• Title/Summary/Keyword: 내부보강형 모델

Search Result 9, Processing Time 0.024 seconds

A Study on Behavioral Characteristics of Inner Reinforced CFT Column-to-Foundation Connections (내부보강형 CFT 기둥 기초 연결부의 거동특성에 대한 연구)

  • Kim, Hee-Ju;Ham, Jun-Su;Chung, Jin-Il;Hwang, Won-Sup
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.4
    • /
    • pp.36-43
    • /
    • 2014
  • In this study, circular sectional concrete-filled tube(CFT) column-to-foundation connections were numerically investigated in order to improve their structural details. A inner reinforced specimen with high-tension bolts and inner deformed bars was adopted from a previous experimental study to make the numerical model. The validity of the numerical method was verified through comparing the experimental results with the analysis's ones. In order to optimize design variables about the inner reinforced model, a number of numerical analyses were conducted for various variables. Finally, this study suggested the optimum variables about the reinforced circular sectional CFT column-to-foundation connections.

Waterborne Noise Prediction of the Reinforced Cylinderical Shell Using the SEA Technique (SEA 기법을 이용한 보강 원통형 셀의 수중방사소음 해석)

  • 배수룡;전재진;이헌곤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.107-112
    • /
    • 1992
  • 선박 내부에 탑재된 추진 기계류에서 발생되는 진동은 마운트 Deck을 통하 여 선체에 전달되어 수중으로 전파된다. 기계류에 의해 발생되는 수중방사소 음을 감소시키기 위해서는 선체로 전달된 진동수준 및 수중방사소음 예측이 우선 중요하다. 수중방사소음 예측 방법으로 FEM과 BEM에 의한 저주파수 대역 예측, 전달함수에 의한 실험적 예측, SEA(Statistical Energy Analysis) 기법을 이용한 고주파수 대역 예측으로 나눌 수 있다. R.H.Lyon 등에 의해 발전된 SEA 기법은 항공기, 선박등 복잡한 구조물의 고주파수 대역 진동해 석에 널리 이용되고 있다. SEA 기법의 선박에 대한 적용은 소형선박의 기계 류에서 발생되는 진동에 의한 선체 진동수준 및 수중방사소음 해석 등에 적 용되고 있다. 본 연구에서는 보강 원통형 셀 모델에 대한 수중방사소음을 SEA 기법을 이용하여 예측하고 실험을 통하여 검증하였다.

  • PDF

Parametric Analysis on Ultimate Behavior of Cylindrical GFRP Septic Tank (원통형 GFRP 개인하수 처리시설의 극한거동에 대한 매개변수해석)

  • Kim, Sung Bo;Cho, Kwang Je
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1337-1347
    • /
    • 2013
  • The parametric analysis on ultimate behavior of buried cylindrical GFRP(Glass Fiber Reinforced Polymer) septic tank was presented. Two kinds of F.E. analysis model(soil-spring model and 3D full model) was constructed. The ultimate behavior of septic tank was investigated according to the size of stiffened steel ring and properties of underground soil. Ramberg-Osgood model and Druker-Prager model were used for material nonlinear characteristics of GFRP septic tank and soil, respectively. The diameter and thickness of stiffened steel ring inside septic tank, elastic modulus and internal friction angle of soil were selected for parametric variables. The ultimate behavior of septic tank, load-displacement, axial and hoop strain, were calculated and investigated.

Analysis of Reinforcement Effect of Steel-Concrete Composite Piles by Numerical Analysis (I) - Material Strength - (수치해석을 이용한 강관합성말뚝의 보강효과 분석 (I) - 재료 강도 -)

  • Kim, Sung-Ryul;Lee, Juhyung;Park, Jae-Hyun;Chung, Moonkyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.259-266
    • /
    • 2009
  • The steel pipe of steel-concrete composite piles increases the pile strength and induces the ductile failure by constraining the deformation of the inner concrete. In this research, the numerical models and the related input parameters were analyzed to simulate the axial load-movement relations, which were obtained from the compression loading tests for the cylindrical specimens of the steel pipe, the concrete, and the steel-concrete composite. As the results, the behavior of the steel pipe was simulated by the von-Mises model and that of the concrete by the strain-softening model, which decreases cohesion and dilation angles as the function of plastic strains. In addition, the reinforcing bars in the concrete were simulated by applying the yielding moment and decreasing the sectional area of the bars. The applied numerical models properly simulated the yielding behavior and the reinforcement effect of the steel-concrete composite piles. The parametric study for the real-size piles showed that the material strength of the steel-concrete composite pile increased about 10% for the axial loading and about 20~45% for the horizontal loading due to the reinforcement effect by the surrounding steel pipe pile.

An Experimental Study on Geotextile Effects as Reinforcement and Vertical Drain Materials (보강재(補强材) 및 배수촉진재(排水促進材)로서 Geotextile 의 효과(効果)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Soo Il;Yoo, Ji Hyeung;Cho, Sam Deok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.39-47
    • /
    • 1982
  • Geotextile effects as reinforcement and vertical drain materials are studied through the laboratory model embankments on weak clays. The experiments are carried out in four stages; no woven fabrics between clay-crushed stone boundary, fabrics between boundary with no initial pretensioning of fabrics, and fabrics between boundary with two different initial pretensionings of fabrics. In all stages, vertical drains utilizing non-woven fabrics are installed in the clay layer in square pattern to accelarate the consolidation. The experimental model has plane dimensions of $32cm{\times}330cm$. The height for the clay container is 60 cm. The 47 cm height of crushed stone embankment is constructed over the 50 cm deep clay layer. The time dependent pore pressures are measured utilizing the 8 piezometers installed symmetrically on both sides of the wall at different heights. The time dependent deformations are measured utilizing the LED indicating lamp matrix inserted in the crushed stone embankment and the dialgauges put on top of the clay layer where the crushed stones are not laid. The measurements are carried out for 10 days which is equivalent to the time required for the primary consolidation. Through the experimental study, an analytical procedure is developed to predict the time dependent embankment settlement even if the top of the clay layer is reinforced with woven fabrics. This can be done through measuring the maximum pore pressures developed in the clay layer and comparing with the theoretical maximum pore pressures when no reinforcing fabrics are employed.

  • PDF

Design Approach for Boundary Element of Flexure-Governed RC Slender Shear Walls Based on Displacement Ductility Ratio (휨 항복형 철근콘크리트 전단벽의 경계요소설계를 위한 변위연성비 모델제시)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.687-694
    • /
    • 2014
  • This study established a displacement ductility ratio model for ductile design for the boundary element of shear walls. To determine the curvature distribution along the member length and displacement at the free end of the member, the distributions of strains and internal forces along the shear wall section depth were idealized based on the Bernoulli's principle, strain compatibility condition, and equilibrium condition of forces. The confinement effect at the boundary element, provided by transverse reinforcement, was calculated using the stress-strain relationship of confined concrete proposed by Razvi and Saatcioglu. The curvatures corresponding to the initial yielding moment and 80% of the ultimate state after the peak strength were then conversed into displacement values based on the concept of equivalent hinge length. The derived displacement ductility ratio model was simplified by the regression approach using the comprehensive analytical data obtained from the parametric study. The proposed model is in good agreement with test results, indicating that the mean and standard deviation of the ratios between predictions and experiments are 1.05 and 0.19, respectively. Overall, the proposed model is expected to be available for determining the transverse reinforcement ratio at the boundary element for a targeted displacement ductility ratio.

Design of the Blade-Type Optical Bench for Earth Observation Satellite (지구관측위성의 블레이드형 광학탑재체 지지구조물 설계)

  • Kim, Kyung-Won;Kim, Jin-Hee;Rhee, Ju-Hun;Jin, Ik-Min;Kim, Jong-Wo;Park, Jong-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.11
    • /
    • pp.88-94
    • /
    • 2005
  • This paper is a study on the blade-type optical bench satisfying stiffness and thermal pointing error requirements for earth observation satellite. According to shape requirements, optical bench is designed. Because it does not satisfy the stiffness requirement, the stiffener is added on the outer/inner area of optical bench. But it does not meet the thermal pointing error requirement. So symmetrical structure is suggested with platform support structure attached on the upper/lower part of platform. Although it has better value than previous case, it still does not meet the thermal pointing error requirement. Based on the results of prior cases, optical bench finally designed, which satisfied both the stiffness and thermal pointing error requirements. Next conclusions follow from this design. It is efficient to increase thickness of platform facesheet, add stiffener and increase blade number to raise stiffness. It is effective to connect component consisting of same material and design optical bench having symmetrical structure to lower thermal pointing error.

Finite Element Analysis on Reinforced Concrete Filled PHC Pile with Ring Type Composite Shear Connectors (링형 합성 전단연결재를 적용한 철근 콘크리트 충전 PHC말뚝의 유한요소해석)

  • Kim, Jeong-Hoi;Lee, Doo-Sung;Park, Young-Shik;Min, Chang-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.249-257
    • /
    • 2017
  • The purpose of this study was to contribute to the field application cost effectively and reasonably by developing the functional piles that make up for the defects of PHC piles. CFP (Concrete Filled Pretensioned Spun High Strength Concrete Pile with Ring type Composite shear connectors) piles developed in this study increases the compressive stress through enlarged cross section by rearranging composite shear connectors and filling the hollow part of PHC pile with concrete. And it improved shear and bending performance placing the rebar (H13-8ea) within the PHC pile and the hollow part of PHC pile of rebar (H19-8ea). In addition, the composite shear connectors were placed for the composite behavior between PHC pile and filled concrete. Placing Rebars (H13-8ea) of PHC pile into composite shear connector holes are sleeve-type mechanical coupling method that filling the concrete to the gap of the two members. Nonlinear finite element analyzes were performed to verify the performance of shear and bending moments and it deduced the spacing of the composite shear connectors. Through a various interpretation of CFP piles, it's proved that the CFP pile can increase the shear and bending stiffness of the PHC pile effectively. Therefore, this can be utilized usefully on the construction sites.

Analysis Study on Fire Performance with Internal Anchored Concrete Filled Steel Tube Columns According to Percent of Steel-Fibers (강섬유 콘크리트 혼입율에 따른 내부앵커형 콘크리트 충전기둥 내화성능에 관한 해석적 연구)

  • Kim, Sun Hee;Yom, Kong Soo;Kim, Yong Hwan;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Concrete filled steel tube system has two major advantages. First, the confinement effect of steel tube improves the compressive strength of concrete. Second, the load capacity and deformation capacity of members are improved because concrete restrains local buckling of steel tube. It does, however, involve workability problem of using stud bolts or anchor bolts to provide composite effect for larger cross-sections. While the ribs inside the columns are desirable in terms of compressive behavior, they cause the deterioration in load capacity upon in-plane deformation resulting from thermal deformation. Since the ribs are directly connected with the concrete, the deformation of the ribs accelerates concrete cracking. Thus, it is required to improve the toughness of the concrete to resist the deformation of the ribs. Welding built-up tubular square columns can secure safety in terms of fire resistance if the problem are solved. This study focuses on mixing steel fiber in the concrete to improve the ductility and toughness of the columns. In order to evaluate fire resistance performance, loaded heating test was conducted with 8 specimens. The behavior and thermal deformation capacity of the specimens were analyzed for major variables including load ratio. The reliability of heat transfer and thermal stress analysis model was verified through the comparison of the results between the test and previous study.