Criterion for Failure of Internally Wall Thinned Pipe Under a Combined Pressure and Bending Moment

내압과 굽힘의 복합하중에서 내부 감육배관의 손상기준

  • Kim, Jin-Weon (Department of Nuclear Engineering, Chosun University) ;
  • Park, Chi-Yong (Nuclear Laboratory, Korea Electric Power Reaerach Institute(KEPRI))
  • 김진원 (조선대학교 원자력공학과) ;
  • 박치용 (한전전력연구원 원자력연구실)
  • Published : 2002.12.01

Abstract

Failure criterion is a parameter to represent the resistance to failure of locally wall thinned pipe, and it depends on material characteristics, defect geometry, applied loading type, and failure mode. Therefore, accurate prediction of integrity of wall thinned pipe requires a failure criterion adequately reflected the characteristics of defect shape and loading in the piping system. In the present study, the finite element analysis was performed and the results were compared with those of pipe experiment to develop a sound criterion for failure of internally wall thinned pipe subjected to combined pressure and bending loads. By comparing the predictions of failure to actual failure load and displacement, an appropriate criterion was investigated. From this investigation, it is concluded that true ultimate stress criterion is the most accurate to predict failure of wall thinned pipe under combined loads, but it is not conservative under some conditions. Engineering ultimate stress estimates the failure load and displacement reasonably for al conditions, although the predictions are less accurate compared with the results predicted by true ultimate stress criterion.

Keywords

References

  1. Michel, F., Reck, H., and Schulz, H,. 'Experience with piping in Gennan NPPs with Respect to Ageing-Related Aspects.,' Nucl. Eng. & Des., Vol. 207, pp. 307-316, 2001 https://doi.org/10.1016/S0029-5493(01)00339-9
  2. Chexal, B., Horowitz, J., Dooley, B., Millett, P., Wood, C, and Jones, R, 'Flow-Accelerated Corrosion in Power Plant,' EPRI/TR-106611-R2,1998
  3. Virginia Electric and Power Co., 'Suny Unit 2 Reactor Trip and Feedwater Pipe failure Report,' 1989
  4. Japan Atomic Energy Research Institute, 'Technical Reprt on the Piping Reliability Tests at the Japan Atomic Energy Research Institute (Japanese),' JAERI-M, 93-074, pp. 104-115, 1993
  5. Wilkowski, G., Stephens, D., Krishnaswamy, P., Leis, B., and Rudland, D., 'Progress in Development of Acceptance Criteria for Local Thinned Areas in Pipe and Piping Components,' Nucl. Eng. & Des., Vol. 195, pp. 149-169, 2000 https://doi.org/10.1016/S0029-5493(99)00245-9
  6. 김진원, 박치용, 김범년, '내압과 굽힘하중하에서 감육배관의 국부허용두께 평가,' 대한기계학회논문집 A권, Vol. 25, No. 1. pp. 81-88, 2001
  7. Miyazaki, K., Kanno, S., Ishiwata, M., Hasegawa, K., Ahn, S. H., and Ando, K., 'Fracture Behavior of Carbon Steel Pipe with Local Wall Thinning Subjected to Bending Load,' Nucl. Eng. & Des, Vol. 191, pp. 195-204, 1999 https://doi.org/10.1016/S0029-5493(99)00141-7
  8. American Society of Mechanical Engineer, ASME B&PV Sec.XI, Div.l, ASME Code Case N-597, 'Requirement for Analytical Evaluation of Pipe Wall Thinning.,' 1998ed
  9. Roy, S., Grigory, S., Smith, M., Kanninen, M.F., and Anderson, M., 'Numerical Simuladons of Full-Scale Conoded Pipe Tests with Combined Loading,' J. fres. Ves. Tech., Vo1.119, pp. 457-466, 1997 https://doi.org/10.1115/1.2842330
  10. Ahamined, M., 'Prediction of Remaining Strength of Corroded Pressurised pipelines.' Int. J. Pres. Ves. & Piping., Vo1.71, pp.213-217, 1997 https://doi.org/10.1016/S0308-0161(96)00081-6
  11. 이억섭, 김호중, '외부부식 형상이 파이프라인의 파손예측에 미치는 영향,' 대한기계학회논문집 A권, Vol. 23, No. 11, pp. 2096-2101, 1999
  12. 김진원, 박치용, '배관실험을 통한 국부감육 배관의 손상거동 평가,' 대한기계학회논문집 A권, Vol. 26, No. 과, pp. 731-738, 2002
  13. American Society of Mechanical Engineer, ASME B&PV Code Sec.m, 'Nuclear Components.,' 1995 ed
  14. American Society of Mechanical Engineer, ANSI/ASME B31.1, 'Power Piping,' 1995