• Title/Summary/Keyword: 기준병실

Search Result 27, Processing Time 0.023 seconds

Radioactive Iodine Therapy Room a Part University Hospital of the Actual Conditions of Safety Management Consideration (일부 대학병원 방사성옥소 치료병실의 안전관리로 본 실태 고찰)

  • Han, Sang-Hyun;Lee, Sang-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.373-381
    • /
    • 2012
  • Using Radioiodine therapy of thyroid cancer in the past have been used for decades as many look forward to continuing treatment be used, and the current outlook of in korea 2010 based on the number of Iodine therapy room is operated by 124, but still is lacking. So many hospitals opened their therapy room, but importantly, increasing number of treatment rather than therapy room current treatment is that it must be preceded by the proper administration of the. Therefore therapy room expansion, discussions about before now being applied therapy room safety management standards, and a part university hospital based safety management standards by examining how well kept and that the therapy room to the use of the overall safety management research on the actual condition were discussed.

A Study on the Planning of the Four-bed room Unit in Public Hospitals (공공병원 4인병실 유니트의 건축계획에 관한 연구)

  • Chai, Choul Gyun;Choi, Kwangseok;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.3
    • /
    • pp.41-52
    • /
    • 2013
  • Purpose: This paper tries to set up the design guidelines for the 4 bedroom in Public Hospital wards as the standard multi-bed room in order to upgrade the bedroom environment, increase inpatients' and nurses' satisfaction level, and decrease cross infection possibility. Methods: Literature survey containing legal standards related to hospital bedrooms in Korea, Japan and Germany have been conducted. Questionnaires have been distributed to inpatients and nurses in 39 Public Hospital, and face to face talk with ward nurses in 9 Public Hospitals have been conducted. Thereafter 10 architectural drawings, 28 questionnaires from nurses and 544 questionnaires from inpatients have been analysed. Results: This article suggests some design guidelines and example drawings of standard 4 bedroom unit in Public Hospital. Implications: The result of this research would be useful as a reference when the architect tries to design a Four-bed room unit in Hospitals.

Evaluation of Stability using Monte Carlo Simulation in 2 People Isolation Treatment Room of Radiation Iodine (몬테카를로 모의 모사를 이용한 방사성옥소 2인 치료병실의 안전성 평가)

  • Jang, Dong-Gun;Ko, Sung-Jin;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.385-390
    • /
    • 2016
  • Radioactive iodine treatment that uses the 2 people isolation room is to cause unnecessary radiation exposure between patients. This research is to be tested safety of 2 people Isolation treatment room and dose-rate through conservative perspective except physiology characteristic and biology information on the assumption that patient have iodine without excretion in 2 people isolation treatment room. This research shows that 364 keV gamma rays emitted by the radioiodine was to determine that the air layer about 30 cm or lead shield 3 mm a half-layer. In addition, In addition, patients in the distance, and lead shielding, length of hospital stay (48 hours) for external radiation exposure that is received from the other patients, two of treatment as appears to be lower than the legal isolation standard dose less than 5 mSv isolation room effective analyzed that manageable.

A Study on the User-centered Patients' Room Planning Criteria - Focused on the Analysis of the Planning Criteria in Korea, Japan, Germany, U.S., and Australia - (사용자 중심 일반병실계획 기준에 관한 연구 - 국내외 관련 기준의 비교 분석 -)

  • Shin, Eun-Gyeong;Park, Soo-Been
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.4
    • /
    • pp.135-142
    • /
    • 2015
  • The goals of healthcare design based on the human rights to manage physically, psychologically, and emotionally healthy life. The healthcare designs, however, have been criticized not to reflect their primary users, patients' and families' needs, under the management strategy centered by the functional efficiency. The study focused on the patients' room design on the users' perspective. The design criteria for the patients' room in Japan, Germany, Australia, U.S. and Korea were examined and compared. The subjects of analysis are the floor plans of general hospital recently planned and built in Korea and Japan and the standard floor plan models proposed by prior studies in Korea and AusHFG in Australia. Results and conclusions are as follows: (1) the patients' room has developed as a place where the users manage their living during inpatient period and has become a private room. (2) The guidelines for patients' room size in Korea and Japan are not enough considering the users' diverse activities compare to those in U.S. and Australia. (3) The guidelines of Korea should be reconsidered for the users' comfortable lives. It must include the specific criteria of the enough space between beds, the storages, and other assistant tools and facilities. (4) The desirable types of patients' rooms by the numbers of users in Korea are proposed as a one-bed room type and a four-bed room type.

Maximum Value Calculation of High Dose Radioiodine Therapy Room (고용량 방사성옥소 치료 병실의 최대치 산출)

  • Lee, Kyung-Jae;Cho, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • Purpose: According to increment of thyroid cancer recently, patients of high dose radioiodine therapy were accumulated. Taking into consideration the acceptance capability in the current facility, this study is to calculate the maximum value of high dose radioiodine therapy in patients for treatment. Materials and Methods: The amount and radioactivity of waste water discharged from high dose radioiodine therapy in patients admitted at present hospital as well as the radiation density of the air released into the atmosphere from the high dose radioiodine therapy ward were measured. When the calculated waste water's radiation and its density in the released air satisfies the standard (management standard for discharge into water supply 30 Bq/L, management standard for release into air 3 $Bq/m^3$) set by the Ministry of Education, Science and Technology, the maximum value of treatable high dose radioiodine therapy in patients was calculated. Results: When we calculated in a conservative view, the average density of radiation of waste water discharged from treating high dose radioiodine therapy one patient was 8 MBq/L and after 117 days of diminution in the water-purifier tank, it was 29.5 Bq/L. Also, the average density of radiation of waste water discharged from treating high dose radioiodine therapy two patients was 16 MBq/L and after 70 days of diminution in the water-purifier tank, it was 29.7 Bq/L. Under the same conditions, the density of radiation released into air through RI Ventilation Filter from the radioiodine therapy ward was 0.38 $Bq/m^3$. Conclusion: The maximum value of high dose radioiodine therapy in patients that can be treated within the acceptance capability was calculated and applied to the current facility, and if double rooms are managed by improving the ward structure, it would be possible to reduce the accumulated treatment waiting period for radioiodine therapy in patients.

  • PDF

A Study on the Architectural Planning for Establishing Minimum Requirements of Ward in Korean General Hospital (우리나라 종합병원 병동부의 최소기준 설정을 위한 건축계획적 연구)

  • Kwon, Oh-Young;Yang, Nae-Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.4 no.7
    • /
    • pp.67-74
    • /
    • 1998
  • Although Medical Care System pays medical fee for each patients with the establishment of National Medicare System, patients cannot be equally benefited from hospitals. At present, the Korean government provides minimum requirements on medical facilities in enforcement of medical law, but it is not enough to guarantee the rights of patients. The purpose of this study is in search for the way to improve the minimum requirements of ward which will be needed to examine the present situation of general hospitals, to find out their problems, and to compare the law of medical facilities in korea.

  • PDF

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

Improvement of Hospital Sickroom Thermal Environment through Reestablishment of Fiducial Temperature (종합병원 온도기준 재정립을 통한 병실 열환경 개선에 관한 연구)

  • Lee, Kang-Bok;Kim, Young-Il;Chung, Kwang-Seop
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.573-578
    • /
    • 2009
  • Survey shows that temperature accounts for 90.6% of dissatisfaction in general hospital environment. In order to improve this situation, operation and thermal data of S hospital collected in 2006 are analyzed. The objective of this study is to find optimum fiducial temperature that minimizes occupants' complaints using 6 sigma method.

  • PDF

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF