the boiler outlet to the absorption tower outlet was reduced and the deflection of the exhaust gas was minimized.

An effect of applying new separate commongrounding technology for Underground distribution line (지중배전선로 비일괄공동접지기술 시행 효과에 대한 연구)

  • Lee, Jae-Bong;Jeon, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.135-139
    • /
    • 2008
  • 우리 나라의 전력 계통은 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 22.9kV-y 배전 방식으로 CNCV 지중 케이블로 전력을 공급하고 있으며, 선로 운영상 케이블의 동심중성선을 일정 구간 마다 3선 일활 공동 접지하는 다중 접지방식을 채택하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전위 상승을 일정 값 이하로 제한함과 동시에 보호계전기의 동작을 원활히 하기 위함이다. 그러나 지중 배전 선로에서 각 상(A,B,C상)의 부하가 불평형이 될 때는 물론 평형일 경우에도 동심 중성선에는 부하 전류에 비례하는 동심 중성선 순환 전류가 발생되고 있기 때문에 불필요한 손실 전력이 발생하며, 이러한 손실 전력으로 케이블의 내부 온도가 상승되어 케이블의 송진용량이 감소하게 된다. 따라서 2006년 7월12일${\sim}$14일 대한전기학회 하계학술대회에 이에 대한 문제점과 대책으로 비일괄공동접지에 관한 연구 논문을 발표 한 바 있으며, 본 인구는 일곽공동접지방식의 기능을 저해하지 않으면서 비일관공동접지기술을 안전하게 시행하는 방법과 예상되는 문제점 및 시행효과 검증에 관한 연구이다.

  • PDF

Performance analysis of mixed-flow fans considering the low flow characteristics (저유량 특성을 고려한 사류 송풍기의 성능 해석)

  • Oh, Hyoung Woo;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.110-115
    • /
    • 2000
  • The mean streamline analysis using the empirical loss correlations has been developed for performance prediction of industrial mixed-flow fan impellers in the present study. New simple, but effective, models for the additional Euler input work characteristic and an internal recirculation loss due to internal flow reversal under the low flowrate conditions are proposed in this paper. Comparison of overall performance predictions with six sets of test data of mixed-flow fans is accomplished to demonstrate the accuracy of the proposed models. Predicted performance curves by the present set of loss models agree fairly well with experimental data for a variety of mixed-flow fan impellers over the entire operating conditions. The prediction method presented herein can be used efficiently in the conceptual design phase of mixed-flow fan impellers.

  • PDF