• Title/Summary/Keyword: 기준병실

Search Result 27, Processing Time 0.022 seconds

A Study on Ways to Optimize the Period of Hospitalization During High-Dose $^{131}I$ Treatment of the Thyroid Cancer (갑상선암의 고용량 $^{131}I$ 치료 시 입원기간의 최적화방안 연구)

  • Baek, Seong-Min;Ko, Seong-Jin;Kim, Chang-Soo;Kim, Jung-Hoon;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.269-276
    • /
    • 2010
  • This study attempts to propose ways to optimize and improve the period of hospitalization for the radioiodine treatment by calculating the dose rate of patients treated with high-dose radioiodine by distance and time slot. As a result, 24 hours after the patient was treated with 100 mCi high-dose iodine, the dose rate was attenuated to $1,035{\mu}Sv/hr$ at the navel, to $109{\mu}Sv/hr$ at 50 cm, and to $33{\mu}Sv/hr$ at 100 cm. 24 hours after the patient was treated with 150 mCi high-dose iodine, the dose rate was attenuated to $637{\mu}Sv/hr$ at the navel, to $100{\mu}Sv/hr$ at 50 cm, and to $40{\mu}Sv/hr$ at 100 cm. 24 hours after the patient was treated with 180 mCi high-dose iodine, the dose rate was attenuated to $1,251{\mu}Sv/hr$ at the navel, $140{\mu}Sv/hr$ at 50 cm, and to $56{\mu}Sv/hr$ at 100 cm. In light of the current criterion for discharge recommended by the US Nuclear Regulatory Commission being $70.4{\mu}Sv/hr$, the present study indicates earlier discharge is feasible by applying a new scheme. This suggests that the proposed scheme in this study will help to solve the problem of shortage of treatment beds with the increasing trend of patients with thyroid cancer taken into consideration.

A Study on the Shielding of Iodine 131 Using Monte Carlo Simulation (몬테칼로 모사를 이용한 방사성옥소 I-131의 차폐체에 대한 효용성 연구)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Kim, Jung-Ki;Lee, Sang-Ho;Choi, Hyung-Seok;Bae, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.143-150
    • /
    • 2014
  • This study was designated to investigate the bremsstrahlung and radiation dose by beta rays. Radiation attenuation from I-131 treatment ward was analyzed using radio protective apron. Shielding materials which is included lead or water were simulated in Monte Carlo Simulation then the spectrum on interaction was analyzed. The shielding materials were categorized according to the thickness. 0.25mm and 0.5mm thick lead and 0.1mm and 0.2mm thick water shielding materials were configured in Monte Carlo Simulation for this study. Only lead shielding method and water plus lead shielding method were carried. As a results, when 0.5mm thick lead shielding method was performed, the radiation dose was similar to the results with water plus lead shielding method. In case of using 0.25mm thick lead shielding, the shielding effect was somewhat less. However, that shielding method cause dose reduction of about 60% compare with non-shielding material.

The Status of Home-Based Hospice Care in Korea (국내 가정 호스피스 운영 실태)

  • Park, Chai-Soon;Yoon, Soojin;Jung, Yun
    • Journal of Hospice and Palliative Care
    • /
    • v.16 no.2
    • /
    • pp.98-107
    • /
    • 2013
  • Purpose: This study was conducted to investigate how home-based hospice care is provided in Korea. Methods: From July 2011 through August 2011, 29 hospice facilities that provide home-based hospice care were surveyed using a questionnaire. Items included in the questionnaire were general characteristics of the organization, staff members, service programs, difficulties. Results: Among the surveyed, hospice care was hospital-based for 11 (37.9%) facilities, hospital-independent center-based care for four (13.8%) and home-based care only for 10 (34.5%). Near half the participants were located in Seoul and Gyeonggi-do. Caregivers included nurses for 62.1% of the participants, volunteers 62.0%, pastors 44.8%, social workers 37.9%, coordinators 31.0% and doctors 31.0%. The facilities offered service programs such as family counseling (96.6%), transfer to other facilities (93.1%), psychological support (89.7%), bereavement support (86.2%), dying care (79.3%), clinical care (75.9%) and spiritual support (75.9%). The major obstacles were financial issues (24.1%), lack of trained staff (20.7%) and staff members' lack of awareness of home-based hospice care (13.8%). Conclusion: In Korea, home-based hospice care is provided by an insufficient number of facilities. Moreover, the service providers are experiencing difficulties such as lack of trained staff, insufficient financial resource and staff's lack of awareness of home-based hospice care. It is necessary to increase the number of home-based hospice care facilities with consideration of even distribution across regions and standard staffing and service programs and develop related insurance policies.

Post-exposure Prophylaxis against Varicella Zoster Virus in Hospitalized Children after Inadvertent Exposure (수두-대상포진 바이러스에 노출된 소아 환자의 예방 조치)

  • Yang, Song I;Lim, Ji Hee;Kim, Eun Jin;Park, Ji Young;Yun, Ki Wook;Lee, Hoan Jong;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.180-187
    • /
    • 2016
  • Purpose: This study described the post-exposure prophylaxis (PEP) and secondary varicella infection in children inadvertently exposed to varicella zoster virus (VZV) in the hospital. Methods: We retrospectively analyzed data from patients with VZV infection who were initially not properly isolated, as well as children exposed to VZV at the Seoul National University Children's Hospital between January 2010 and December 2015. The PEP measures were determined by the presence of immunity to VZV and immunocompromising conditions. Patient clinical information was reviewed via medical records. Results: Among 147 children hospitalized between 2010 and 2015, 13 inadvertent exposures were notified due to VZV infection. Five index children had a history of VZV vaccination. Eighty-six children were exposed in multi-occupancy rooms and 62.8% (54/86) were immune to VZV. The PEP measures administered to 27 exposed patients included varicella zoster immunoglobulin and VZV vaccination. Four children developed secondary varicella, which was linked to a single index patient, including one child who did not receive PEP and three of the 27 children who received PEP. The rates of secondary varicella and prophylaxis failure were 4.7% (4/85) and 11.1% (3/27), respectively. The secondary varicella rates were 1.9% (1/54) and 9.7% (3/31) among immunocompetent and immunocompromised children, respectively. Conclusions: Delayed diagnosis of VZV infection can lead to unexpected exposure and place susceptible children and immunocompromised patients at risk for developing varicella. The appropriateness of the current PEP strategy based on VZV immunity may require re-evaluation.

Application of Noninvasive Positive Pressure Ventilation in Patients with Respiratory Failure (호흡부전 환자에서 비침습적 양압환기법의 적용)

  • Seol, Young Mi;Park, Young Eun;Kim, Seo Rin;Lee, Jae Hyung;Lee, Su Jin;Kim, Ki Uk;Cho, Jin Hoon;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Young Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.26-33
    • /
    • 2006
  • Background: Noninvasive positive pressure ventilation(NPPV) has been increasingly used over the past decade in the management of acute or chronic respiratory failure and weaning of mechanical ventilation. We performed this clinical study to evaluate the usefulness of NPPV in patients who developed acute respiratory failure or post-extubation respiratory failure. Methods: We analysed thirty four patients(sixteen males and eighteen females, mean ages 58 years) who applied NPPV(BIPAP S/T, Respironics co., USA) for respiratory failure or weaning difficulty at medical intensive care unit(MICU), emergency room and general ward of a tertiary hospital. We evaluated the underlying causes of respiratory failure, duration of treatment, the degree of adaptation, complication and predictive parameters of successful outcome. Results: The overall success rate of NPPV was seventy-one percent. The duration of NPPV applying time, baseline blood pressure, pulse rate, respiration rate, $PaO_2$, $PaCO_2$, $SaO_2$ were not different between success group and failure group. But, the baseline pH was higher in the success group. Predictors of success were higher baseline pH, patients with underlying disease of COPD, improvement of vital sign and arterial blood gas value after NPPV application. The success rate in patients with post-extubation respiratory failure was eighty percent. There were no serious complication on applying NPPV except minor complications such as facial skin erythema, abdominal distension & dry mouth. Conclusion: NPPV may be effective treatment in patients with acute respiratory failure or post-extubation respiratory failure in selected cases.

The Effects of Intra-Abdominal Hypertension on the Prognosis of Critically Ill Patients in the Intensive Care Unit (ICU) (복강 내압 항진증이 내과계 중환자의 예후에 미치는 영향)

  • Kim, Se Joong;Seo, Jeong-Su;Son, Myeung-Hee;Kim, Soo-Youn;Jung, Ki Hwan;Kang, Eun-Hae;Lee, Sung Yong;Lee, Sang Yeub;Kim, Je-Hyeong;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Yoo, Se Hwa;Kang, Kyung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.46-53
    • /
    • 2006
  • Background: Intra-abdominal hypertension (IAH) is defined as the presence of either an intra-abdominal pressure (IAP) ${\geq}12mmHg$ or an abdominal perfusion pressure (APP = mean arterial pressure - IAP) ${\leq}60mmHg$. Abdominal compartment syndrome (ACS) is defined as the presence of an IAP ${\geq}20mmHg$ together with organ failure. The purpose of this study was to investigate the prevalence of IAH and ACS on the day of admission and the effects of these maladies on the prognosis of critically ill patients in the ICU. Methods: At the day of admission to the ICU, the IAP was recorded by measuring the intravesicular pressure via a Foley catheter. The APACHE II and III scores were checked and SAPS II was also scored during the days the patients were in the ICU. The primary end point was the prevalence of IAH and ACS at the day of admission and the correlation between them with the 28-days mortality rate. The measurement of IAP continued until the 7th day or the day when the patient was transferred to the general ward before 7th day, unless the patient died or a Foley catheter was removed before 7th day. Patients were observed until death or the 28th day. Results: A total of 111 patients were enrolled. At the day of admission, the prevalence of IAH and ACS were 47.7% and 15.3%, respectively and the mean IAP was $15.1{\pm}8.5mmHg$. The rates of IAH for the survivor and the non-survivor groups were 56.5% and 71.4%, respectively, and these were not significantly different (p=0.593). Yet the rates of ACS between these two groups were significantly different (4/62, 6.5% vs. 13/49, 26.5%; Odds Ratio = 5.24, 95% CI = 1.58-17.30, p=0.004). Conclusion: In the present study, the prevalence of IAH was 47.7% and the prevalence of ACS was 15.3% on the day of admission. ACS was associated with a poor outcome for the critically ill patients in the ICU.

Analysis of dose reduction of surrounding patients in Portable X-ray (Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구)

  • Choe, Deayeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Junghoon;Kim, Donghyun;Choe, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Nowadays, the medical system towards patients changes into the medical services. As the human rights are improved and the capitalism is enlarged, the rights and needs of patients are gradually increasing. Also, based on this change, several systems in hospitals are revised according to the convenience and needs of patients. Thus, the cases of mobile portable among examinations are getting augmented. Because the number of mobile portable examinations in patient's room, intensive care unit, operating room and recovery room increases, neighboring patients are unnecessarily exposed to radiation so that the examination is legally regulated. Hospitals have to specify that "In case that the examination is taken out of the operating room, emergency room or intensive care units, the portable medical X-ray protective blocks should be set" in accordance with the standards of radiation protective facility in diagnostic radiological system. Some keep this regulation well, but mostly they do not keep. In this study, we shielded around the Collimator where the radiation is detected and then checked the change of dose regarding that of angles in portable tube and collimator before and after shielding. Moreover, we tried to figure out the effects of shielding on dose according to the distance change between patients' beds. As a result, the neighboring areas around the collimator are affected by the shielding. After shielding, the radiation is blocked 20% more than doing nothing. When doing the portable examination, the exposure doses are increased $0^{\circ}C$, $90^{\circ}C$ and $45^{\circ}C$ in order. At the time when the angle is set, the change of doses around the collimator decline after shielding. In addition, the exposure doses related to the distance of beds are less at 1m than 0.5m. In consideration of the shielding effects, putting the beds as far as possible is the best way to block the radiation, which is close to 100%. Next thing is shielding the collimator and its effect is about 20%, and it is more or less 10% by controlling the angles. When taking the portable examination, it is better to keep the patients and guardians far enough away to reduce the exposure doses. However, in case that the bed is fixed and the patient cannot move, it is suggested to shield around the collimator. Furthermore, $90^{\circ}C$ of collimator and tube is recommended. If it is not possible, the examination should be taken at $0^{\circ}C$ and $45^{\circ}C$ is better to be disallowed. The radiation-related workers should be aware of above results, and apply them to themselves in practice. Also, it is recommended to carry out researches and try hard to figure out the ways of reducing the exposure doses and shielding the radiation effectively.