• Title/Summary/Keyword: 내구성능

Search Result 1,224, Processing Time 0.025 seconds

Effects of Water-Repellent on the Physical Properties of Water Paint (발수제가 수성페인트의 물리적 성능에 미치는 영향)

  • Lee, Soo-Yong;Nam, Gee-Yung;Kim, Ji-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.3
    • /
    • pp.259-265
    • /
    • 2014
  • This study is to analyze durability of water-repellent paints mixed with water-repellents as outer surface finishing materials, and evaluate its feasibility. General functions and water-repelling effects were tested, and the feasibility was evaluated based on the test results. The experimental results of heat conduction durability, air permeability, absorption, and bond strength suggested that water-repellent paints mixed with water-repellents were suitable for finishing materials. Considering overall general durability performances, stable mixing ratios were 2, 5, and 8%.

크라이오펌프 국산 개발품 공정 신뢰성 및 내구성 시험

  • In, Sang-Ryeol;Gang, Sang-Baek;No, Yeong-Ho;Yu, Jae-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.119-119
    • /
    • 2013
  • 5년 동안 진행된 고진공 펌프 개발 사업의 일환으로 맥동관형 냉동기에 활성탄 어레이를 장착한 흡기구 직경 14인치 국산 크라이오펌프 완제품이 만들어졌다. 이미 지난해에 완성한 시제품을 가지고 모든 배기성능시험을 완료하고 목표를 뛰어 넘는 성능을 가지고 있음을 입증하였지만 완제품의 경우는 현장에서 스퍼터링 공정에 대한 신뢰성과 열적 내구성 시험이 중요한 항목으로 대두되었다. 개발된 펌프를 생산 공정에 직접 투입하는 모험을 하지 않으면서도 신뢰성을 확보하는 방편으로 카이스트 나노종합팹 센터에서 가동중인 스퍼터링 장비에 완제품을 달고 기존 공정과 같은 방식으로 장치를 운영하면서 외제 상용품을 사용했을 때와 진공성능 및 공정수율을 비교하는 시험을 수행하였다. 또 내구성 시험 항목으로 열부하 시험과 열 사이클 시험을 수행하였다. 열부하 시험은 300도까지 온도를 올릴 수 있는 열판을 펌프 흡기구 배플 앞에 설치하여, 냉동기 2차 냉각단 온도가 20 K 이하로 유지될 수 있는 최대 허용 복사열을 측정하는 방식으로 진행되었으며 열 사이클 시험은 크라이오 펌프의 활성화 기능을 활용하여 완전 활성화(full regen., 10K-300K-10K) 과정을 10회 연속 시행하여 펌프의 배기성능과 기계적 이상 유무를 관찰하였다.

  • PDF

플로팅 건축용 콘크리트 구조물의 철근 겹이음 거동

  • Yang, In-Hwan;Sin, Jae-Hyeok;Kim, Gyeong-Cheol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.213-215
    • /
    • 2015
  • 플로팅 건축용 콘크리트 구조물은 부식환경에 노출되어 매립된 철근의 부식에 따른 구조물의 내구성능에 문제가 발생하게 된다. 철근 부식에 의한 내구성이 저하되는 문제의 여러 효과적인 해결방법 중 하나로 철근 코팅 기법이 있으며, 철근의 용융아연도금시 표면에 용융아연층이 형성되어 철근을 보호하는 장점이 있으나 콘크리트와의 부착 성능에 대한 연구는 미비한 실정이다. 따라서, 본 연구에서는 플로팅 건축용 콘크리트 구조물의 철근 겹이음에 따른 거동 특성연구를 수행하였다.

  • PDF

해양환경에서의 콘크리트 보의 성능연구

  • Yang, In-Hwan;Kim, Gyeong-Cheol;Kim, Yeong-Jun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.261-263
    • /
    • 2013
  • 해양환경에서의 아연코팅철근 콘크리트 보의 휨 성능 및 균열 특성 실험을 수행하였다. 또한, 보에서 발생하는 균열 및 파괴양상을 파악하였다. 그 결과, 해양환경에서의 콘크리트 부재의 피복두께를 기존 설계기준보다 작게 적용시켜도 부재에 발생하는 염해에 대한 내구성을 확보할 수 있으며, 아연코팅 철근의 적용은 일반철근 콘크리트 보다 내구성 측면에서 유리하다고 판단된다.

  • PDF

Evaluation on the Durability of Ductile Fiber Reinforced Cementitious Composites(DFRCC) (고인성 섬유보강 시멘트 복합체의 내구성 평가)

  • Ryu, Gum-Sung;Koh, Kyung-Taek;Park, Jung-Jun;Kang, Su-Tae;Kang, Hyun-Jin;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.535-536
    • /
    • 2009
  • This study was carry out to evaluate the durability of Ductile Fiber Reinforced Cementitious Composites(DFRCC) according to W/B ratio(30, 40, 50%). The results is showing that DFRCC outstandingly improved to compare to plain concrete for the resistance of chloride ion penetration and rapid freezing and thawing

  • PDF

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Durability Evaluation of Tunnel Lining Concrete Reinforced with Nylon Fiber (나일론섬유보강 터널 라이닝 콘크리트의 내구성능 평가)

  • Jeon, Joong-Kyu;You, Jin-O;Moon, Jae-Heum
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.487-493
    • /
    • 2008
  • Tunnel structures are widely used for transportations in mountains areas. To shorten the construction period and to cut down the construction expenditure, a construction technique that a tunnel excavation process and a tunnel lining process are simultaneously performed is often applied in the field. However, due to the vibration and impact caused by excavation process, cracking and deterioration of tunnel lining concrete could happen. This research experimentally investigated the effective role of the usages of blended cement and recently developed nylon fibers for tunnel lining concrete. It has been observed that both nylon fibers and blended cement improve the durability and physical properties of concrete.

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.57-64
    • /
    • 2010
  • A performance test of inter propellant seal for a 75 ton class turbopump is conducted using water to evaluate leakage and endurance performance. Each part of fuel pump side and oxidizer pump side for a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with one-stage seal of carbon floating ring shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the oxidizer pump side part with two-stage seal assembly of carbon floating rings shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A leakage performance test of the inter propellant seal for cryogenic environment will be performed using LN2 in the near future.

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.47-53
    • /
    • 2010
  • A performance test of a 75 ton class turbopump inter propellant seal is conducted using water to evaluate leakage and endurance performance. Each fuel pump side part and oxidizer pump side part of a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with 1 stage carbon floating ring seal shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the LOx pump side part with 2 stage carbon floating ring seal shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A cryogenic leakage performance test of the inter propellant seal will be performed using LN2 in the near future.

  • PDF