• Title/Summary/Keyword: 깊이 방향 온도 분포

Search Result 18, Processing Time 0.026 seconds

Characterization on the Geological Structures and Geothermal Gradient Distribution in the Yusong Area (유성온천지역의 지질구조 및 지온분포 연구)

  • 정지곤;서만철;김경수;황형중
    • The Journal of Engineering Geology
    • /
    • v.7 no.3
    • /
    • pp.173-189
    • /
    • 1997
  • A study on the geological structure and geothermal gradient distribution was carried out to evaluate the feasibility of developing a new geothermal field in the Yusong area. It is suggested that geothermal water in the Yusong area is closely related with faults, dykes, and their dipping characteristics with the study of geothermal gradient distribution. A fault of EW direction locates in northern boundary of the study area and another fault of N40{\citc}W$ crosses the EW fault at the western part of the study area. Locations of faults are recognized quite well by lineaments, geophysical exploration and geothermal gradient distribution characteristics. Three sets of dyke are found in the study area. According to the result of the geothermal gradient distribution study, the location of geothermal anomaly belt and dykes coincide each other, and the area has the temperature gradient of larger than 3$^{\circ}C$ between the depths of 0.5m and 1.0m below ground surface. The thermal anomaly belt those temperature gradient is larger than 2.5$^{\circ}C$ between the depths of 0.5m and 1.Om below ground surface is expected in the direction of N80{\citc}W$ in the study area. The dirping of dyke is almost vertical according to the linear distribution of dykes on surface and the results of geophysical survey. From the distribution of geothermal anomaly belt and the locations of dyke, three locations for the development of hot spring water could be recommended and the depth that ensure over 4$0^{\circ}C$ geotheraral water is estimated as 170~200m below the ground surface.

  • PDF

Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns with Loading (섬유혼입공법을 적용한 고강도콘크리트 기둥의 재하 내화시험)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Kim, Heung-Youl
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.473-480
    • /
    • 2009
  • The 180 minutes fire test based on the standard curve of ISO-834 were conducted on three RC column specimens with different constant axial loading ratios to evaluate the fire performance of fiber cocktail (polypropylene+steel fiber) reinforced high strength concrete column. The columns were tested under three loading levels as 40%, 50%, and 61% of the design load. No explosive spalling has been observed and the original color of specimen surface has been changed to light pinkish grey. The maximum axial displacements of three specimens were 1.5~2.2 mm. There was no reduction in load bearing capacity of each specimen exposed to fire and no effect were observed on the fire performance within 61% of the design load. The tendencies of the results with loading, such as the temperature distribution of in concrete and the changes in temperature rise due to the water vaporization in concrete, are very similar to those without loading. The final temperatures of steel rebar after 180 minutes of fire test resulted in 491.4${^{\circ}C}$ for corner rebar, 329.0${^{\circ}C}$ for center rebar, and 409.8${^{\circ}C}$ for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 153.7${^{\circ}C}$ㅍ. The tendency of temperature rise in concrete and steel rebar changed after 30~50 minutes from the starting time of the fire test because the heat energy influx into corner rebar is larger than that into center rebar. The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.

Effect of buoyancy and thermocapillarity on the melt motion and mass transfer for different aspect ratio of flow field in magnetic Czochralski crystal growth of silicon (Cusp 자장이 걸려있는 초크랄스키 실리콘 단결정성장에서 유동장의 종횡비에 따라 부력과 열모세관 현상이 용융물질의 유동과 물질전달에 미치는 영향)

  • 김창녕
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.3
    • /
    • pp.177-184
    • /
    • 2000
  • The effect of the buyancy and thermocapillarity for differnent aspect ratio of flow field on melt motion and mass transfer has been numerically investigated in magnetic Czochralski crystal growth of silicon. During the process of crystal growth, the melt depth of crucible reduces so the aspect ratio of flow field also reduces. Therefore the shape of magnetic field of the flow field changes and the flow pattern also changes significantly. Together with the melt flow which forms the Marangoni convection (or thermocapillary flow) that comes from the inside the flow field, a flow circulation is observed near the corner close both to the crucible wall and the free surface. Due to this circulation, buoyancy effect has been turned out to be local rather than global. As the aspect ratio decreases, the radial component of the magnetic field prevails compared with the axial component in the flow field. Under the influence of this magnetic field, the melt flow and the temperature distribution in a meridional plane tend to depend on the radial position. As the aspect ratio decreases, the temperature gradient near the edge of the crystal decreases yielding smaller thermocapillarity, and the oxygen concentration near the crystal and the oxygen incorporation rate also decrease.

  • PDF

One Dimensional Thermal Elasto-Plastic Analysis Using Layered Beam Theory (적층보 이론을 이용한 1차원 열탄소성 해석)

  • S.I.,Seo;C.D.,Jang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.4
    • /
    • pp.51-57
    • /
    • 1990
  • There exist residual stresses and deformations in welded structures because of nonuniform temperature distribution. The thermal elasto-plastic analysis is necessary to describe the behavor of the structure during welding. In this paper, we calculated the residual stresses and deformations of the welded beam using the I-dimensional layered beam theory. In the previous 1-dimensional analyses, there were restrictions that the equilibrium conditions which were effective only on beams with infinite length were used, and the boundary conditions could not be considered adequately. But, the layered beam theory based on the incremental finite element method, can overcome these restrictions. On the other hand, in the 2-dimensional analysis, the computing time is large because of many degrees of freedom, and there was inaccuracy in the calculation of welding deformations. However, the layered beam theory can take into account the variation of properties along the depth, and can reduce the degrees of freedom considerably in comparision with the 2-dimensional analysis, and shows good agreement with the experiments.

  • PDF

An Analysis of Soil Pressure Gauge Result from KHC Test Road (시험도로 토압계 계측결과 분석)

  • In Byeong-Eock;Kim Ji-Won;Kim Kyong-Ha;Lee Kwang-Ho
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.129-141
    • /
    • 2006
  • The vertical soil pressure developed in the granular layer of asphalt pavement system is influenced by various factors, including the wheel load magnitude, the loading speed, and asphalt pavement temperature. This research observed the distribution of vertical soil pressure in pavement supporting layer by investigating measured data from soil pressure gage in the KHC Test Road. The existing specification of subbase and subgrade compaction was also evaluated with measured vertical pressure. The finite element analysis was conducted to verify the accuracy of results with measured data because it can maximize research capacity without significant field test. The test data was collected from A5, A7, A14, and A15 test sections at August, September, and November 2004 and August 2005. Those test sections and test data were selected because they had best quality. The size of influence area was evaluated and the vertical pressure variation was investigated with respect to load level, load speed, and pavement temperature. The lower speed, higher load level, and higher pavement temperature increased the vertical pressure and reduced the area of influence. The finite element result showed the similar trend of vertical pressure variation in comparison with measured data. The specification of compaction quality for subbase and subgrade is higher than the level of vertical pressure measured with truck load so that it should be lurker investigated.

  • PDF

A Reliable Group Key Re-transmission Mechanism in Ad-hoc Environment (Ad-hoc 환경에서 신뢰적인 그룹 키 재전송 기법)

  • Hong, Suk-Hyung;Kim, Kyung-Min;Lee, Kwang-Kyum;Sin, Young-Tae
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10d
    • /
    • pp.370-374
    • /
    • 2006
  • Ad-hoc 환경의 응용은 재난구조나 회의실 또는 강의실에서의 정보 교환과 같은 그룹 통에서 이용된다. Ad-hoc 환경은 무선 채널을 이용하므로 상대적인 낮은 대역폭과 높은 오류 발생률을 가지게 된다. 따라서 Ad-hoc 네트워크에서는 신뢰적인 전송이 요구된다. 이동 노드는 상대적으로 낮은 성능과 에너지의 제한으로 인해 유선 환경과 같은 신뢰적인 전송 기법을 Ad-hoc 환경에 적용하기에는 문제가 발생한다. Ad-hoc 환경의 무선 채널이 가지는 보안적인 취약성과 높은 에러율을 극복하는 신뢰적인 그룹 키 전송을 위한 재전송 기법을 제안한다. 신뢰적인 트리 형성하기 위해 n차 트리 구조를 이용한다. 손실 감지를 위한 ACK 메시지를 이용하고 손실 복구를 위한 재전송 기법에 대해 연구를 한다. 제안한 신뢰적인 그룹 키 전송을 위한 재전송 기법은 트리의 깊이의 차수가 루트 관리 노드, 서브 관리 노드와 로컬 멤버 노드로 구성되기 때문에 손실 감지와 손실 복구에 대한 연산의 오버헤드가 적다. 루트 관리 노드는 멤버 노드로부터 받은 개인키 정보를 이용하여 그룹 키를 생성하고 그룹 키 부분 정보를 서브 관리 노드에게 전송하고 서브 관리 노드에 대한 신뢰성을 책임진다. 서브 관리 노드는 루트 관리 노드로부터 받은 그룹 키 부분 정보를 로컬 멤버 노드에게 전송하고 로컬 멤버 노드에 대한 신뢰성을 책임진다. 루트 관리 노드와 서브 관리 노드를 관리 노드라 한다. 관리 노드가 신뢰적인 전송을 위해 관리하는 멤버 노드는 전체 그룹에 독립적으로 유지 가능하므로 확장성 및 효율성이 좋다. 관리 노드는 동적인 그룹에 따른 타이머를 설정함으로써 손실 감지에 대한 시간을 줄임으로써 효율적인 손실 감지 및 손실 복구를 한다. 임계값 설정으로 인한 중복 수신에 대한 오버헤드를 줄일 수 있다.신뢰성을 향상 시킬 수 있는 Load Balancing System을 제안한다.할 때 가장 효과적인 라우팅 프로토콜이라고 할 수 있다.iRNA 상의 의존관계를 분석할 수 있었다.수안보 등 지역에서 나타난다 이러한 이상대 주변에는 대개 온천이 발달되어 있었거나 새로 개발되어 있는 곳이다. 온천에 이용하고 있는 시추공의 자료는 배제하였으나 온천이응으로 직접적으로 영향을 받지 않은 시추공의 자료는 사용하였다 이러한 온천 주변 지역이라 하더라도 실제는 온천의 pumping 으로 인한 대류현상으로 주변 일대의 온도를 올려놓았기 때문에 비교적 높은 지열류량 값을 보인다. 한편 한반도 남동부 일대는 이번 추가된 자료에 의해 새로운 지열류량 분포 변화가 나타났다 강원 북부 오색온천지역 부근에서 높은 지열류량 분포를 보이며 또한 우리나라 대단층 중의 하나인 양산단층과 같은 방향으로 발달한 밀양단층, 모량단층, 동래단층 등 주변부로 NNE-SSW 방향의 지열류량 이상대가 발달한다. 이것으로 볼 때 지열류량은 지질구조와 무관하지 않음을 파악할 수 있다. 특히 이러한 단층대 주변은 지열수의 순환이 깊은 심도까지 가능하므로 이러한 대류현상으로 지표부근까지 높은 지온 전달이 되어 나타나는 것으로 판단된다.의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{99m}Tc$-transierrin이 감염 병소의 영상진단에 사용될 수 있을 것으로 기대된다.리를 정량화 하였다. 특히 선조체에서의 도파민 유리에 의한 수용체 결합능의 감소는 흡연에 의한 혈중 니코틴의 축

  • PDF

Application Angle of Defects Detection in the Pipe Using Lock-in Infrared Thermography (위상잠금 적외선 열화상 기법을 이용한 각도별 원전 감육 배관의 결함 검출)

  • Yun, Kyung-Won;Go, Gyeong-Uk;Kim, Jin-Weon;Jung, Hyun-Chul;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.323-329
    • /
    • 2013
  • This perform research of angle rated defect detection conditions and nuclear power plant piping defect detection by lock-In infrared thermography technique. Defects were processed according to change for wall-thinning length, Circumference orientation angle and wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and target pipe's distance fixed 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. Reliability of lock-In infrared thermography data is higher than Infrared thermography data. This through research, Shape of angle rated defect is identified industry place. It help various angles defect detection in the nuclear power plant in operation.

Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique (적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출)

  • Yun, Kyung-Won;Kim, Dong-Lyul;Jung, Hyun-Chul;Hong, Dong-Pyo;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • In the advanced research deducted infrared thermography (IRT) test using 4 inch pipe with artificial wall-thinning defect to measure on the wall-thinned nuclear pipe components. This study conducted for defect detection condition of nuclear small-bore pipe research using deducted condition in the advanced research. Defect process is processed by change for defect length, circumferential direction angle, wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and Target pipe experiment performed to the distance of the changed 1 m, 1.5 m, 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. artificial defect of 4 inch pipe is high reliability in the 2 m, but small-bore pipe is in the 1.5 m from the defect clearly was detected.