• Title/Summary/Keyword: 낮은핀관

Search Result 20, Processing Time 0.03 seconds

Enhancement of thin film evaporation on low-fin tubes (낮은핀관의 액막 증발 촉진에 관한 연구)

  • 김내현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.674-682
    • /
    • 1998
  • In this study, thin film evaporation of water on low-fin tubes were experimentally investigated. Five low-fin tubes with different fin spacing and fin height were tested. Test range covered 0.146kg/ms $\leq$$\Gamma$$\leq$0.219kg/ms and 10㎾/$\m^2$$\leq$q $\leq$70㎾/$\m^2$. Saturation temperature was loot. Compared with the plain tube, low fin tubes enhanced the water film evaporation from 60% to 100%. Tubes with fin spacing smaller than 2mm and fin height higher than 1mm performed better than tubes with other fin configuration. However, when fin spacing was too small at high film flow or fin height was too high at low film flow, the performance decreased. The heat transfer coefficient slightly increased as the flow rate increased. Correlations are developed based on present data.

  • PDF

Experimental Studies on the Heat Transfer Performance of Plain and Low Finned Thermosyphons (평관 및 낮은 핀관으로 제작한 열사이폰의 열전달 성능에 관한 실험적 연구)

  • Ye, S.S.;Han, K.I.;Park, S.H.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 2001
  • 관 외벽에 낮은 핀을 가진 수직 및 경사 열사이폰의 열전달 성능에 관한 실험적인 연구를 하였다. 관 외벽에 낮은 핀을 가진 이상밀폐 열사이폰의 열전달 성능을 비교 분석하기 위하여 동일한 규격의 평관에서도 실험적인 연구를 하였다. 작동유체는 증류수와 CFC-30을 사용하였다. 열사이폰의 경사각과 자동온도를 변화시키면서 실험한 결과 경사각의 변화에 따라 열사이폰의 열전달 성능은 큰 변화를 나타내었다. 그리고 평관으로 제작한 열사이폰보다 관 외벽에 낮은 핀관을 가진 동관으로 제작한 열사이폰의 열전달 성능이 높게 나타났다. 그리고 열사이폰의 경사각이 $20{\sim}50^{\circ}$ 범위에서 열전달 성능이 높게 나타났다.

  • PDF

An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution (낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.591-598
    • /
    • 2015
  • Pool boiling heat transfer coefficients of a LiBr solution were obtained for seven low fin tubes having different fin pitch and fin height. The test range covered saturation pressure from 7.38kPa to 101.3kPa, heat flux from $20kW/m^2$ to $40 kW/m^2$ and LiBr concentration from 0% to 50%. The optimum fin geometry for the present experimental range turned out to be 26 fpi with 0.18 mm fin height.The advantage of added heat transfer area and the disadvantage of slower bubble growth and departure appear to have yielded an optimum fin pitch. The heat transfer coefficient decreased as saturation pressure decreased and Libr concentration increased. The reason may be attributed to the low saturation pressure, which increased the bubble departure diameter and decreased the bubble departure frequency. As the LiBr concenreation increased, the saturation temperature increased and the mass diffusion rate decreased, which resulted in a reduced heat transfer coefficient. The heat transfer coefficients of the low fin tube were greater than those of the smooth tube. Correlations were developed based on the present data.

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • 이종선
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.68-78
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF

A Study on the Performance of the Condensation and the Boiling Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil (절삭유 냉각용 낮은 핀관의 응축 및 비등 열전달 성능에 관한 연구)

  • Jo, Dong Hyeon;Lee, Jong Seon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.65-65
    • /
    • 1999
  • Heat transfer performance is studied for boiling and condensation of R-11 on integral-fin tubes. Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64 mm height respectively are tested. in case of condensation CFC-11 condensates at saturation stat of 32℃ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1 bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube,. The tube having fin transfer coefficient concerns fin tubes with caves show higher valve than low fin tube having find density of 1299fpm and 30grooves. The overall heat transfer coefficient of fin tube with caves is about 5155 W/mK at 2.8m/s of water velocity, The value is abuot 2.7 times higher than plain tube and 1.3 times higher than low fin tube having fin density of 1299fpm and 30 grooves.

A Study on the Performance of Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil of the Machine Tool (공작기계 절삭유 냉각용 낮은 핀관의 열전달 성능에 관한 연구)

  • 조동현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.125-133
    • /
    • 1998
  • Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64mm height respectively are tested. A plain tube having same diameter as the finned tubes is also tested for comparison. In case of condensation CFC-11 condensates at saturation state of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube. The tube having fin density of 1299fpm and 30grooves has the best condensation overall heat transfer coefficient. However, as far as boiling heat transfer coefficient concerns, fin tubes with cave show higher value than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF

A Study on Field Testing Methods of Compressive Strength for Shotcrete Quality Control (숏크리트 품질관리를 위한 현장 압축강도시험법에 관한 연구)

  • Chang Seok-Bue;Hong Eui-Joon;Moon Sang-Jo
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.175-186
    • /
    • 2005
  • 터널공사에서 숏크리트는 가장 중요한 지보재 이므로 시공중 품질관리를 위한 압축강도시험은 매우 중요하다. 현장 타설 숏크리트의 압축강도는 실험실조건에 비하여 낮은 값을 갖고 있어 현장강도 시험은 필수적이나, 적절한 시험방법의 부재로 인하여 코어채취에 의한 압축강도시험이 적용되고 있다. 이 방법은 적절한 샘플채취와 초기강도 측정에 큰 문제점을 가지고 있다. 따라서, 본 논문에서는 공기압식 핀관입시험법을 고찰하였으며, 압축강도시험의 단점을 해소할 수 있는 점하중강도시험법의 적용성을 검토하였다. 또한, 향후 연구계획으로써, 현장강도시험기법으로 선정된 공기압식 핀관입시험기의 적정성 평가와 숏크리트 압축강도시험을 대체할 수 있는 점하중강도시험의 적용성 분석계획을 제시하였다.

  • PDF

A Study on Enhanced Tubes for Electric Utility Steam Condensers (발전소 수증기 응축기용 전열 촉진관에 대한 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.31-41
    • /
    • 2016
  • A computer program that simulates electric utility steam condensers was developed, and used to investigate the effects of enhanced tubes in steam condensers. The replacement of smooth tubes with enhanced tubes reduces the steam condensing temperature, and increases the efficiency of the electric utility. Therefore, a significant amount of power may be reserved without any modification of the utility. Three enhanced tubes, corrugated, low fin with internal ribs, and low fin with internal 3-D roughness, were considered. The results showed that there is an optimal internal roughness height. Low fin tubes with a 3-D roughness were superior to the other enhanced geometries. This was attributed to longitudinal vortices generated between the circumferential dimples. An additional 0.5 MW~1.3 MW was possible when smooth tubes were replaced with enhanced tubes in the 600 MW electric utility condenser. The additional power increased with increasing coolant temperature. More investigations on fouling, corrosion, and mechanical properties will be necessary for actual applications of enhanced tubes in electric utility condensers.

An Experimental Study on Condensation Heat Transfer of Low-Finned Tubes (낮은 핀관 (low-fin tube)의 응축 열전달 성능에 관한 실험적 연구)

  • Kim, N.H.;Jung, I.K.;Kim, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.298-309
    • /
    • 1995
  • Low-fin tubes are widely used to enhance condensation heat transfer. In this study, condensation heat transfer experiment was conducted on the low-fin tube using R-11. Three different fin densities-787 fpm (fins per meter), 1102 fpm. 1378 fpm-were tested. The results show that low-fin tube enhances the condensation heat transfer considerablely. The enhancement increases as the fin density increases. It was also found that the fin shape and height have a significant effect on the condensation heat transfer coefficient. Slender or high fins showed a higher condensing heat transfer coefficient compared with fat, low fins. For the tube with 1378 fpm, however, excessive fin height decreased the condensing heat transfer coefficient. The reason may be attributed to the increasing condensate retention angle as the fin density increases. The experimental data are compared with existing prediction models. Results show that Webb's surface tension model predicted the data best (within ${\pm}20%$), which confirms that surface tension plays the major role in low-fin tube condensation.

  • PDF

Evaporation Heat Transfer and Pressure Drop of R-404A at Low Flow Rates in 9.5 mm O.D. Smooth and Microfin Tubes (낮은 유량에서 외경 9.5 mm 평활관과 마이크로핀관 내 R-404A 증발 열전달 및 압력 손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.27-36
    • /
    • 2018
  • A significant amount of studies were performed on evaporation heat transfer and pressure drop in microfin tubes. Most studies, however, focused on the refrigerants used in air-conditioners or heat pumps, and very limited information is available on R-404A, which is used in low temperature refrigeration. In this study, the evaporation heat transfer and pressure drop characteristics of R-404A in a 9.5 mm O.D. microfin tube were investigated for the mass flux range from $80kg/m^2s$ and $200kg/m^2s$. A smooth tube of the same outer dimeter was also tested for comparison. The results showed that the heat transfer enhancement ratio of the microfin tube increased with increasing mass flux and the heat flux decreased. The relative contribution of the convective heat transfer and the heat flux on total heat transfer was attributed to the observed trend. The pressure drops of the microfin tube were slightly (maximum 28%) larger than those of the smooth tube. Existing correlations do not adequately predict the measured heat transfer coefficients of pressure drops, probably due to the test range of the present study, which is outside of the existing correlations.