• Title/Summary/Keyword: 깃없는 디퓨저

Search Result 10, Processing Time 0.025 seconds

NUMERICAL INVESTIGATION OF THE EFFECT OF THE STAGGER ANGLE ON THE AERODYNAMIC PERFORMANCES IN THE VANED DIFFUSER OF A CENTRIFUGAL COMPRESSOR (디퓨저 깃배치각의 변화에 따른 원심압축기의 공력성능 특성에 관한 수치 연구)

  • Park, T.G.;Jung, I.S.;Chung, H.T.;Park, J.Y.;Kim, S.M.;Baek, J.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.131-135
    • /
    • 2010
  • In the present study, the effects of the stagger angles on the aerodynamic performances in the vaned centrifugal compressor has been investigated by CFD methods. The diffuser vane angles were vane angles were varied in the range of ${\pm}10$ deg. from the intial-design points. The commercial Navier-Stokes solver, ANSYS-CFX were applied to solve the impeller-diffuser flowfields. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

  • PDF

NUMERICAL INVESTIGATION OF THE EFFECT OF THE STAGGER ANGLE ON THE AERODYNAMIC PERFORMANCES IN THE VANED DIFFUSER OF A CENTRIFUGAL COMPRESSOR (디퓨저 깃배치각의 변화에 따른 원심압축기의 공력성능 특성에 관한 수치 연구)

  • Park, T.G.;Jung, I.S.;Chung, H.T.;Park, J.Y.;Kim, S.M.;Baek, J.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.60-65
    • /
    • 2010
  • In the present study, the effects of the stagger angles on the aerodynamic performances in the vaned centrifugal compressor has been investigated by CFD methods. The diffuser vane angles were varied in the range of ${\pm}10$ deg. from the initial-design points. The commercial Navier-Stokes solver, ANSYS-CFX were applied to solve the impeller-diffuser flowfields. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

An Analysis of Flow and Noise for Vacuum Cleaner Centrifugal Fan (진공청소기 원심팬의 유동과 소음 해석)

  • 전완호;이덕주;유기완
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.130-135
    • /
    • 1995
  • 본 연구에서는 30000rpm으로 회전하는 진공청소기 원심팬의 유동장을 임펠러, 디퓨저, 케이싱을 모두 고려하여 해석하였다. 또한 삼차원으로 배출되는 출구를 간단한 sink 패널로 모델하여 출구의 효과를 충분히 고려하였다. 해석된 유동장 자료를 이용하여 먼 거리에서의 음압을 예측하였다. 예측된 음압자료는 FFT를 이용하여 측정된 값과 주파수 영역에서 비교하였다. 또한 진공청소기 원심팬의 측정자료에서 보이는 광역소음특성이 임펠러에서 흘려지는 후류와류의 교란에 의한 임펠러와 디퓨저 깃의 비정상 힘이 주된 원인임을 밝혔다.

  • PDF

An Experimental Study on the Rotating Stall in Vaneless Diffuser of Centrifugal Blower with Radial Type Impeller (반경류형 회전차를 가진 원심송풍기의 깃이 없는 디퓨저 내의 선회실속에 관한 실험적 연구)

  • Kim, Jin Hyoung;Cho, Kang Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1247-1254
    • /
    • 1998
  • The vaneless diffusers are widely used in industrial centrifugal compressors which are required to operate within a wide flow range. When very high pressure gases are handled by centrifugal compressor. rotating stall is a serious problem because of the occurance of large aerodynamic exciting forces. Rotating stall mostly often occurs in the impellers but it can occur in vaneless diffusers as well. In this experimental study, the rotating stall in vaneless diffuser with radial type centrifugal impeller was measured by changing the flow rate with I-type, X-type hotwire. As the result, it was cleared which type of rotating stall of the impeller stall would occur and how many stall cells would appear relating with the flow rate. As the flow rate reduced, the propagation speed of rotating stall was reduced. But the stall cell number unchanged with respect to the flow rate.

A Study on Flow Characteristics and Efficiency in Guide Vane of Diffuser Pump Using PIV Measurement (PIV를 이용한 디퓨저펌프 정익에서의 성능과 유동특성에 관한 연구)

  • 김정환;김범석;김진구;함승덕;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.633-640
    • /
    • 2003
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation Identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

The Flow Characteristics in a Vaneless Diffuser by PIV Measurements (PIV측정에 의한 깃 없는 디퓨저에서의 유동특성)

  • Yoon, Ji-In;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.45-50
    • /
    • 2012
  • The flow characteristics in a vaneless diffuser with a backswept radial impeller have been experimentally investigated according to the variation of discharge flow rate. Particle image velocimetry(PIV) system was applied to measure velocity fields with several operating conditions and on some diffuser horizontal planes. Pressure transducers were installed on hub wall of the diffuser in order to analyze the pressure fluctuations and their corresponding velocity fields. The results show that the location of the main flow center moves from the hub to the shroud side as the flow rate decreases, and the reverse flow is locally generated on the hub side.

Flow characteristics at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동 특성)

  • Hong, Soon-Sam;Kang, Shin-Hyoulg
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.36-44
    • /
    • 2000
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A hot-film probe and a high response pressure transducer are used to investigate the flow at impeller exit and vaneless diffuser region for design and off design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, design, and numerical analysis of pumps.

  • PDF

NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER (고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측)

  • Park, T.G.;Chung, H.T.;Park, J.Y.;Sung, B.I.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

PERFORMANCE BY WIDTH CONTRACTION IN VANELESS DIFFUSER OF CENTRIFUGAL COMPRESSOR BY COMPUTATIONAL FLUID DYNAMICS (전산해석을 통한 원심압축기용 디퓨저의 폭변화에 따른 성능 연구)

  • Lee, S.C.;Lee, W.S.;Shin, Y.H.;Chung, J.T.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.136-141
    • /
    • 2010
  • This study describes effects of width contraction in vaneless diffuser on the performance of centrifugal compressors using commercial CFD code. Numerical analysis for three different diffusers such as Parallel, half contraction, and full contraction was performed. The results show that the performance of the centrifugal compressor is improved through the use of the diffusers with width parallel in high flow rate. The width contraction of diffusers is influenced static pressure rises. Comparison with the experimental data shows agreement.

  • PDF

An Experimental Study on the Flow at the Impeller Exit of a Centrifugal Pump (원심펌프의 회전차 출구 유동에 관한 실험적 연구)

  • Kang, Shin-Hyoung;Hong, Soon-Sam
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.234-241
    • /
    • 1999
  • The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. However, it is not easy to measure the flow at the impeller exit and evaluate the impeller performance since there is usually strong interaction between the impeller and the volute casing. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A 3-hole Cobra probe is used to investigate the flow at impeller exit and vaneless diffuser region for design and on design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, desist and numerical analysis of pumps.

  • PDF