주복수기 냉각해수배관의 직각 엘보 내부유동특성에 관한 연구 (Experimental study of internal flow field about 90degree elbow for cooling seawater pipe at the main condenser)

  • 오승진;조대환;봉태근;김옥석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.152-153
    • /
    • 2012
  • While engine room arranging pipe which is used from the vessel, It measured the internal flow of 90 degree elbow which is used from the main condenser. Fluid flow in elbow of 90 degree is measured by PIV and Dewetron system. The Reynolds number adopts 50000 and experimental study of flow field in the elbow.

  • PDF

곡관의 손상압력에 미치는 내부 감육결함의 영향 평가 (An Evaluation of the Effect of Internal Thinning Defect on the Failure Pressure of Elbow)

  • 김진원;김태순;박치용
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.28-34
    • /
    • 2003
  • In the present study, three-dimensional finite element analysis was performed to investigate the effects of internal wall thinning defect on the failure pressure of elbow in the piping system and to develop the failure pressure evaluation model. From the results of finite element analysis, the failure pressure was derived by employing local stress criteria, and the effects of thinning location, bend radius, and defect geometry on the failure pressure of internally wall thinned elbow were investigated. Also, based on these investigations and previous model developed to estimate the failure pressure of elbow with an external pitting defect, the failure pressure evaluation model to be applicable to the elbow containing an internal thinning defect was proposed and compared with the results of finite element analysis. The failure pressure calculated by the model agreed well with the results of finite element analysis.

전단간섭법을 이용한 배관 순환 시스템에서의 압력용기 내부결함 및 면외변형 측정 (Measurement of Inner Defects and out of Plane Deformation of Pressure Vessel in Piping of Circulation System Using Shearography)

  • 강찬근;김현호;정현일;최태호;정현철;김경석
    • 비파괴검사학회지
    • /
    • 제34권5호
    • /
    • pp.349-355
    • /
    • 2014
  • 다양한 산업분야에서 사용되는 압력용기는 발전설비의 70~80%를 구성하는 설비구조물로써 유속에 의한 감육결함 현상이 발생할 수 있으며 내부결함 측정이 설비의 안전진단 평가에 중요한 요소가 된다. 본 논문에서는 광계측 응용 비파괴검사 기술인 전단간섭법을 이용하여 압력용기의 비접촉 비파괴평가를 통한 발전설비의 안정성 확보와 신뢰성 향상에 있다. 이를 검증하기 위하여 압력용기에 임의의 결함을 가공하여 배관 순환 시스템을 적용한 내부의 온도 변화와 압력 변화에 따른 내부결함 계측 및 면외 변형량 계측에 대하여 실험과 해석을 수행하였다. 본 연구를 통한 결함의 존재 유무를 구분할 수 있도록 하는 가장 중요한 요소는 결함 두께, 폭 및 결함길이라 할 수 있으며 결함 두께, 폭, 길이가 커질수록 변형랑도 커짐을 확인할 수 있었다. 따라서 전단간섭법을 이용한 압력용기의 내부결함을 사전에 측정하여 배관의 신뢰성과 건전성을 확보하는데 주요할 것으로 보인다.

내압과 굽힘의 복합하중에서 내부 감육배관의 손상기준 (Criterion for Failure of Internally Wall Thinned Pipe Under a Combined Pressure and Bending Moment)

  • 김진원;박치용
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.52-60
    • /
    • 2002
  • Failure criterion is a parameter to represent the resistance to failure of locally wall thinned pipe, and it depends on material characteristics, defect geometry, applied loading type, and failure mode. Therefore, accurate prediction of integrity of wall thinned pipe requires a failure criterion adequately reflected the characteristics of defect shape and loading in the piping system. In the present study, the finite element analysis was performed and the results were compared with those of pipe experiment to develop a sound criterion for failure of internally wall thinned pipe subjected to combined pressure and bending loads. By comparing the predictions of failure to actual failure load and displacement, an appropriate criterion was investigated. From this investigation, it is concluded that true ultimate stress criterion is the most accurate to predict failure of wall thinned pipe under combined loads, but it is not conservative under some conditions. Engineering ultimate stress estimates the failure load and displacement reasonably for al conditions, although the predictions are less accurate compared with the results predicted by true ultimate stress criterion.

금속배관 건전성 감시를 위한 배열형 펄스와전류 탐촉자의 설계 및 배열신호 제안 (Design and Array Signal Suggestion of Array Type Pulsed Eddy Current Probe for Health Monitoring of Metal Tubes)

  • 신영길
    • 비파괴검사학회지
    • /
    • 제35권5호
    • /
    • pp.291-298
    • /
    • 2015
  • 본 논문에서는 외부에서의 탐촉자 스캐닝이 어려운 금속배관의 긴 축방향 결함이나 두께감육 등과 관련된 건전성을 감시하기 위하여 펄스와전류 신호의 피크치와 피크(발생)시간을 이용하는 배열형 탐촉자를 제안하였다. 탐촉자는 관을 따라 외삽형 코일들을 배열하고, 금속배관의 상태를 반영하는 자계는 와전류에 의해 생성되는 자계이므로 원천자계가 직접적으로 센서신호에 영향을 미치는 것을 막기 위하여 코일의 외부를 페라이트로 차폐하였다. 여자코일과 센서코일은 자동적으로 연속해서 위치를 이동하게 되므로 사람이 직접 탐촉자를 주사할 필요는 없다. 두 코일의 위치가 고정되어 있을 때 센서에서 감지되는 펄스와전류 신호에서 피크치와 피크시간을 추출하고, 모든 위치에서 추출되는 이 데이터들을 축적하여 배열형 피크치 신호와 배열형 피크시간 신호를 생성하였다. 수치 모사는 시간영역은 후향차분법으로, 공간은 유한요소법을 사용하여 수행되었다. 모사 결과는 결함의 깊이나 길이가 증가함에 따라 펄스와전류 신호에서 피크치가 증가하며 피크는 더 일찍 나타난다는 것을 보여 주었으며, 이를 활용하여 본 연구에서 제안한 배열신호들은 배열형 탐촉자 내부에서 결함의 깊이나 길이 변화뿐만 아니라 결함의 위치를 반영하는데에도 탁월함을 증명하였다.