• Title/Summary/Keyword: 기체주입

Search Result 223, Processing Time 0.029 seconds

Stability of premixed double concentric jets flame with a recirculation zone (재순환역을 수반하는 동축분류예혼합화염에 관한 연구)

  • 이등헌일;송규근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.145-153
    • /
    • 1987
  • Stability limits of a double concentric jets flame and the structure of recirculation zone formed behind a thick burner rim were investigated. To control the flame stability, swirled secondary air flow ranging 0.13-0.71 of swirl number, and air, fuel, and mixture gas injection from an injection coaxial slit set on burner rim were examined. Flame stability limits, flame shapes, lengths of recirculation zone, temperature distributions, residence times, air ratios in the recirculation zone were measured. The following results were obtained. (1) Lean limits were considerably widened by a strong swirl because the recirculation zone was enlarged. (2) At fuel injection as well as mixture injection, lean limits were also extended. But, air injection had no effect on stability limits. (3) Injected gas seems to diffuse into the recirculation zone through its outer boundary surrounded the secondary air. Therefore, chemical structure in the recirculation zone with air injection coincides with that without injection. (4) Injection position had no effect on flame stability limits.

실리콘 다이오드를 적용한 다채널 중성 입자 분석기 개발

  • Cheon, Se-Min;Jwa, Sang-Beom;Gang, In-Je;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.211-212
    • /
    • 2011
  • 플라즈마를 제어하기 위해서는 플라즈마의 온도, 밀도, 에너지 분포등과 같은 플라즈마의 특성을 정확히 측정할 수 있어야한다. 핵융합발전에서는 플라즈마를 발생하기 위하여 플라즈마의 온도, 밀도 등 각종 변수들을 시공간적으로 계측, 분석할 수 있는 진달설비를 사용하고 있으며, 정확한 플라즈마 제어와 측정을 위한 새로운 진단기술을 개발하고 있다. 그리고 중요한 변수중에 하나인 플라즈마 이온온도를 측정하기 위해 중성입자 검출법이 잘 알려져 있다. 이 실험은 수소 중성입자가 토카막 내부의 플라즈마 이온과 충돌하면서 생성된 고속 중성입자의 에너지를 분석하는 실험이다. 본 연구의 실험방법은 수소 중성입자를 이온빔 장치에서 이온화 시킨 후 자체 제작한 가속기를 통하여 가속시켜 에너지 특성을 분석을 하는 것이다. 본 연구의 실험장치로 에너지 교정용 100 keV 이온빔 소스를 제작 하였고 이온빔 장치 내부에 수소기체를 주입하고 기체방전을 일으켜 플라즈마를 발생시켰다. 이온빔 외부에는 팬을 설치하고 전도성이 강한 물 대신 전도성이 약한 오일을 사용하여 냉각 하였다. 이온빔 장치와 결합될 이온 가속장치는 지름 300 mm, 두께 2 mm의 원형 구리판을 여러층으로 쌓아 전극으로 제작하였고 전극과 전극 사이에서 코로나 방전과 스파크를 방지하기 위해 전극 둘레에 코로나링을 설치 하였다. 또한 전극 사이마다 1G${\Omega}$의 저항을 설치한 후 고전압을 생성하여 이온 가속 효율을 증대시켰다. 진공시스템으로는 Alcatel사의 CFF100 터보분자 펌프와 우성진공사의 MVP24 진공로타리펌프를 결합하여 사용하였으며, 진공도측정은 Alcatel사의 ACS1000 장치를 사용하였다. 고진공후 고속 중성입자의 이온화와 에너지 측정을 위한 전하교환기를 설치하였다. 전하교환기로는 진공시스템을 별도로 설치하고 비용이 비교적 많이 드는 기체형 전하교환기 대신 소형화가 가능하고 유지보수가 좋은 고체형 전하교환기 제작하여 실험 하였다. 전하교환기에서 이온화된 고속 중성입자가 전기장이나 자장에 영향을 받았을때 에너지분포를 디텍터를 통해 측정하였다. 즉, 이온화된 중성입자의 에너지가 실리콘 다이오드를 통해 전압 펄스 신호로 변환되고 이차 증폭기를 통해 전압 펄스 신호들이 증폭한다. 에너지 측정을 위한 디텍터는 소형화가 가능하고 비용이 비교적 적게 드는 실리콘 다이오드를 설치하였다. 본 연구결과 중성입자 에너지 분석 장치가 실제 핵융합 장치의 플라즈마 이온온도와 특성 측정에 적용할 수 있으며, 앞으로 개발될 여러 형태의 응용 플라즈마 발생장치의 플라즈마 진단에 이용될 것으로 기대한다.

  • PDF

Development and Characteristic Study of a Portable Gas Chromatography (소형 GC 모듈의 개발 및 특성)

  • Lee, Myeong-Gi;Oh, Jun-Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.157-162
    • /
    • 2011
  • In the present study, we developed a portable GC module for real-time, quantitative determinations of gas mixtures in air sample. Capillary or packed column was coiled together with a heater wire and thermocouple in a small case. Together with the small and light weight sensors and valves as well as the rechargeable carrier gas canister, which permits collection and separation of samples, this system can determine the components of complex mixtures of air contaminants at low concentrations with a duty cycle of 10 min. When measured the various samples with a FID and TCD, the system showed, for a capillary column, a good resolution (R=8.3), high sensitivity, reproducibility, and linear dynamic range greater than three orders of magnitude. These results indicate that the portable GC module is expected to be used for a wide range of applications, particularly for in situ environmental monitoring, chemical processes, and regulation of contaminant emission.

Quality Characteristics of Pork Belly Meat Stored in a Container Automatically Controlled under High CO2 Atmosphere (고 CO2농도 기체조성으로 자동제어된 용기에 저장된 삼겹살의 품질특성)

  • Soo Yeon, Jung;Dong Sun, Lee;Duck Soon, An
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.217-221
    • /
    • 2022
  • Container system automatically controlled in its atmosphere of high CO2/low O2 was devised to contain and store pork belly meat at chilled temperature. The meat in the container system was compared in the quality preservation at 0℃ for 21 days to that in air-filled container and vacuum package. The container atmosphere could be controlled to be of 47~60% CO2 and 7~10% O2 through time-controlled intermittent CO2 injection. The controlled atmosphere in the developed system was effective in suppressing pH change and aerobic bacterial growth contributing to sensory quality preservation. Compared to control of air-filled container, vacuum packaging showed lower microbial growth and slower pH change on the meat but with high drip loss. The devised container system to keep high CO2 and mildly low O2 concentrations is effective in the meat quality preservation on overall, and may be extended to a variety of meat products with possible modification tuned for product requirements.

Qualitative analysis of some kinds of petroleum (thinner, gasoline, kerosene, and diesel oil) by gas chromatography (기체 크로마토그래피를 이용한 몇 가지 석유류(시너, 휘발유, 등유 및 경유)의 정성분석)

  • Hyun, Joon-Ho;Park, Jong-Heon;Kim, Sang-Soo;Choi, Jong-Moon
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • The evidence containing some kind of petroleum at the fire spot was analyzed by gas chromatography to identify a fire's sources. To extract some petroleum from fire evidence, 10.0 mL of n-hexane was added in this solution, and it was shaken for 30 minutes. To identify a kind of petroleum in fire evidence, the prepared n-hexane solution was injected and analyzed in the gas chromatograph. The chromatogram of sample was different from those of thinner and gasoline that have low boiling point, and shown different peak pattern to heating and boiler oils. But it was similar to the chromatogram of diesel oil. After small amount of diesel oil was added to the sample, the area of characteristic peaks was increased more than those of raw sample. From the results, the kind of petroleum in the fire evidence was diesel oil.

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Mercury Quantity in a Fluorescent Lamp for a Backlight of LCD-TVs (LCD-백라이트용 형광램프의 수은량)

  • Bong, Jae-Hwan;Kim, Yun-Jung;Hwang, Ha-Chung;Jin, Dong-Jun;Jeong, Jong-Mun;Kim, Jung-Hyun;Koo, Je-Huan;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.495-500
    • /
    • 2008
  • The amount of vapor mercury for the generation of glow discharge plasma has been calculated in a fine tube fluorescent lamp having a mixed gas of Ne+Ar including a mercury. When the ionization of atom is considered by the collision between neutral atoms (Ne, Ar, Hg) and electrons of energy $kT_e{\sim}1\;eV$, the density of vapor mercury atom has been obtained as $n(Hg){\sim}3.43{\times}10^{22}m^{-3}$ for the plasma density $n_o{\sim}10^{17}m^{-3}$. In the fluorescent lamps of out diameter 4 mm used for $32{\sim}42$-inch LCD-TVs having a mixture gas of Ne(95%)+Ar(5%) with the pressure of 50 Torr, the quantity of vapor mercury for the glow discharge has been caculated as 0.02{\sim}0.08\;mg$.

Crystal Growth of $Cr:Al_2O_3$ and $Ti:Al_2O_3$ by Czochralski Technique (용액인상법에 의한 $Cr:Al_2O_3$$Ti:Al_2O_3$ 단결정 육성)

  • Yu, Yeong-Mun;Lee, Yeong-Guk;Park, Ro-Hak
    • Korean Journal of Crystallography
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 1995
  • Cr:A12O3 and Ti:A12O3 single crystals were grown by Czochralski method, and the effects of crystal growth parameters such as pulling rate, rotation rate, dopant and growth atmosphere on crystal quality were investigated. And spectroscopic properties including lasing efficiency were also measured. Single crystals, sized of 20mm in diameter and 100-135mm in length, were successfully grown from the seed of <001> direction. With the doping level of 0.5w/o Cr2O3, pulling rate 2.0mm/hr, rotation rate of 30rpm and inert atmosphere by nitrogen gas, high quality crystals of Cr:A12O3 were grown. While in case of Ti:A12O3 crystals, high quality crystals were grown under the conditions of the doping level of 0.25w/o TiO2, pulling rate of 1.5mm/hr, rotation rate of 30rpm and reducing atmosphere by hydrogen - nitrogen mixed gas. It was confirmed that Cr3+ ion which maintains its ionoc valence during growth easily de-bubbled than Ti4+ ion which changes its valence, Fe3+ ion also has do-bubbling effect to Ti:A12O3 crystal and the reducing atmosphere by 90% N2 - 10% H2 mixed gas gave effective result on the changing of Ti4+ to Ti3+ and de-bubbling. As a result of spectroscopic measurements of Cr:A12O3 crystal, 4A2 →4F2 and 4F1 absorption transitions and E →4A2(R1) and 2A →4A2(R2) fluorenscence transitions were confirmed. And it was measured that wavelengths of laser R1 and R2 transitions were 696±5nm and 692±5nm respectively, line width of these transitions were 12A, and life-time of fluorenscence was 152μsec. In case of Ti:A12O3 crystals, it was confirmed that absortion transition of 4T2→4E and fluorescence transition of 4E→4T2 with wide range of 650-1050nm was occured. And 147μsec of life-time of fluorescence, 125.4 of figure of merit and 9% of laser efficience were also measured.

  • PDF