• Title/Summary/Keyword: 기포 크기

Search Result 200, Processing Time 0.028 seconds

Interface Chemical and Hydrodynamic Aspects of Deinking Process Using Flotation for Waste paper Recycling(II) (부유선별법을 적용한 탈묵공정의 계면화학적 및 수력학적 원리(II) -수력학적 원리를 중심으로-)

  • Sun-Young Park
    • Resources Recycling
    • /
    • v.5 no.4
    • /
    • pp.11-16
    • /
    • 1996
  • In the flotation system for deinking process, the ink partcles musl collidc with the air bubbles for adhesion The probability of bubble-particle collision is largely dependent on the hydrodynamic conditions The main reason for the very small ink particles not to be able to float easily may be tound in the hydrodynamic effects, which make small ink particlcs move following the slreamlines around the bubbles rather than achually collide with bubbles. Also. the low floatabdily of the large and heavy ink particles is due to the gravity force and viscous drag which affect uprising molinn of particles through the liquid. Therefore, it is vely important to control not only the surface chemical conditions but the hydrodynamic conditions in practical floialion system

  • PDF

Development of glass bulb for sprinkler head system (스프링클러용 유리발브의 개발)

  • Kim, Byung-Cheol;Joung, Hoon-Choul;Seo, Yo-Won;Myung, Young-Sup
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.144-147
    • /
    • 2008
  • A glass bulb is the most reliable and simplest device for a fire sprinkler head system. We had developed an accurate glass bulb. The glass bulb is composed with a glass ampoule, liquid filled within the ampoule and an air bubble in the liquid. The first step of the development was to establish a stable mass production system for uniform glass ampoule. The second step is to optimize the composition of the liquid and the size of the bubble. It was also a difficult problem to devise manufacturing process to form uniform bubble size. The final step for the development is to control the mechanics for glass breaking by surface treatment for the glass bulb.

  • PDF

Flow Field across Multiple Fluid Sphere in the Low Kundsen Number Regime (저 누드센 영역에서의 복합 유체구의 유동장)

  • 정창훈;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.397-398
    • /
    • 2003
  • 대기 중 분진을 제거하는 방식으로 여과 이론을 적용할 수 있는 경우는 섬유 여과기, 입자상 여과기, 액적에 의한 습식 세정기 그리고 기포를 이용한 분진 제거 방법 등을 들 수 있다. 이러한 여과 원리를 이용한 집진 설비를 설계하는데 있어, 액적 또는 기포 주위의 유동장을 정확히 파악하는 것은 매우 중요하다. 특히, 포집구의 크기가 작아지고 화학적으로 반응성을 갖는 고온의 함진가스가 유입되는 경우 및 저압에서 운영되는 경우에 누드센수(Knudsen number)의 영향을 무시할 수 없는데 이러한 영역을 저 누드센 영역(low Kundsen number regime)이라고 한다(Lee et al., 1978). (중략)

  • PDF

Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet (초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가)

  • Kim, Hyun-Jin;Park, Il-gun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • A road structure washing vehicle equipped with a 4 HP, 80 LPM ultrafine bubble generator was used to clean a tunnel wall and the surface of the surrounding structure, consisting of concrete and tiles, in a heavy traffic area around an apartment complex in the city. Ultrafine bubbles were generated by supplying air at 2 to 3 LPM and using a specially designed nozzle, whereas fine bubbles made by an impeller in a gas-liquid mixing self-priming pump were produced with an average diameter of 165.4 nm and 6.81 × 107 particles mL-1. Using a high pressure washer gun that can perform high-pressure cleaning at 150 bar and 30 LPM, ultrafine bubbles were used to wash dust adsorbed on the surface of the road structures. The experimental analysis was divided into before and after washing. The samples were analyzed by applying ISO 8502-3 to measure surface contamination of dust adsorbed on the surface. Using the transparent tape attached to the surface, the removal rate was calculated by measuring the weight of the dust, and the number of particles was calculated using the gravimetric method and the software, ImageJ. The results of the experiment showed that the number of dust particles adsorbed on the tile wall surface before and after washing were 3,063 ± 218 particles mL-1 and 20 ± 5 particles mL-1, respectively, with weights of 580 ± 82 mg and 13 ± 4 mg. Particles on the surface of the concrete structure before and after washing were 8,105 ± 1,738 particles mL-1 and 39 ± 6 particles mL-1, respectively, with weights of 1,448 ± 190 mg and 118 ± 32 mg.

Effect of Water on the Lightweight Air-Mixed Soil Containing Silt Used for Road Embankment (도로성토체로 사용된 실트질 계열의 경랑기포혼합토에 대한 물의 영향)

  • Hwang, Joong-Ho;Ahn, Young-Kyun;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.23-32
    • /
    • 2010
  • This study was especially conducted to find out the characteristics of the lightweight air-mixed soil (slurry density 10 kN/$m^3$) containing silt related to water. Compression strength, permeability, and capillary height of the lightweight air-mixed soil were studied, and also to support these studies, the structure of that soil was analyzed in detail. Air bubbles of various sizes are inside the lightweight air-mixed soil, and its distribution in a location is almost constant. A numerous tiny pores are inside the air bubbles so that the lightweight air-mixed soil can be saturated with water. Porosity is also estimated through the image analysis. Peak strength of the lightweight air-mixed soil is not dependent on water, but behavior of stress-strain is affected by the water. Permeability is about $4.857{\times}10^{-6}cm/sec$, which is a little bit higher than the clay's permeability. Capillary rise occurs rapidly at the beginning of the test until the lapse of 100 minutes and then its increase rate becomes slow. The capillary rise causes the increase of the density of the lightweight air-mixed soil, and thus it is required to pay attention to this phenomenon during structure design and maintenance of the lightweight air-mixed soil.

Size Characteristics of Micro-bubbles According to Applied Voltage and Electrode materials (전해부상에서 전압과 극판 재질에 따른 미세기포의 크기 특성)

  • Park, Yong-hyo;Han, Moo-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.16 no.6
    • /
    • pp.663-669
    • /
    • 2002
  • Electro-flotation (EF) has shown advantages, such as a high removal efficiency and easy control of bubble generation, over dissolved air flotation. However, the fundamental characteristics of the process have not been investigated in detail. According to recent modeling results from trajectory analysis, the size of the bubble is one of the most important factors that affect the efficiency of collision between bubble and particle. In this paper, the size characteristics of bubbles generated from EF under various conditions are measured using a new method for bubble size measurement, the Particle Counter Method (PCM). The size of the generated bubbles was found to be constant with respect to applied voltage but to vary with the electrode materials. These results and their implications are discussed.

Effects of Operating Variables on the Conversion of Meta Boric Acid Formation in a Bubble Column Reactor (기포탑 반응기에서 조작변수가 meta 붕산 생성반응 전환율에 미치는 영향)

  • Cho, Soo-Haeng;Do, Jae-Bum;Kang, Y.
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.573-579
    • /
    • 1996
  • Effects of operating variables on the conversion of the formation reaction of meta boric acid from ortho boric acid in a laboratory-scale bubble column reactor were investigated to obtain the basic data which are indispensable for the design, scale-up, control, development and operation of industrial bubble column reactors. Reaction time and pressure, particle size of reactant and gas flow rate were chosen as experimental variables. Effects of the experimental variables on the gas holdup in the bubble column reactor were also discussed in relation to the conversion of reaction. From the results of this study, the optimum conditions were drawn as follows : Reaction time ; 35~40(min), reaction pressure ; 92~95(kPa), particle size ; under $0.6{\times}10^{-3}(m)$, gas flow rate ; 0.07~0.08(m/s).

  • PDF

A Study on the Flow Characteristics of Bubbles in a Fluidized Bed (유동층에서 기포의 유동특성에 관한 연구)

  • 김용섭
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.117-124
    • /
    • 1996
  • A fluidized bed combustion chamber is widely used to incinerate waste material. The most important factor designing the incinerator is the flow characteristics in a fluidized bed, because combustion efficiency is influenced by the flow characteristics. This paper has invesitigated the flow characteristics of bubbles in fluidized bed by means of meassuring a pressure fluctuation in the fluidized bed. A pressure probe system has used to measure the pressure. The data concerned with bubble rising velocity, bubble size, distribution of bubbles and frequency of bubble generation or decay are obtained to find the flow characteristics of bubbles in the fluidized bed. The result obtained from this experimental study can be used to design the fuel feeding system of fluidized bed combustion type incinerator. And it is possible to predict the mixing of waste material and fluidizing material.

  • PDF

전기부상법을 이용한 토양세정 유출수 중 유수분리에 관한 연구

  • 소정현;최상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.99-102
    • /
    • 2002
  • 전기분해에 의한 부상현상을 이용하여 토양세정 후 발생되는 유출수 중의 유수를 분리하기 위한 적정 운전조건에 관하여 고찰하였다. 전압에 의한 유수분리 효율을 관찰한 결과, 전기분해 1시간 후 3V의 전압만으로도 88% 정도의 제거율을 나타내었으며 6V 이상의 전압에서는 90% 정도로 거의 비슷한 제거율을 나타내어 대부분의 에멀젼이 분리됨을 확인할 수 있었다. 동일조건에서는 전기분해 시간이 경과될 수록 분리효율이 향상되었으며, 전극 간격이 넓어질수록 같은 효율을 얻기 위해 소요되는 전압의 크기가 커짐을 알 수 있었다. 전기분해 시 양극에서는 OH$^{-}$의 방전으로 발생되는 산소에 의해 산화반응이 일어나며, 음극에서는 H$^{+}$가 방전되어 발생되는 수소에 의해 환원반응이 일어나며 미세한 기포가 형성된다. 유분의 부상분리 현상은 유분의 (-)charge와 전기분해에 의해서 발생되는 양이온의 결합으로 인한 중화반응 및 음극에서 발생되는 미세 수소기포로 인만 부상분리가 대부분을 차지하며, 전압 및 전기분해 시간이 증가하고 전극 간격이 좁을수록 음극에서 발생되는 미세기포의 양이 증가되어 부상효과가 크게 나타나는 것으로 판단된다. 전극 종류는 구리 > 알루미늄 > 철 > 티타늄 순으로 효율을 나타내었으며, 이는 양극으로 사용된 이러한 금속들의 전기전도도 차이에 의해 일어나는 현상으로 판단된다

  • PDF

An Experimental Study on the Performance Evaluation of Lightweight Foamed Concrete According to Size and Replacing Ratio of Artificial Lightweight Aggregate (인공경량골재 크기 및 혼입량에 따른 경량기포콘크리트의 물리적 성능 평가에 관한 실험적 연구)

  • Jeong, Seong-Min;Yun, Chang-Yeon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.162-163
    • /
    • 2017
  • This study investigated the properties of lightweight foamed concrete by using synthetic foaming agent and artificial lightweight aggregate. The effects of artificial lightweight sizes on the compressive strength, density and pore structure of the concrete were investigated. The samples were assessed by MIP analysis and simultaneous SEM was used to study their pore distribution. This study showed the improvement of important properties of lightweight foamed concrete. Lower pore distribution and correspondingly higher compressive strength values were reached. This is for the purpose of providing basic data for the use of lightweight foamed concrete through improvement on the problem such as unstability, falling in fluidity and the strength of existed foaming agent.

  • PDF