• Title/Summary/Keyword: 나사이음

Search Result 835, Processing Time 0.024 seconds

Suture Anchor Capsulorraphy in the Traumatic Anterior Shoulder Instability: Open Versus Arthroscopic Technique (봉합나사를 이용한 Bankart 봉합술의 관절경적 및 개방적 수술의 비교)

  • Kim Seung-Ho;Ha Kwon-Ick;Kim Sang-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.157-169
    • /
    • 1999
  • Eighty-nine shoulders in eighty-eight patients with traumatic unilateral anterior shoulder instability were evaluated for Rowe and UCLA scores, recurrence, return to activity, and range of motion by an independent examiner at an average of 39 months after either arthroscopic or open Bankart repair using suture anchors. The arthroscopic technique included a minimum of 3 anchors, and a routine incorporation of capsular plication and proximal shift. Twenty­six shoulders(86.6%) out of thirty in the open Bankart repair group had excellent or good results while fifty­four(91.5%) of the fifty-nine shoulders with arthroscopic Bankart repair had excellent or good results. The arthroscopic group revealed significantly better results in the Rowe(p=.041) and UCLA scores(p=.026). Two shoulders in each group developed redislocation. There were no significant differences in the loss of external rotation and return to prior activity between the two groups(p>.05). The residual instability occurred more frequently in the group of patients with lesser anchors. Arthroscopic suture anchor capsulorraphy has results equal to or better than the open Bankart procedure.

  • PDF

Arthroscopic Reduction of Subluxed Medial Meniscus using Suture Anchor for Restoration of Hoop Stress - Technical Note - (버팀테응력 회복을 위한 아탈구된 내측 반월상 연골의 Suture anchor를 이용한 정복술 - 술기 보고 -)

  • Kim, Jaw-Hwa;Lee, Yoon-Seok;Kim, Chul;Han, Seung-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.280-284
    • /
    • 2009
  • Purpose: The authors introduce a new technique of arthroscopic reduction of subluxed medial meniscus using suture anchor for the restoration of hoop stress. Operative Technique: Anterolateral, anteromedial, and medial midpatellar arthroscopic portal are used. Arthroscope was inserted through anterolateral portal. Through the scope, we confirmed subluxation of medial meniscus. Transection of menisci including radial and root tear were excluded. We released the anterior horn of medial meniscus through anteromedial and burred the future insertion site of suture anchor. After inserting suture anchor through medial midpatellar portal, we used 90 degree suture hook and no.2 Nylon to retrieve the suture of inserted anchor. We tied the suture by sliding knot-tying method. Weight bearing was limited for 6 weeks postoperatively. Conclusion: Arthroscopic retightening of medial meniscus is less invasive, conserving and progressed method for subluxed meniscus.

  • PDF

반복하중에 따른 임플란트 시스템의 풀림에 관한 연구

  • 신하식;전흥재;한종현;이수홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.292-292
    • /
    • 2004
  • 치과용 임플란트(Implant)란 상실된 자연치아를 대신하여 골 내에 매식하는 인공치근을 말한다. 임플란트는 인접 자연치아의 보호, 심미적 안정 등의 장점으로 인해 그 수요가 늘어나고 있으며, 단일치아 임플란트의 경우, 부분 무치악 환자들에게 있어서 우수한 치의학적 해법이 되어왔다. 대부분의 임플란트는 두 개 이상의 구성요소로 이루어져 있으며, 각각의 구성요소는 나사에 의해 결합되어 있다. 많은 연구결과를 통해, 임플란트의 나사 풀림 현상(Screw loosening)은 임플란트와 관련하여 가장 흔한 문제로 나타나고 있다.(중략)

  • PDF

Leakage-reduction Measures at a Joint between CPVC Piping for a Sprinkler System and a Pipe Expansion (스프링클러설비용 CPVC관과 신축배관 접속부분에서의 누수저감 대책에 관한 연구)

  • Lim, Chun-Ki;Lim, Yun-Tack;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.21-30
    • /
    • 2015
  • In this study, we try to suggest measures to reduce leakage at a joint between CPVC piping for a sprinkler system and a pipe expansion through reviews of domestic and foreign standards and related tests. The quality of the waterproof rubber packing material between a valve socket and pipe expansion nut was examined. In the leak test, the valve socket material over the expansion part of the metal pipe nut was found to use a metal part or a schlorinated polyvinyl chloride pipe nut part. In addition, the KS B 0221 standard for parallel pipe threads with threaded and thread inspection criteria and inspection standards in order to ensure an acceptable quality of valve socket, there is a need to amend the regulations to comply with the KS B 5223 (screw thread limit gauges parallel pipe threads). We do not have detailed standards for expansion piping nuts for waterproof rubber ring material, so we need to amend the relevant criteria for EPDM material to be used with excellent waterproofing, for which both NBR and EPDM are currently used.

Study of Production and Material Properties of Micro Screw Using SWCH18A and SUS XM7 Materials (SWCH18A 와 SUS XM7 을 적용한 초소형 나사제작 및 물성분석에 관한 연구)

  • Ra, Seung-Woo;Kim, In-Rak;Hwang, Sung Tack
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.1043-1048
    • /
    • 2014
  • As micro screws feature reduced screw lengths and pitches, the resulting clamping force diminishes because of the reduced length of the actual joints. The elements of the clamping force are material, geometry, and friction. We studied the shrinking size of the screw and the methods to improve the clamping force by changing the material. We developed a micro screw using SWCH18A and SUS XM7 materials, and obtained the precision and thickness of the pitch through three-dimensional measurement. We also measured the external resistance of the micro screw by applying the Vicker's hardness test and conducted a break surface analysis using a break torque test and SEM for obtaining the break characteristics.

Evaluation of Clamping Forces according to Length-to-diameter Ratios and Preserved Thread Lengths of High Strength Bolts (고력볼트의 길이-직경비 및 여유나사길이에 따른 조임력 평가 연구)

  • Kim, Sang Seup;Kim, Sung Yong;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.3 s.46
    • /
    • pp.259-268
    • /
    • 2000
  • In the friction-type joints the external applied load is transmitted by frictional force acting on the contact area of the plates fastened by the high strength bolts. This frictional force is proportional to the product of the bolt clamping force and slip coefficient of the faying surface. But the bolt clamping force is dependent on many factors when the turn-of-nut method is used. The preserved thread length and length-to-diameter ratios are one of the major factors governing the bolt clamping force. This paper presents the correct method of high strength bolt tightening through the experiment on the mechanical properties on sets of high strength bolts in accordance with preserved thread length and length-to-diameter ratios.

  • PDF

A new retaining method of cement-retained restoration with linguo-horizontal insertion of fiber post (시멘트 유지형 임플란트 보철물의 신개념 유지 방식: Fiber post의 설측 수평 삽입에 의한 유지력 보완)

  • Yoon, Na Ree;Lee, Richard sungbok;Lee, Suk Won;Ahn, Su Jin;Park, Su Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • The retaining methods of implant prosthesis were classified into a screw-retained and a cement-retained type. A screw-retained prosthesis has many advantages, such as retrievability, preventing residual cement, while their disadvantages include the possibility of screw loosening and fracture, on the contrary advantages of cement-retained prosthesis are relatively low cost, but they are difficult to retrieve. To combine the advantages of both type, screw-cement retained prosthesis (SCRP) type have been introduced. But they still require ideal implant placement. So we introduce fiber post retained prosthesis without residual cement for preventing soft tissue trouble due to excessive cement.

A Case of New Surgical Correction of Angular Limb Deformities Using One Screw Implant & Periosteal Transection in a Thoroughbred Foal (Thoroughbred 망아지에서 단일나사못 장착 및 골막박리를 이용한 지세교정술)

  • Yang, Jae-Hyuk;Lim, Yoon-Kyu
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.177-180
    • /
    • 2012
  • Angular limb deformities (ALD) are common in foals. A 30-days-old Thoroughbred foal was presented for the evaluation of severe ALD of the both forelimbs. On radiographic examination, both distal radiuses were diagnosed as valgus angular limb deformities. But the degree of deviation of right forelimb was so severe that we tried to correct one after the other. We tried new surgical correction method combination of one screw implant on medial aspect for growth retardation and periosteal transection on lateral aspect of the right forelimb. 40 days later, successfully corrected and then removed the screw. After the right forelimb correction, the periosteal transection on left forelimb was performed. We did the inhalation anesthesia using isoflurane. There were no complications such as fibrosis over the screw heads, and overcorrection that produces an opposing deformity identified. These results suggest that combination of one screw implant and periosteal transection technique is able to be a safe and effective method to correct severe ALD in the foal.