• Title/Summary/Keyword: 나사

Search Result 833, Processing Time 0.021 seconds

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

Latarjet Operation for Anterior Shoulder Instability with Glenoid Bone Defect (관절와 골 결손을 동반한 견관절 전방 불안정증에 대한 Latarjet 술식)

  • Cho, Seung-Hyun;Cho, Nam-Su;Yi, Jin-Woong;Choi, Il-Hun;Kwack, Yoon-Ho;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • Purpose: We wanted to evaluate the clinical results of the Latarjet procedure for treating anterior shoulder instability combined with a glenoid bone defect. Materials and Methods: Between Oct. 2006 and May. 2007, fourteen patients underwent a Latarjet operation to treat their anterior shoulder instability combined with a glenoid bone defect. The mean follow-up period was 15 months (range: 12 to 19 months), and the average age at the time of surgery was 29.9-years-old (range: 19 to 44 years). There were 13 males and 1 female. Eight patients exhibited involvement of the right shoulder. The dominant arm was involved in 8 patients. Six patients had undergone a previous arthroscopic Bankart repair before their Latarjet operation and 2 patients had a history of seizure. Results: The average Rowe score improved from 51.8 to 80.2 with 9 excellent, 4 good, and 1 fair results. The average Korean shoulder score for instability improved from 61.6 to 82.1 postoperatively. The active forward flexion and external rotation at the side of the involved shoulder was an average of $8^{\circ}$ and $16^{\circ}$ less than that of the uninvolved shoulder. The muscle strength of the involved shoulder measured 78.7% in forward flexion and 82.5% in external rotation, as compared with that of the uninvolved shoulder. There was 1 case of dislocation, 1 transient subluxation, 2 fibrotic unions, 1 resorption of the transferred coracoid process, 1 intraoperative broken bone, 1 transient musculocutaneous nerve injury and 1 case of stiffness. Conclusion: The Latarjet procedure for treating anterior shoulder instability combined with a significant glenoid defect effectively restores function and stability through extending the articular arc at the expense of external rotation. We should be cautious to avoid or detect complications when performing coracoid transfer.

Complications of PCL Reconstruction using Tibial Inlay Technique (경골 Inlay 방법을 이용한 후방 십자 인대 재건술의 합병증)

  • Kim Myung-Ho;Park Hee-Gon;Yoo Moon-Jib;Byun Woo-Sup;Shim Shang-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.2
    • /
    • pp.128-133
    • /
    • 2004
  • Purpose: This study was planned to evaluate complications? of posterior cruciate ligament (PCL) reconstruction with tibial inlay technique using autogenous bone-patellar tendon-bone graft. Materials and Methods: From September 1994 to January 2004, we analyzed surgical complications in fifty-seven patients with fifty-eight cases who underwent PCL reconstruction. Fifty of them were male and seven female. The mean age of the patients was 35(15$\~$73). Twenty eight cases of injury were isolated PCL, while thirty cases had associated injury of knee. The causes of injury were thirty-nine cases of traffic accident, seven sport injuries, seven fall down injuries, and five of others. The follow-up study was done at 4 weeks, 3 months,6 months and 1 year after surgery. KT-2000 arthrometer and posterior stress X-ray were used to examine the stability of the knee joint and the Lysholm Knee Score and a variety of clinical complications were evaluated. Results: Although the mean score of the preoperative Lysholm Knee Score was 43.2, the postoperative score was increased to 87.9. The preoperative mean value of knee stability using KT-2000 arthrometer was 8.75 mm(6.2$\~$14.3 mm) but the postoperative mean was 3.41 mm(2.1$\~$10.6 mm). The intraoperative complications were: one case of popliteal artery injury with compartment syndrome, one case of patellar fracture, two cases of 20$^{\circ}$ flexion loss, and two cases of anterior cortical penetration of the screw through proximal tibia during screw fixation. The postoperative complications were: eleven cases of knee instability, one case of patellar fracture, five cases of extension loss, thirteen cases of flexion loss, twenty-one cases of around knee pain and eight cases of kneeling pain. Conclusion: After PCL reconstruction with tibial inlay technique using autogenous bone-patella tendon-bone graft, complications were observed in this study. Careful attention during and after the operation, as well as rehabilitation must be required.

  • PDF

Accelerated Rehabilitation After Arthroscopic Bankart Repair - A Prospective Randomized Clinical Study - (관절경적 Bankart 봉합술후 적극적 재활치료 - 전향적 임상연구 -)

  • Kim Seung-Ho;Ha Kwon-Ick;Jung Min-Wook;Lim Moon-Sup;Kim Young-Min;Park Jong-Hyuk;Cho Yang-Bum
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.79-88
    • /
    • 2002
  • Purpose: In this prospective, randomized study, we compared the results of early motion versus conventional immobilization after the arthroscopic Bankart repair. Materilal and Methods : We performed an arthroscopic Bankart repair using suture anchors in 62 patients with traumatic anterior shoulder instability and randomized them into two groups; Group 1 (n=28; mean age, 28 years) underwent three-week of immobilization and conventional rehabilitation program, while Group 2 (n=34; mean age, 29 years) underwent an accelerated rehabilitation program with staged range of motion and strengthening exercises starting from the immediate postoperative day. Selected patients were non-athletes with a classic Bankart lesion and a robust labrum. Analysis of outcome included pain scores (6-week and follow-up: 31(9 months), range of motion, return to activity, recurrence, patients’ satisfaction with each program, and shoulder scores (ASES, UCLA, and Rowe). Results : The recurrent rate was not different between the two groups (2 anterior apprehension from each group) (p=0.842). Patients with accelerated rehabilitation resumed functional range-of-motion faster and returned earlier to the functional level of activity (p<0.05). Accelerated rehabilitation decreased postoperative pain and more patients were satisfied with this program (p<0.05). No differences were found between the two groups at the follow-up with regards to the shoulder scores, return to activity, pain score, and the range-of-motion. Conclusions : Early mobilization after arthroscopic Bankart repair does not increase the recurrence rate in selected patients. Although the final outcomes are similar in both groups, the accelerated rehabilitation program promotes functional recovery and reduces postoperative pain, which enables patients an early institution of desired activities.

  • PDF

The Effect of Repetitive Insertion and Pullout of Spinal Screws on Pullout Resistance : A Biomechanical Study (척추 수술에 사용되는 나사못의 반복 삽입과 인출이 인장항력에 미치는 영향 : 생체 역학적 연구)

  • Bak, Koang Hum;Ferrara, Lisa;Kim, Kwang Jin;Kim, Jae Min;Kim, Choong Hyun;Benzel, Edward C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.131-136
    • /
    • 2001
  • Object : The clinical uses of screws are increasing with broader applications in spinal disorders. When screws are inserted repeatedly to achieve optimal position, tips of screw pitch may become damaged during insertion even though there are significant differences in the moduli of elasticity between bone and titanium. The effect of repeated screw insertion on pullout resistance was investigated. Methods : Three different titanium screws(cortical lateral mass screw, cancellous lateral mass screw and cervical vertebral body screw) were inserted into the synthetic cancellous material and then extracted axially at a rate of 2.4mm/min using Instron(Model TT-D, Canton, MA). Each set of screws was inserted and pulled out three times. There were six screws in each group. The insertional torque was measured with a torque wrench during insertion. Pullout strength was recorded with a digital oscilloscope. Results : The mean pullout force measurements for the cortical lateral mass screws($185.66N{\pm}42.60$, $167.10N{\pm}27.01$ and $162.52 N{\pm}23.83$ for first, second and third pullout respectively : p=0.03) and the cervical vertebral body screws($386.0N{\pm}24.1$, $360.2N{\pm}17.5$ and $330.9N{\pm}16.7$ : p=0.0024) showed consecutive decrease in pullout resistance after each pullout, whereas the cancellous lateral mass screws did not($194.00N{\pm}36.47$, $219.24N{\pm}26.58$ and 199.49N(36.63 : p=0.24). The SEM after insertion and pullout three times showed a blunting in the tip of the screw pitch and a smearing of the screw surface. Conclusions : Repetitive screw insertion and pullout resulted in the decrease of pullout resistance in certain screws possibly caused by blunting the screw tip. This means screw tips suffer deformations during either repeated insertion or pullout. Thus, the screws that have been inserted should not be used for the final construct.

  • PDF

Comparision of Trans-Tibial and Anteromedial Portal Approach in Femoral Tunneling of Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술의 대퇴골 터널 굴착시 경경골 접근법과 전내측통로 접근법의 비교)

  • Sohn, Sung-Keun;Chang, Yun-Suk;Chung, ll-Kwon;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.75-81
    • /
    • 2004
  • Purpose: Recent development and advances in arthroscopic surgical techniques for Anterior Cruciate Ligament(ACL) reconstruction have led to the ideal location for the etric point from 10 o'clock (in right knee) and 13:30 (in left knee) to 10:30 (in right knee) and 14 o'clock (in left knee) in the frontal plane. This study was performed to compare operative methods and the radiologic results of femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Material and Methods: From January 2003 to May 2004, one-hundred reconstructions of anterior cruciate ligament were performed. Group I (femoral tunnel through tibial tunnel) was composed of 50 cases and group ll (femoral tunnel through anteromedial portal) was consisted of 50 cases. The study was performed to compare the radiographic results of femoral tunnels made through the tibial tunnel and the anteromedial portal and operative methods. Results: In operative methods at Group II, femoral tunnel was made more easily at isometric point than Group I, a good visual field was achived because 100$^{\circ}$ flxion of knee, they can be reduced risk of posterior cortical breakage and tunnel-graft mismatching and decreased divergence of femoral interference screw in radiology (P<0.05). The angle between femoral tunnel and longitudinal axis of ACL wae increased at Group ll. Conclusion: Aanteromedial portal technique was more useful in ACL reconstruction for femoral tunnel toward 10 o'clock to10:30(in right) or 1:30 to 2 o'clock(in left).

  • PDF

Disability-Rights Based International Cooperation: With Some References to North Korea (장애 권리 기반한 국제협력: 북한 관련하여)

  • Kim, Hyung Shik;Woo, Joo Hyung
    • 재활복지
    • /
    • v.22 no.2
    • /
    • pp.1-30
    • /
    • 2018
  • This paper attempts to explore the place of human and disability rights from the perspective of Social Welfare within the context of the UN Disability Rights Convention of 2006. The overall discussion is focused especially upon the situations of human and disability rights in the Democratic People's Republic of Korea (North Korea) as it is being challenged to drastically address the issues of human rights in general, and disability rights in particular. The UN Disability Rights Convention challenges every ratified State party to commence legal reforms, legal harmonization, and policy and program developments to implement the Convention. Both North and South Korea are not exceptions to this. Even without drawing upon the UN's the Commission of Inquiry on Human Rights in the Democratic People's Republic of Korea, the dire situation of human rights in North Korea is well documented. However, this paper does not assume South Korea's human rights are any way superior to that of North Korea. This paper spells out areas for further action common to two Koreas and to any other nations for that matter. Apart from the general discussion on disability rights, the distinctive contribution of this paper lies in the fact that it has endeavored to draw upon any latest information and data on North Korea. It relied on various sources from UN and also from North Korea itself. One can note that North Korean disability authorities are making strenuous efforts to improve human rights of persons with disabilities in their desires to seek assistance from outside. It also shows an enormous need for international cooperation in seeking financial and material supports. This paper notes the latest political development between North and South Korea in taking "phased" steps for peace and stability as a positive sign for North and South Koreans' DPOs collaboration under the banner of International Cooperation of the article 32 of the UN Disability Rights Convention. More critically, this paper points to the further need to improve the overall data bases to ensure balanced legal reforms, policy developments and sharpen the areas of international collaboration.

Clinical and Radiological Outcomes of 'Blocking Kirschner Wire Technique' in Displaced Intra-Articular Calcaneal Fractures via the Extended Sinus Tarsi Approach (전위된 관절 내 종골 골절에서 확장된 족근동 접근법을 통한 Kirschner Wire 강선 지지대 고정술의 임상 및 영상학적 결과)

  • Lee, Jeong-Kil;Kang, Chan;Kim, Sang-Bum;Lee, Gi-Soo;Hwang, Jung-Mo;An, Byung-Kuk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.224-233
    • /
    • 2021
  • Purpose: The purpose of this study was to retrospectively evaluate the effect of 'Blocking Kirschner Wire (K-Wire) Technique', which has been developed to reduce protrusion of the lateral wall, in maintaining the level of reduction through clinical and radiological outcomes. Materials and Methods: Twenty-two patients with displaced intra-articular calcaneal fractures who used the blocking K-wire to maintain reduction (group A) and 44 patients that did not use blocking K-wire and were paired in 1:2 ratio with those Group A patients (group B), between January 2015 and December 2017 were enrolled in the study. All surgical procedures were performed via the extended sinus tarsi approach, and internal fixation using cannulated screws, Steinmann pins and K-wires was performed. American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot scale and postoperative recovery of exercise ability were compared for postoperative clinical outcomes. The radiological results were compared the Böhler angle, Gissane angle, calcaneal height and width, step off of posterior calcaneal joint, and the degree of protrusion of the lateral wall. Moreover, postoperative complications in both groups were compared. Results: There were no significant differences in the clinical outcomes of the two groups (p=0.924, p=0.961). The amount of Böhler angle, Gissane angle, calcaneal height and width, and step off of posterior calcaneal joint from the radiological results was not significantly different between the two groups (p=0.170, p=0.441, p=0.230, p=0.266, and p=0.400). However, the degree of protrusion of the lateral wall was 1.78 mm and 4.95 mm in group A and group B, respectively, and the difference between the two groups was significant (p=0.017). Although sural nerve entrapment and painful exostosis were more frequent in group B, they were occurred in a non-significant manner (p=0.293, p=0.655). Conclusion: Most of the clinical and radiological results as well as the complications were not significantly different between the two groups. However, the degree of protrusion of the calcaneus lateral wall in group A was promising. The 'Blocking K-Wires Technique' established by the authors may be an effective surgical option for maintaining the reduction of the lateral wall protrusion in displaced intraarticular calcaneal fractures.

Study on the Safety of Firefly Luciferase in Human as a Transient Reporter Gene of Oncolytic Virotherapy (항암 바이러스 치료제의 보고유전자로써 반딧불이 루시퍼레이즈의 인체 내 안전성에 대한 연구)

  • Hong, Young Mi;Yoon, Woong Hee;Lee, You Ra;Kim, Soo Ji;Ngabire, Daniel;Narayanasamy, Badrinath;Ornella, Mefotse Saha Cyrelle;Kim, Myunghee;Cho, Euna;Lee, Bora;Hwang, Tae-Ho
    • Journal of Life Science
    • /
    • v.31 no.11
    • /
    • pp.1028-1036
    • /
    • 2021
  • Firefly luciferase (FLuc) can function as an efficient marker in the gene and viral therapies. Nonetheless, its clinical translation has been unaccomplished with the concerns on its exogenous nature and the similarity with human fatty acyl-CoA synthetase. In this study, we aimed to show safety of FLuc by conducting a set of preclinical experiments and a human use. Initially, FLuc permeability across the plasma membrane was investigated by delivering the FLuc-carrying viral vector, OTS-412, or the FLuc recombinant protein. After in vitro infection of OTS-412 into different cancer cell lines, FLuc activity was detected only in the cell lysates, but not in culture media. In addition, recombinant FLuc protein further showed the impermeability against the plasma membrane. Similar result was also observed in the in vivo experiment. After being injected into the VX2 tumor-bearing rabbit, the FLuc exclusively resided within the tumor tissue without being detected in the blood plasma or other organs. Human cancer cell lines originated from various organs were lysed and treated to the FLuc, and none of the human substrates was reactive against the FLuc. As a final step, FLuc recombinant protein was intravenously injected into a human. The luciferase was degraded with the half-life of 20 to 30 minutes in blood, and was untraceable from 1.5 hr after the injection. In addition, the blood plasma was nonresponsive against the fatty acids. Hematological analysis was also comparable between the pre- and post-injection. Altogether, our study collectively demonstrates the safety of the firefly luciferase.

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.