• Title/Summary/Keyword: 기표와 기의

Search Result 45, Processing Time 0.026 seconds

A Semiotic Study on the Background Color of Fantasy Game (판타지 게임 배경 색채에 대한 기호학적 연구)

  • Lim, Cholong;Paik, Chul-Ho
    • Journal of Korea Game Society
    • /
    • v.18 no.6
    • /
    • pp.49-58
    • /
    • 2018
  • This study analyzes semiotic aspects of game concept art which is developed considering individual 's color experience. The six stages of Frank H. Mahnke's color pyramid are roughly classified into three categories, and how the game concept art meets each stage. Using the Roland Barthes's mythological-symbolic model of meaning, The meaning of righteousness and the characteristics of newly derived symbols. The results showed that colors could make the background stage more recognizable or intended to have a particular impression. In this way, game concept art, in which what is intended to be implemented in game development, can identify various functions and possibilities of game concept art, such as presenting game convenience as well as impression through a combination of various colors.

A study of the Semiotic Features of Korean Realistic Films Focused on the <Silenced> (한국 리얼리즘 영화에 나타난 기호학적 특징 영화 <도가니>를 중심으로)

  • Zhou YuFeng;Choi Won-Ho
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.909-917
    • /
    • 2023
  • Semiotic theory plays a vital role in the cognition of realistic films. Realistic films aim to reflect events and situations in real life, and arouse the audience's thinking about real problems through realistic depiction. In this process, the theory of semiotics helps to reveal the symbolic elements in the film and the profound meaning behind them. This study focused on the realism movie 도 가 니 "(Silenced), on the basis of the theory of saussure's semiotics, combined with its proposed the concept of "signifier" and "mean", through the study of arbitrariness and secondary film symbol sign system, designed to dig deeper into the symbolic meanings in the movie, and their cultural significance and social evaluation. By analyzing the implied narrative structure, meaning structure and ideology in the film, this paper probes into the influence and effect of mass culture on society and reveals the potential information conveyed by symbols in the film. This study aims to provide creative insights and explanations to provide useful references for research in related fields.

History and Archives : Colleagues or Strangers? (역사학과 기록학 학문의 인연, 학제의 괴리)

  • OH, Hang-Nyeong
    • The Korean Journal of Archival Studies
    • /
    • no.54
    • /
    • pp.179-210
    • /
    • 2017
  • By redefining the concept of history, my colleagues and I have reformed our department in terms of curriculum and faculty members. This paper is a report of some of the conclusions that we have obtained from this procedure. Despite a long relationship, two disciplines do not seem to match or complement each other in the Korean education system. We believe that this is due to the fact that the Department of Korean History has focused on "national history (NH)." By conferring a privilege on NH, persons, families, societies, regions, and others were removed from NH. To make matters worse, a biased view that history is just an interpretation has prevailed, and the empiricism of history was weakened, which brought about an indifference in keeping records and archives. In East Asia, "history" means both modern history and archives. The concern about the authenticity of records did not come from H. Jenkinson or L. Duranti, and not even from the electronic environment or the Public Records Act of 1998. Key concepts such as records, documents-archives, manuscripts, authenticity, compilation-appraisal, arrangement, and description are different from their signifiant but are same or similar to their $signifi{\acute{e}}$. In case of "provenance" and "original order," they are used in education and practice in the traditional archives. History includes the recording, archiving, and the story or historiography of an event. In this context, the Department of Korean History should contain a more archives-oriented curriculum and select an archival-trained faculty. On the other hand, the department has accumulated long-term experience with appraisal and description of records; thus, archival science should absorb the criticism of the material. History will be shaken without the help of archives, while archives will lose their root without history. We are at the point in which we need to be reminded why we want to be a historian or an archivist, and for this, the more colleagues, the better.

The Surgical Results of Stage I Lung Cancer (제 1기 폐암의 수술성적)

  • 김길동;정경영;홍기표;김대준
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.982-987
    • /
    • 1998
  • Background: Surgical resection is the standad therapy for the stage I lung cancer. We analysed the risk facturs of stage I lung cancer patent and tryed to establish more effective and aggressive treatment modality. Materials and methods: A detailed analysis was undertaken to evaluate the surgical results and to define the risk factors associated with the recurrence and the survival time in 146 consecutive patients with stage I lung cancer who were diagnosed, and resected at Yonsei Medical Center from January 1990 to December 1996. Results: There were 115 males and 31 females. Their ages ranged from 27 to 79 years(mean age:58.9$\pm$9.3 years). The histologic types were squamous carcinoma in 72 cases(49.3%) and adenocarcinoma in 45 cases(30.8%). A pulmonary resection and mediastinal lymph node dissection were done in all cases. A lobectomy was performed in 96 cases(65.7%) and a pneumonectomy in 48 cases(32.9%). There were 5 operative mortalities(3.4%) and complications occured in 24 cases(16.5%). The overall 5-year survival was 64.1%, and survival time did not depend on the type of operation or histologic type. Significant predictors of decreased survival were visceral pleural invasion(p=0.0079), T2 lesion(p=0.0462), and tumor size($\geq$5 cm) in adenocarcinoma(p=0.0472). The overall incidence of recurrence was 33.3%(47 cases; local or regional 6.4%, distant 26.9%). Almost all recurrences(44cases) occurred in T2 lesions. The distant organs that failed were the contralateral lung in 13 patients, the brain in 12, the bone in 10, and other organs in 3. Conclusions: even in stage I lung cancer, we suggest that postoperative adjuvant therapy is recommended in patients with poor prognostic factors such as visceral pleural invasion, T2 lesions, and a tumor size($\geq$5 cm) in the adenocarcinoma.

  • PDF

Development of a Groundwater Sampler and Test in a Well Affected by Seawater Intrusion (지하수 샘플러 개발 및 해수침투 관측정에서의 평가)

  • Lee, Bong-Joo;Moon, Sang-Ho;Kim, Gee-Pyo;Kim, Yong-Cheol;Kim, Yong-Je;Koh, Gi-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.331-338
    • /
    • 2008
  • A new ground water sampler was developed and evaluated for target depth sampling under most rigorous field conditions. This new concept sampler comprises an air-cylinder, a hypodermic needle and a sampling bottle. Pressurized air or nitrogen gas can be used as a mechanical power source to operate the sampler. The air-cylinder is used to jab the hypodermic needle into the rubber cap of the sampling bottle. The hypodermic needle functions as a pathway to inject groundwater into the sampling bottle. Field test was conducted in a seawater intrusion monitoring well located at Handong district of Jeju Island. Water qualities in this well are periodically changed from the effects of sea water. Water sampling fir the same target depth in this well were tried at various times, and variations in electrical conductivity and pressure at the inside and outside of the sampler were measured using CTD divers. We found that the device could collect water samples only when it was actuated, and the pattern and range of variations in electrical conductivities and pressures measured at the inside and outside of the sampler were nearly identical. These results indicate that water samples using the sampler presented in this study represent correctly water qualities in which the samplings were made at a specific target depth in a well.

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

The relation between Movement working as a Grouping clue in Moving Picture and Semantic structure forming (동영상에서 그룹핑(grouping) 단서로 작용하는 움직임(Movement)과 의미구조 형성의 관계)

  • Lee, Soo-Jin
    • Archives of design research
    • /
    • v.19 no.5 s.67
    • /
    • pp.119-128
    • /
    • 2006
  • The scale of visual expression has expanded from freeze frame to motion picture as media have developed. Moving pictures such as animation, movies, TV CM and GUI become formative elements whose movement is necessary compared to freeze frame as apparent movement phenomenon and unit structure such as short and scene appear. Therefore, of formative elements such as a shape, color, space, size and movement, movement is importantly distinguished in the moving image. The expression and form of image as a relationship between the signified and signifier explained by Saussure are accepted as a sign by mutual complement even though they limit the content. This makes it possible to infer that the formal feature of movement participates in the message content. To verify this, the result of moving picture visual perception experiment based on the gestalt grouping principle result shows that 70-80 percent of subjects think that 'movement' is the important grouping clue in perception. Movement affects the maintenance of the context of message content in the communication process when the meaning structure of moving picture is analyzed based on the structural feature. The identity can be maintained with if there is a movement with similar directive point even if the color and shape of people, things and background are changed. Second, the clarity of the content is elevated by a distinguished object as a figure by movement. Third, it acts as a knowledge representation which can predict similar movement process of next information processing. Forth, movement gives the content consistency even though more than two scenes have fast switch and complicated editing structure like cross-cutting. Movement becomes a clue which can make grouping information input by visual perception reaction. Also, it gives the order to the visual expression which can be used improperly by formation of structural frame of image message and has the effectiveness which elevates the clarity of signification. Moving picture has discourse with several mixed unit structures because it fundamentally contains time and the common and distinguished expression is needed by media-mix circumstances. Therefore, by the application of gestalt grouping principle to moving picture field, movement becomes the more distinguished than other formative elements and affects the formation of meaning structure. This study propose a viewpoint that develops structural formative beauty and new image expression in the media image field.

  • PDF

A study on Palpation of the back-shu points (배유혈(背兪穴) 안진(按診)에 관(關)한 고찰(考察))

  • Hong, Mun-Yeup;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.155-173
    • /
    • 2000
  • The diagnosis in Oriental medicine is done by inspection, auscultation and olfaction, interrogation, four diagnostics of pulse feeling and palpation, and various system of identification like identification according to Qi(vital energy), Xue and body fluids, identification according to fair principles, identification according to principles of Wei, Qi, Ying and Xue, identification according to Sanjiao(the triple heater), identification according to four type physical constitution. Sometimes, symptoms and diagnosis techniques according to symptoms is selectively applied for the diagnosis. Among them the pulse feeling and palpation diagnosis technique using the sense of finger and palm of the hand is divided into feeling of pulse and palpation and pressing maneuver. Pressing maneuver is a diagnosis technique pressing and rubbing the affected part in order to attain data of identification including inside and outside condition of the body with regard to the nature, condition and relative seriousness of disease. There are palpation of the skin, palpation the hand and foot, palpation the chest and the abdomen, palpation shu points in pressing maneuver. The diagnosis of the Back Shu points is a technique to examine the change of disease condition from pressure ache, spontaneous ache, tension, relaxation, solidification revealed through channels and collaterals. I investigates starting disease and an attack of disease of twelve pulse and pulse condition through the study relative to the substance and technique of pressing maneuver, and adjusts diagnosis techniques of a region for acupuncture and matters to be attended. The conclusions are as follows. 1. The Shu or stream points in which pathogenic factors go are important to medical treatment of dormant diseases like bowels disease, cold symptom complex and insufficiency symptom complex. 2. Disease classified by system is diagnosed by the condition of process part like pro-trusion, cave-in, tension, relaxation, pressure ache through palpating the Shu or stream points, that is pressing upward or downward left and right sides of the backbone process by hands. 3. In real clinic pressing maneuver of one's back side is very important to patient's diagnosis treatment. Thus, pressing maneuver of one's back side have to be done without omission. 4. Diagnosis must be accomplished through the perception about the diversity of diagnosis technique of bowels disease, the exact knowledge about pressing maneuver of one's back side for enlargement of treatment range and rising of treatment rate, and pressing maneuver of the Shu or the stream points.

  • PDF

Usefulness Assessment of Automatic Analysis Program for Flangeless Esser PET Phantom Images (Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가)

  • NamGung, Chang-Kyeong;Nam, Ki-Pyo;Kim, Kyeong-Sik;Kim, Jeong-Seon;Lim, Ki-Cheon;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.63-66
    • /
    • 2009
  • Purpose: ACR (American College of Radiology) offers variable parameters to PET/CT quality control by using ACR Phantom. ACR Phantom was made to evaluate parameters which are uniformity, attenuation, scatter, contrast and resolution. Manual analysis method wasn't good for the use of QC because values of parameter were changed as it may user and it takes long time to analysis. Ki-Chun Lim, a nuclear scientist in AMC, developed program that automatically analysis values of parameter by using ACR Phantom to overcome above problems. In this study, we evaluated automatic analysis program's usability, through the comparing SUV of each method, reproducibility of SUV when repeated analysis and the time required. Materials and Methods: Using Flangeless Esser PET Phantom, the ideal ratio of 4 : 1 hot cylinder and BKG but it actually showed a ratio of 3.89 to 1 hot cylinder and BKG. SIEMENS Biograph True Point 40 was used in this study. We obtained images using ACR phantom at Fusion WB PET Scan condition (2 min/bed) and 120 kV, 100 mAs CT condition. Using True X method, 3 iterations, 14 subsets, Gaussian filter, FWHM 4 mm and Zoom Factor 1.0, $168{\times}168$ image size. We obtained Max. & Min. SUV and SUV Mean values at Cylinder (8, 12, 16, 25 mm, Air, Bone, Water, BKG) by automatic program and obtained SUV by manual method. After that, we compared manual and automatic method. we estimate the time required from opened the image data to final work sheet was completed. Results: Automatic program always showed same result and same the time required. At 8, 12, 16 and 25 m cylinder, manual method showed 6.69, 3.46, 2.59, 1.24 CV values. The larger cylinder size became, the smaller CV became. In manual method, bone, air, water's CV were over 9.9 except BKG (2.32). Obtained CV of Mean SUV showed BKG was low (0.85) and bone was high (7.52). The time required was 45 second, 882 second respectably. Conclusions: As a result of difference automatic method and manual method, automatic method showed always same result, manual method showed that the smaller hot cylinders became, the lager CV became. Hot cylinders mean region size, the smaller hot cylinder size becomes we had some trouble in doing ROI poison setting. And it means increase in variation of SUV. The Study showed the time required of automatic method was shorten then manual method.

  • PDF

Application of Electrical and Small-Loop EM survey to the Identification of the Leachate at a Waste Landfill in Jeiu Island (제주도 쓰레기매립장 침출수 조사를 위한 전기 및 소형루프 전자탐사의 적용)

  • Song Sung-Ho;Yong Hwan-Ho;An Jung-Gi;Kim Gee-Pyo
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.3
    • /
    • pp.143-152
    • /
    • 2003
  • Among the various geophysical approaches to identify the leakage of leachate with conductivity variation, conventional electrical resistivity survey has been mainly used at waste landfill. We adopted small-loop electromagnetic (EM) survey using multi-frequencies in parallel with electrical resistivity survey to delineate the leakage of leachate through the shallow soil layer at a waste landfill in Jeju Island, and also with self-potential monitoring to detect the streaming potential produced by the movement of leachate. There were no evidences of leakage from waste landfill according to the results of the electrical resistivity survey and SP monitoring, and it was also true from the results of water quality analysis at stream around waste landfill periodically. On the other hand, the results of one-dimensional inversion of spatially-filtered small-loop EM survey data showed the anomalous zone of low resistivity with depth both around and inner waste landfill.