• Title/Summary/Keyword: 납차폐복

Search Result 13, Processing Time 0.027 seconds

Dose Customized Apron Micro Functional Design Using Convergence Shielding Sheet (융합 차폐시트를 이용한 선량 맞춤형 에이프런 마이크로 기능성 디자인)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.119-126
    • /
    • 2021
  • Radiation shielding clothing for medical institutions is used based on lead equivalent of 0.25 mmPb. However, this study intends to study the shielding suit that can guarantee the user's activity while considering the sensitivity of each part of the body. By manufacturing based on eco-friendly shielding material, it was attempted to solve the weight problem and environmental problem of existing lead aprons, and to present the same shielding performance as lead equivalent in thickness. The fabric of the produced shielding sheet was manufactured through a calendar process that adjusts the thickness of the shielding sheet from lead equivalent 0.12 mmPb to 0.32 mmPb. In addition, the usability evaluation of the manufactured shielding clothes was conducted for the subjects who were workers in medical institutions. As a result, the activity became easier and the weight was reduced by 0.26 kg. In the future, it is thought that it is necessary to improve the shielding suit design considering the activity.

Analysis of a Lead Vest Dose Reduction Effect for the Radiation Field at Major Working Places during Refueling Outage of Korean PWR Nuclear Power Plants (국내 가압경수로형 원전 계획예방정비기간 주요 방사선작업에 대한 납 차폐복 선량저감효과 분석)

  • Kim, Jeong-In;Lee, Byoung-Il;Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.237-241
    • /
    • 2013
  • The gamma energy distributions at the major working places during refueling outage of Korean PWR nuclear power plants were measured. In order to estimate the dose reduction effect of a lead vest, Monte Carlo calculation method was used. For the simulations, the MIRD-V phantom with a lead vest was formed and exposed to the measured radiation field. The average measured gamma energy is lower than that of standard which is generally applied to radiation protection procedures. For the efficient use of a lead vest and achievement of radiation protection purpose, it is necessary to estimate the energy distribution of radiation field at working places.

Improvement of shieldability and lightweight of radiation protective apron (방사선 방호용 에이프런의 경량화와 차페능 개선)

  • Kim, Chang-Bok;Kim, Young-Keun;Ku, Hal-Bon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.105-110
    • /
    • 2004
  • 방사선 투시조영 촬영 시 사용되는 방호복의 차폐효율 증가와 경량화는 오랜 시간 연구 대상이 되었다. 이러한 방호복의 질적 향상을 위하여 연구한 결과는 다음과 같다. Apron의 규격인 납 당량 0.25mm에 해당하는 투과선량은 5.2%로 나타났으며, 시료 Sn, Ni, Ti, Cu의 방사선 차폐 효율은 Sn이 가장 높게 나타났다. 증착시료 Sn+Pb 방법에서는 Sn 0.18mm와 Pb 0.1mm, Pb+Sn 방법에서는 Pb 0.1mm와 Sn 0.36mm에서 Apron의 규격인 납 0.25mm 두께로 나타났다. 증착시료 Sn+Pb는 Apron의 규격인 0.25mm 납 당량보다 차폐효율이 높고, 면적당 무게가 가벼워 방호복 물질로 적합한 것으로 사료된다.

  • PDF

Development of Radiation Shielding Sheet with Environmentally-Friendly Materials; II: Evaluation of Barum, Tourmaline, Silicon Polymers in the Radiation Shielding Sheet (친환경 소재의 의료 방사선 차폐 시트 개발; II: 바륨, 토르말린의 실리콘 폴리머 차폐 시트의 성능 평가)

  • Kim, Seon-Chil;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • We developed an alternative radiation shielding material which is economical and has high protection efficiency. We validated the material in the form of sheet to make an apron. We increased the rate of barium and mixed tourmaline into silicon to improve the flexibility and protection rate of the sheet. The results showed that the shielding effect at low radiation energy is good enough with both 5 mm and 7 mm thickness. In the future, we will perform a quantitative evaluation of the reproducibility, volumetric efficiency, and porosity in mixing the ingredients.

Improvement of the shieldability and lightweight of a radiation protective apron (방사선 방호용 에이프런의 경량화와 차폐능 개선)

  • Kim, Young-Keun;Jang, Young-Ill;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.45-50
    • /
    • 2003
  • In this work, we characterized the shieldability and lightweight of radiation protective aprons which were consisted of various metal(Pb, Sn, Ni, Ti and Cu) by measuring the x-ray dose transmitted through the filters. The transmitted ratio and lead equivalent of various metal were obtained by linear interpolation and the lead equivalent of double layered filters contained Pb layer was determined. The transmitted ratio of the apron(0.25 mmPb) specified in KS B 0845 was 5.2%. The transmitted ratio of the filters at the thickness of 0.6 mm was decreased in the other of Ni(32.60%), Ti(17.75%), Cu(13.25%) and Sn(3.84%). From the results of experimental evaluation for combined filter of Pb and Sn, it was founded that in the case of the first Sn layer, the lead equivalent was higher than that of the first Pb layer. The lead equivalent corresponding to apron of 0.25 mmPb was obtained in the double layered filters of Sn(0.19 mm) - Pb(0.1 mm) and Pb(0.1 mm) - Sn(0.37 mm). Thus, the Sn-Pb filter had the lower weight about 13% than apron of 0.25 mmPb.

  • PDF

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

A Study on the Non-Toxic Compound-based Multi-layered Radiation Shielding Sheet and Improvement of Properties (무독성 화합물 기반의 다층 구조 방사선 차폐 시트 개발과 특성 개선에 관한 연구)

  • Heo, Ye Ji;Yang, Seung u;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.149-155
    • /
    • 2020
  • Most of radiation protection clothing is made of lead with excellent radiation shielding because it has excellent process ability and economic efficiency and has a high atomic number. However, lead is classified as a hazardous heavy metal, and there is a risk of lead poisoning. Recently, research to replace lead has been actively conducted. In this study, a research on a shielding sheet with improved physical properties while maintaining the radiation shielding ability equivalent to that of conventional materials by mixing two materials that are harmless to the human body, such as BaSO4 and Bi2O3, and a silicone material binder Was performed. For comparison evaluation with the existing lead shielding sheet, the shielding rate was evaluated using a 40 degree shielding sheet having the highest porosity. As a result, it was analyzed that the shielding rate was superior to 9 % or more at the same thickness. In addition, as a result of studies to improve the physical properties of the shielding sheet, it was analyzed that the shielding sheet mixed with BaSO4/nylon/Bi2O3 was the best.