Abstract

Purpose: According to increment of thyroid cancer recently, patients of high dose radioiodine therapy were accumulated. Taking into consideration the acceptance capability in the current facility, this study is to calculate the maximum value of high dose radioiodine therapy in patients for treatment. Materials and Methods: The amount and radioactivity of waste water discharged from high dose radioiodine therapy in patients admitted at present hospital as well as the radiation density of the air released into the atmosphere from the high dose radioiodine therapy ward were measured. When the calculated waste water's radiation and its density in the released air satisfies the standard (management standard for discharge into water supply 30 Bq/L, management standard for release into air 3 $Bq/m^3$) set by the Ministry of Education, Science and Technology, the maximum value of treatable high dose radioiodine therapy in patients was calculated. Results: When we calculated in a conservative view, the average density of radiation of waste water discharged from treating high dose radioiodine therapy one patient was 8 MBq/L and after 117 days of diminution in the water-purifier tank, it was 29.5 Bq/L. Also, the average density of radiation of waste water discharged from treating high dose radioiodine therapy two patients was 16 MBq/L and after 70 days of diminution in the water-purifier tank, it was 29.7 Bq/L. Under the same conditions, the density of radiation released into air through RI Ventilation Filter from the radioiodine therapy ward was 0.38 $Bq/m^3$. Conclusion: The maximum value of high dose radioiodine therapy in patients that can be treated within the acceptance capability was calculated and applied to the current facility, and if double rooms are managed by improving the ward structure, it would be possible to reduce the accumulated treatment waiting period for radioiodine therapy in patients.

갑상선암 환자가 증가함에 따라 고용량 방사성옥소 치료환자 또한 적체되고 있는 추세이다. 따라서 현재 시설의 수용 능력을 고려하여 치료할 수 있는 병실의 최대치를 산출해 보고자 한다. 본원에 입원하는 고용량 방사성옥소 치료 환자의 방출 오 폐수량과 오 폐수의 방사능을 측정하고 고용량 방사성옥소 치료 병실에서 대기 중으로 방출하는 공기 중의 방사능 농도를 측정한다. 측정된 오 폐수의 방사능과 방출하는 공기 중의 농도가 교육과학기술부에서 고시하는 기준인 배수 중의 배출 관리 기준 30 Bq/L 및 배기 중의 배출관리기준 3 $Bq/m^3$을 만족할 때 치료 가능한 병실의 최대치를 계산한다. 가장 보수적인 수치로 계산하여 환자 1명을 치료할 경우 배출되는 오 폐수의 평균 방사능의 농도는 8 MBq/L였으며, 정화조에서 117일의 감쇠 시간을 거친 후의 평균 방사능의 농도는 29.5 Bq/L였다. 환자 2명을 치료할 경우 배출되는 오 폐수의 평균 방사능의 농도는 16 MBq/L였으며, 정화조에서 70일의 감쇠 시간을 거친 후의 평균 방사능의 농도는 29.7 Bq/L였다. 또한 같은 조건일 경우 치료 병실에서 RI 배기 filter를 통과하여 방출된 공기 중의 방사능 농도는 0.38 $Bq/m^3$였다. 수용 능력을 고려하여 치료할 수 있는 고용량 방사성옥소 치료 병실의 최대치를 산출하여 현재의 시설에 적용하고 병실 내 구조개선 등으로 2인실로 운영한다면 적체되어 있는 환자의 치료 대기 기간을 단축할 수 있으리라 사료된다.

Keywords