• Title/Summary/Keyword: 나사이음

Search Result 833, Processing Time 0.028 seconds

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Acutrak Screw Fixation for Radial Head Fracture -7 Cases Report- (Acutrak 나사를 이용한 요골두 골절의 치료 -7례 보고-)

  • Kim, Kwang-Yul;Lim, Moon-Sup;Shin, Heung-Sub;Choi, Shin-Kwon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: To evaluate the efficiency of Acutrak screw fixation for radial head fracture (Mason type 2) without considering the safe Bone of radial head. Materials and Methods: Consecutive seven radial head fracture of Mason type II underwent internal fixation with Acutrak screws from May 2001 to February 2003. The mean follow-up period was 1.2years (ranged, $6 months{\sim}2.5 years$). The mean age of patients was 47 years old (ranged, $36{\sim}60years$ old). The cause of injury were fall down -4 cases and traffic accident -3 cases. The results were evaluated by Mayo Clinic results scoring system. Results: Functional Rating Index of Mayo Clinic was excellent- 2 cases and good- 5 cases. There were no nonunion, loosening, heterotopic ossification, infection or degenerative changes. The postoperative range of motion in elbow joint is nearly full for flexion, extension, pronation and supination in this study Conclusion: Consideration of safe zone is not necessary when Acutrak screws are used for radial head fracture. It seems to be a useful method that Acutrak screw fixation for radial head fracture (Mason type II) could achieve good radiologic and clinical results without influencing proximal radio-ulnar joint and has powerful fixation.

  • PDF

Evaluation of Structural Performance and Improvement of Screw Thread Shape on 1,300 MPa High Strength Bolts (1,300 MPa급 고장력볼트의 나사형상 개선 및 성능평가)

  • Han, Jong Wook;Kim, Jin Ho;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.189-198
    • /
    • 2011
  • Although high strength bolts with tensile strength of 1,000 MPa are mainly used in steel structure construction sites throughout the world, new high strength bolts are required owing to the installation of continuous long-span bridges resulting from the development and distribution of high strength steel and ultra-thick steel plates. Currently, high strength bolts with tensile strength of 1,300 MPa are being used. However, as they tend to place a large load on a small section of space, a high strength bolt of high structural performance and screw thread shape with less stress concentration is thought to be more effective. This study conducted analyses in order to develop an improved screw thread shape relative to the KS screw thread shape. A new screw thread shape with less stress concentration and effective load distribution at the time of fastening bolts and nuts was provided upon analysis of the characteristics of screw thread shape. Additionally, in an experimental study, the structural performance of high strength bolts with tensile strength of 1,300 MPa was investigated. The results revealed that the new screw thread shape was more effective than the existing screw thread shape in terms of structural performance and mitigating the stress concentration.

Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report - (관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 -)

  • Kim, Hyung-Sik;Koh, Il-Hyun;Kim, Sung-Guk;Chun, Yong-Min;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.94-98
    • /
    • 2011
  • Purpose: We present a case of anterior glenoid rim comminuted fracture that was treated with arthroscopic reduction and an AO headless compression screw (HCS) fixation. Materials and Methods: A 31-year old man complained of left shoulder pain after falling down on stairs. The anterior glenoid comminuted fragments were arthroscopically reduced. Fixation with an AO HCS was done after placement of 1.1 mm Kirschner wire as a guide pin through a standard cannulated anterosuperior portal. Results: Twelve months after the operation, union of the fracture was achieved and the range of motion was fully recovered. He did not complain of any discomfort during his activities of daily living. Conclusion: An AO HCS had various screw sizes and this was good for fixation of a small glenoid fracture and a long drill bit and screw driver were useful for fixation of deep seated glenoid fracture. A short guide wire could be replaced by a 1.1 mm K-wire. An AO HCS was useful for fixation of an anterior glenoid rim comminuted fracture.

Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis (연결부 형태가 다른 두 가지 scallop 임플란트에서 경부 나사선 피치가 응력 분포에 미치는 영향 : 삼차원적유한요소분석)

  • Choi, Kyung-Soo;Park, Seong-Hun;Lee, Jae-Hoon;Huh, Jung-Bo;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.111-118
    • /
    • 2013
  • Purpose of present study is to investigate the effects of thread pitch in coronal portion in scalloped implant with 2 different connections on loading stress using 3 dimensional finite element analysis. Scalloped implant with 4 different thread pitches (0.4mm, 0.5mm, 0.6, and 0.7mm) in the coronal part was modeled with 2 different implant-abutment connections. Platform matching connection had the same implant and abutment diameter so that they were in flush contact at the periphery while platform mismatching connection had smaller abutment diameter than implant so that their connection was made away from periphery of implant-bone interface. Occlusal loading of 100N force was applied vertically and 30 degree obliquely to all 8 models and the maximum von Mises bone stress was identified. Loading stress as highly concentrated in cortical bone. Platform mismatching scalloped implant with small thread pitch (0.4mm) model had consistently lowest maximum von Mises bone stress in vertical and oblique loads. Platform matching model had lowest maximum von Mises bone stress with 0.6mm thread pitch in vertical load and with 0.4mm thread pitch in oblique load. Platform mismatching connection had important roles in reducing maximum von Mises bone stress. Scalloped implant with smaller coronal thread pitch showed trend of reducing maximum von Mises bone stress under load.

Early loading on a maxillary posterior single implant with deepened threads: a case report (깊은 나사선을 갖는 임플란트를 이용한 상악 구치부 조기 하중: 증례보고)

  • Han, Chang-Hoon;Kim, Hyun-Seung;Park, Sang-Won;Yun, Kwi-Dug;Joo, Han-Sung;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.253-258
    • /
    • 2014
  • This case report shows an early loading at the maxillary posterior area with the wide diameter implant which has a deepened threads after removal of failed implant. Implant Stability Quotient (ISQ) value has represented favorable result for one year. This clinical report describes the potential of early loading on a maxillary posterior single implant with deepened threads.