• Title/Summary/Keyword: 내구년한

Search Result 287, Processing Time 0.026 seconds

A study on the regulation of durability standard of underground structures monitoring sensors (지하구조물 계측센서의 내구연한 기준에 대한 규정 분석 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.73-81
    • /
    • 2018
  • The purpose of this study is to research the regulation of durability standard of underground structures monitoring sensors. The durability criteria for construction monitoring sensors of domestic construction companies, the standard years of contents such as buildings on the income tax implementation regulations, and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. The durability criterion on products such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the underground structure, is 8 to 10 years. It is considered that the monitoring sensor installed in the paperboard and the concrete structure at the time of construction will have considerably shortened service life rather than the useful life of the product itself due to various adverse factors such as groundwater influence and compaction.

A Case Study on CO2 Uptake of Concrete owing to Carbonation (콘크리트 탄산화에 의한 CO2 포집량 평가의 사례연구)

  • Yang, Keun-Hyeok;Kim, Sang-Chel
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.42-48
    • /
    • 2013
  • The present study assessed the amount of $CO_2$ uptake owing to concrete carbonation through a case study for an apartment building with a principal wall system and an office building with Rahmen system under different exposed environments during use phase and recycling application. The $CO_2$ uptake assessment owing to concrete carbonation followed the procedure established by Yang et al. As input data necessary for the case study, actual surveys conducted in 2012 in Korea, which included data about the climate environments, $CO_2$ concentration, lifecycle inventory database, life expectancy of structures, and recycling activity scenario, were used. From the comparisons with the $CO_2$ emissions from concrete production, the $CO_2$ uptake during the lifetime of structures was estimated to be 5.5~5.7% and that during recycling activity after demolition was 10~12%; as a result, the amount of $CO_2$ uptake owing to concrete carbonation can be estimated to be 15.5~17% of the $CO_2$ emissions from concrete production, which roughly corresponds to 18-21% of the $CO_2$emissions from cement production as well.

Identification of Thermal Flow Boundary Conditions for Three-way Catalytic Converter Using Optimization Techniques (최적화 기법을 이용한 삼원촉매변환기의 열유동 경계조건의 동정)

  • Baek, Seok-Heum;Choi, Hyun-Jin;Kim, Kwang-Hong;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3125-3134
    • /
    • 2010
  • Three-way catalyst durability in the Korea requires 5 years/80,000km in 1988 but require 10 years/120,000km after 2002. Domestic three-way catalyst satisfies exhaust gas conversion efficiency or pressure drop etc. but don't satisfy thermal durability. Three-way catalyst maintains high temperature in interior domain but maintain low temperature on outside surface. This study evaluated thermal durability of three-way catalyst by thermal flow and structure analysis and the procedure is as followings. Thermal flow parameters ranges were determined by vehicle test and basic thermal flow analysis. Response surface for rear catalyst temperature was constructed using the design of experiment (DOE) for thermal flow parameters. Thermal flow parameters for rear catalyst temperature in vehicles examination were predicted by desirability function. Temperature distribution of three-way catalyst was estimated by thermal flow analysis for predicted thermal flow parameters.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 1. Robustness Assessment of Structural Alternatives for the Problem of Urban Floods (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 1. 도시 홍수 문제 구조적 대안의 내구성 평가)

  • Lee, Changmin;Jung, Jihyeun;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.117-125
    • /
    • 2016
  • Current cities encounter various types of water problems due to rapid urbanization and climate change. The increasing significance of urban water problems calls for the establishment of resilient alternatives to prevent and minimize social loss that results from these phenomena. As a background research for establishing resilient infrastructures for the mitigation of urban water problems, we evaluated the robustness of structural alternatives for urban flood as a representative case. Combining the robustness index (RI) and the cost index (CI), we suggested the robustness-cost index (RCI) as an indicator of the robustness of structural alternatives, and applied the index to assess the existing infrastructures and structural alternatives (i.e., sewer network expansion, additional storage tank construction, and green roof construction) at a site prone to floods located around Gangnam-station, Seoul, Korea. At a rainfall intensity frequency range of 2 to 20 years, the usage of a storage tank and a green roof showed relatively high RCI value, with a variation of an alternative showing greater RCI between the two depending on the size of design rainfall. For a rainfall intensity frequency of 30 years, installing a storage tank with some green roofing was the most resilient alternative based on the RCI value. We proposed strategies for establishing resilient infrastructures for the mitigation of urban floods by evaluating the robustness of existing infrastructures and selecting optimal structural alternatives with the consideration of scales of design disaster.

Service Life Evaluation through Probabilistic Method Considering Time-Dependent Chloride Behavior (염해 시간의존성을 고려한 확률론적 내구수명 평가)

  • Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • The service life in RC (Reinforced Concrete) is very important and it is usually obtained through deterministic method based on Fick's 2nd law and probabilistic method. This paper presents an evaluation of $P_{df}$(durability failure probability) and the related service life considering time-dependent behaviors in chloride diffusion and surface chloride content. For the work, field investigation is performed for RC structures exposed to chloride attack for 3.5~4.5years, focusing tidal zone (6.0 m) and sea shore (9.0 m), respectively. Random variables like cover depth, chloride diffusion coefficient, and surface chloride content are obtained, and $P_{df}$ and the service life are evaluated. Unlike the results from deterministic method using LIFE 365, probabilistic method with time effects on diffusion and surface chloride shows a relatively rapid change in the result, which is a significant reductions of service life in the case with low surface chloride content. For probabilistic evaluation of durability, high surface chloride content over $10.0kg/m^3$ is required and reasonable service life can be derived with consideration of time-dependent diffusion coefficient.

Analysis of Reinforced Concrete Structures under Carbonation U sing Monte Carlo Simulation method (MSC 방법을 이용한 철근콘크리트 구조물의 탄산화 해석)

  • Kim, Jee-Sang;Park, Hye-Jong;Kim, Joo-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.301-302
    • /
    • 2009
  • Uncertainties in carbonation process of concrete structures are treated by probability-based durability analysis for carbonation using Monte Carlo simulation technique. The results requires the minimum cover thickness of 53mm for 10% of corrosion probability under 4mm/$year^{0.5}$ of carbonation coefficient. The more researches on statistical properties of design variables may give reliable durability analysis/design methods for carbonation of concrete structures.

  • PDF

Mathematical Models for Predicting Service Lives of Concrete Structures on Chloride Induced Corrosion of Steel Reinfrocement (염소이온에 의한 철근부식에 관한 콘크리트 구조물의 내구년한 예측을 위한 수학적 모델)

  • 오병환;정원기;강승희;장승엽
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.201-206
    • /
    • 1996
  • Recently, to utilize conutry effectively, many concrete structures such as Young Jong Do New Airport. SeoHae Bridege are being constructed. Therefore, Corrosion of steel reinforcement of concrete structures become more and more serious, and prediction of service lives of concrete structures considering steel corrosion is needed much more. The methodologies of predicting service life have been studied for various views, but mathematical modelling based on diffusion theory is generally applied. The purpose of this paper is to investigate current mathematical models, and suggest theoretical basis on estimation of service lives of concrete structures in marine environment. Thus, the procedures for selecting variables such as threshold chloride concentration, diffusion coefficient, etc are suggested, and the service lives calculated through these procedures for various diffusion coefficients and cover depths are presented.

  • PDF

크라이오펌프 국산 개발품 공정 신뢰성 및 내구성 시험

  • In, Sang-Ryeol;Gang, Sang-Baek;No, Yeong-Ho;Yu, Jae-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.119-119
    • /
    • 2013
  • 5년 동안 진행된 고진공 펌프 개발 사업의 일환으로 맥동관형 냉동기에 활성탄 어레이를 장착한 흡기구 직경 14인치 국산 크라이오펌프 완제품이 만들어졌다. 이미 지난해에 완성한 시제품을 가지고 모든 배기성능시험을 완료하고 목표를 뛰어 넘는 성능을 가지고 있음을 입증하였지만 완제품의 경우는 현장에서 스퍼터링 공정에 대한 신뢰성과 열적 내구성 시험이 중요한 항목으로 대두되었다. 개발된 펌프를 생산 공정에 직접 투입하는 모험을 하지 않으면서도 신뢰성을 확보하는 방편으로 카이스트 나노종합팹 센터에서 가동중인 스퍼터링 장비에 완제품을 달고 기존 공정과 같은 방식으로 장치를 운영하면서 외제 상용품을 사용했을 때와 진공성능 및 공정수율을 비교하는 시험을 수행하였다. 또 내구성 시험 항목으로 열부하 시험과 열 사이클 시험을 수행하였다. 열부하 시험은 300도까지 온도를 올릴 수 있는 열판을 펌프 흡기구 배플 앞에 설치하여, 냉동기 2차 냉각단 온도가 20 K 이하로 유지될 수 있는 최대 허용 복사열을 측정하는 방식으로 진행되었으며 열 사이클 시험은 크라이오 펌프의 활성화 기능을 활용하여 완전 활성화(full regen., 10K-300K-10K) 과정을 10회 연속 시행하여 펌프의 배기성능과 기계적 이상 유무를 관찰하였다.

  • PDF

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.