Comparison of Standards for healthcare Facilities and Environmental Investigation to Analyze Guidelines and Current Status of Healthcare Facilities (의료시설 관련 기준 비교와 환경 조사를 통한 의료시설 지침 및 현황 분석)

  • Jo, Yelim;Kim, Gihoon;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.51-60
    • /
    • 2022
  • Purpose: This study aims to analyze and supplement the standards related to healthcare facilities, negative pressure isolation wards, and emergency treatment facilities. In addition, through environmental investigations, analysis of emergency remodeling cases centered on the structural and HVAC characteristics of healthcare facilities is conducted. Methods: Domestic and foreign standards related to healthcare facilities were analyzed. Field investigations and architectural drawing analysis of general and emergency treatment facilities were conducted. Results: Healthcare facilities have different space classifications and air conditioning methods depending on the site situation. Emergency treatment facilities are classified into cases where the HVAC system is remodeled and portable negative pressure unit is installed, and some facilities did not meet the standards for differential pressure and air change rate. Implications: When developing emergency remodeling technology, remodeling and safety evaluation guidelines, it is considered possible to propose clearer guidelines for emergency remodeling treatment facilities for infectious diseases in Korea by referring to the results of this study.

Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era (포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석)

  • Lee, Sejin;Lee, Wonseok;Kim, Eunseok;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

Study on Suggestion of Smoke-proof System Using a Restroom for a Refuge Space (화장실 이용 피난공간의 방연시스템 제안 및 실규모 실험)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.61-66
    • /
    • 2012
  • In restroom on high-rise building, exhaust system comprising the blower and duct is installed to discharge the odor and the water is suppled. Thus the restroom with fire and flame protection system may be used as refuge area in a fire situation. The study presents the smoke-proof system which operates such that the exhaust system to discharge the odor is converted to air supply system and appropriate pressure difference between the restroom and the accommodation is maintained. Also real-scale test facilities of smoke-proof system for refuge space using a restroom are installed on 5-story smoke control test building and experiments for evaluating the operational performance of smoke-proof system are carried out.