• Title/Summary/Keyword: 나사못 고정술

Search Result 65, Processing Time 0.038 seconds

Patellar fracture after transverse screw fixation in sports athletes - A case report - (운동선수에서 횡방향 나사 고정 후 발생한 슬개골의 골절 - 증례 보고 -)

  • Ra, Ho Jong;Kim, Sung Tae;Ha, Jeong Ku;Kim, Jin Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.109-112
    • /
    • 2011
  • Anatomical reduction and strong fixation in displaced patella fracture are needed for restoration of knee function and strength and early range of motion exercise. According to the type of fracture and various operational methods, their many complications have been reported. We report 2 cases of transverse patella fracture which were caused by transverse screw fixation in longitudinal patella fracture and fracture of bipartite patella in athletes.

  • PDF

Outcomes after Arthroscopic Repair of Anterior Shoulder Instability after Metal Anchor to Biodegradable Anchor Fixation (견관절 전방 불안정성에 대한 관절경 치료 결과: 금속 나사못 및 흡수성 나사못 고정의 결과 비교)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Han, Bo-Ram
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.158-164
    • /
    • 2008
  • Purpose: We compared the results of arthroscopic Bankart repair using metal and biodegradable anchor fixation. Materials & Methods: We reviewed 26 patients with anterior shoulder instability treated by arthroscopic Bankart repair from October, 2006, to March, 2007, 15 patients with metal anchors and 11 patients with biodegradable anchors. The average age was 27.4 years old (range: 17~55) and mean follow-up was 14 months (range: 12~17 months). Functional outcome was evaluated using the Korean Shoulder Score for Instability (KSSI), Rowe's Bankart Grading scale (RBGS), ASES score, and UCLA scores. Results: In the metal-anchor group, the improvements of mean KSSI, ASES, UCLA score, and RBGS were 20.6, 24.0, 4.0, and 45.5, respectively. In the biodegradable anchor group, improvements of mean KSSI, ASES, UCLA score, and RBGS were 21.0, 23.6, 4.6, and 48.9. The improvements in final outcomes were not significantly different (p>.05). One metal problem and one traumatic redislocation occurred in the metal group. Conclusion: Both techniques produced satisfactory outcomes in the treatment of traumatic anterior instability. The biodegradable anchor group could also avoid problems with metal anchors.

Treatment of Transverse Patella Fracture with Minimally Invasive Load-Sharing Patellar Tendon Suture and Cannulated Screws (최소 침습 기법 슬개건 부하 분산 봉합술과 유관 나사못을 이용한 슬개골 횡골절의 치료)

  • Lee, Beom-Seok;Park, Byeong-Mun;Yang, Bong-Seok;Kim, Kyu-Wan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.540-545
    • /
    • 2021
  • A transverse fracture is the most common type of displaced patella fracture requiring surgery. These fractures are commonly fixed with parallel Kirschner wires or screws that cross the fracture line, often with an additional tension band. Nevertheless, conventional fixation methods of patella fractures have prevalent complications caused by the protrusion of wires or pins. These complications necessitate additional surgery for hardware removal, increase medical cost, and can limit the function of the knee joint. This paper reports cases treated with a minimally invasive load-sharing percutaneous suture of the patella tendon. The procedure provides reliable fixation for transverse patella fractures, minimizes soft tissue injuries, preserves blood flow, and reduces postoperative pain. In addition, the procedure also reduces the irritation and pain caused by the internal fixture, thereby reducing the risk of restricted knee joint movement.

Arthroscopic Pull-out Wire Fixation Using Cannulated Screw of Tibial Eminence Fractures (도관 나사못을 이용한 경골 과간 융기 골절의 관절경적 견인 봉합술)

  • Kim, Jong-Min;Kim, Hyung-Gyu;Park, Byeong-Mun;Song, Kyeong-Seop;Jung, Sung-Hoon;Noh, Haeng-Kee;Yoon, Jong-Joo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.254-258
    • /
    • 2009
  • Tibial eminence fracture is caused by distortion, excessive flexion and extension, varus and valgus injury of the knee joint in the form of avulsion fracture. A failure over the exact anatomical reduction of fragment can lead to instability and limitation of joint motion. Recently, a variety of arthroscopic assisted reduction and fixation technique have been used. In the tibial eminence fracture, we created an arthroscopic pull-out wire fixation technique using a cannulated screw that is easy and more convenient than in the conventional technique. So we report this technique with a review of current literatures.

  • PDF

Coracoclavicular Ligaments Reconstruction for Acromioclavicular Dislocation using Two Suture Anchors and Coracoacromial Ligament Transfer (견봉 쇄골 탈구의 봉합 나사못과 오구 견봉 인대 이전술을 이용한 오구 쇄골 인대 재건술)

  • Shin, Sang-Jin;Roh, Kwon-Jae;Jeong, Byoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.46-52
    • /
    • 2008
  • Purpose: This study examined the outcomes of reconstruction of the coracoclavicular ligaments with using two suture anchors and performing coracoacromial ligament transfer in patients with acromioclavicular dislocation. Material and methods: Forty patients with complete acromioclavicular dislocation were included in this study. According to the preoperative radiographs, 5 patients with AC dislocations were diagnosed as type III, 4 patients as type IV and 31 patients as type V. Two 3.5mm suture anchors with four strands of nonabsorbable sutures were separately placed on the anterolateral and posteromedial portion of the base of the coracoid process to stabilize the distal clavicle. The coracoacromial ligament was then transferred to the undersurface of the distal end of the clavicle for augmentation. Results: At a mean follow-up of 28 months, the average Constant score improved to 97 points. All the patients returned to normal life at an average of 3.2 months postoperatively. At the last follow-up, 37 patients achieved anatomical reduction and three patients showed complete redislocation. However, the clinical results of the patients with redislocation were satisfactory. Conclusion: Anatomical coracoclavicular reconstruction using two suture anchors and coracoacromial ligament transfer for treating complete acromioclavicular dislocation is a safe, effective procedure for restoring a physiologically stable acromioclavicular joint.

Effects of Fusion Level for Scioliotic Spine Correction Simulation with Pedicle Screw and Rod Derotation Method (척추경 나사못 고정과 강봉 감염술을 이용한 척추 측만증 교정 해석시 유합 범위에 따른 교정 효과 분석)

  • 김영은;손창규;최형연;하정현;이춘기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.71-76
    • /
    • 2004
  • In order to investigate the Post-operative changes in scoliotic spine according to selection of fusion level a mathematical finite element model of King-Moe type II scoliotics spine system was developed. By utilizing this finite element scoliosis model surgical correction simulation procedures of pedicle fixation and derotation were simulated. In consequence of the calculation by changing the fusion Levels, postoperative changes like Cobb angle, apical vertebrae axial rotation (AVAR), thoracic kyphosis, and rib hump were Qualitatively analyzed. In the analysis of operative kinematics, the decrease or Cobb angle was most prominent in distraction than in deroation. Applying the rod derotation only was not effective in decrease of Cobb angle but just caused increase of At AR and rib hump. From the operative simulation, co-action or distraction and translation during rod insertion has major impact on Cobb angle decrease and maintenance of kyphosis. With rod rotation, Cobb angle decrease was obtained, but combined increase of AVAR and rib hump was simulation observed as well. The case of most extended instrumentation range with 60o rod rotation produced double decrease of Cobb angle, but the increase of rib hump and AYAR occurred corresponding1y. The optimum selection of fusion level was proved as one level less than inflection position of the thoracic spine curvature.

Initial Fixation Power of Human Bone Interference Screw (인간 골 간섭 나사못의 초기 고정력)

  • Kim Jung-Man;Chung Yang-Kook;Kim Yang-Soo;Oh In-Soo;Koh Ihn-Joon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.26-30
    • /
    • 2002
  • Purpose: To estimate the initial and early phase fixation power of the human bone interference screw in reconstruction of the anterior cruciate ligament with bone-patellar tendon-bone allograft. Materials and Methods: The results of twenty eight knees of reconstruction with bone-patellar tendon-bone allograft were analysed in 6 weeks, 12 weeks, 6 months and one year following operation. Physical examination including Lachman test, flexion rotation drawer test and jerk test were performed. The KT-1000 measurement was performed at the same time. In Lachman test 0 $\~$2mm anterior displacement of the tibia was considered normal. The KT-1000 measurement of normal side was compared with operation side and the difference of the two was recorded. The MRI was checked at final follow-up. Results: All but one knee showed normal in physical examination. The failed case showed proximal migration of the graft due to insufficient number of interference screw fixation in widened tibial tunnel. Conclusions: The human cortical bone interference screw showed sufficient initial and early phase fixation power in reconstruction of the anterior cruciate ligament.

  • PDF

Arthroscopic Treatment of Displaced Tibial Spine Fracture in Children (소아에서의 전위된 경골극 골절의 관절경적 치료)

  • Choi, Nam-Yong;Cheong, Hyung-Kook;Koh, Hae-Seok;Han, Suk-Ku;Nah, Ki-Ho;Song, Hyun-Seok;Kim, Bae-Gyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Purpose: To analyze the clinical result of the arthroscopic reduction and fixation for the displaced tibial spine fractures in children and report the utility of the arthroscopic treatment with the review of the literature. Methods: Between December 2000 and July 2004, five patients (average age 9.1 years) received an arthroscopic reduction and fixation of displaced tibial spine fracture. A male-to-female ratio was 3:2 and mean follow-up was 38.2$(13{\sim}56)$ months. All five patients were classified type III by Movers and McKeever classification. The average period from injury to operation was 4.8 days $(3{\sim}8days)$, the avulsed fragment was reduced by operative arthroscopy and fixated by pull-out suture in 3 patients and by cannulated screw in 2 patients. Postoperatively long leg cast was applied for 2 weeks, and then gradual range-of-motion exercise was permitted. Full weight-bearing ambulation was permitted after 6 weeks. The clinical evaluation was performed by range of motion, Lachman and pivot shift test, KT-1000 arthrometer, Lysholm knee score and the modified Feagin score. Results: All five patients had no symptom and recovered full range of motion of the affected knees. Lachman test was positive finding of 1+ laxity in one patient, the others were negative, and all patients were negative findings for pivot shift test. The result of KT-1000 arthrometric assessment is mean maximum side-to-side differences 1.9 mm. Average Lysholm knee score was 99.4. All patients had excellent results in modified Feagin score. Conclusion: Arthroscopic reduction and fixation of displaced tibial spine fracture in children showed excellent result without complication. Both pull-out suture fixation and cannulated fixation provide an effective treatment option for fixation of the displaced anterior tibial spine fracture.

  • PDF

One Anchor Double Fixation (OADF) Technique for Arthroscopic Bony Bankart Repair (두가닥의 봉합사를 가진 봉합나사못을 이용한 새로운 관절경적 골성 방카르트 병변 봉합술)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Bae, Seung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the usefulness of arthroscopic Bony Bankart repair using a One Anchor Double Fixation Technique. Materials and Method: Seventeen patients with a Bony Bankart lesion were treated using the One Anchor Double Fixation Technique (OADF Technique). There were 13 males and 4 females. The average age was 24 years (range 17-42). The average follow-up period was 22.3 months. One 3.0 mm suture anchor with doubly loaded sutures was inserted into the glenoid rim. One suture strand was passed the around the small bony fragment and tied first. Another suture strand was passed through the capsule and tied over the bony fragment. The result was measured using Rowe's evaluation index & KSS score. The glenoid defect & bony fragment were measured by 3D-CT scan. Results: Rowe's evaluation index on the final follow-up showed an overall improvement from an average of 54 (range, 23-71) to 83.4 (range 71-90). Of the 17 cases, 13 were excellent, 3 were good, and 1 was fair. KSS scores showed improvement from an average of 71 (range 49-82) to 92.5 (range 82-94). There were no cases where pain continued to the final follow-up, and no cases being re-dislocated during the follow-up period. For six cases, we confirmed the bony healing of the bony Bankart lesion by CT. Conclusion: Bony Bankart lesion repair using this new method achieves excellent clinical results with low recurrence rates and is considered another choice for bony Bankart lesions.