• Title/Summary/Keyword: 기존 건축물

Search Result 805, Processing Time 0.026 seconds

An Efficient High-Frequency Vibration Analysis of Floors in Building Structures (고차의 진동하중을 받는 건축물 바닥판의 효율적인 진동해석)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.35-48
    • /
    • 2006
  • The object of this study is to propose the efficient method for analyzing the building floors subjected to the loading with high frequency contents. For this purpose, the method for mesh division and the selection of master DOF for FE model of building floors with these loadings are studied. Also, it is verified that the availability of thin plate element that is used by structural engineers for the modelling of the building floor of which the span-thickness ratio is usually ten times and over. And the possibility and limit of the equivalent plate which is already studied by other researcher for the multi-layer plate are investigated. At last, proposed modelling method is examined by the example structure.

A Study on Development with Lightweight Fire Wood Door (경량화 목재 방화문 개발에 관한 연구)

  • Moon, Sung-Woong;Jeon, Jun-Pyo;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.188-191
    • /
    • 2011
  • 현대사회는 기술의 발전으로 인하여 초고층 건축물과 미적 감각을 최대한 활용한 각종 구조별, 형상별 건축물들이 등장하였다. 따라서 이에 사용되는 건축 자재들이 다양화됨에 따라 화재 발생 시 유독가스생성 및 빠른 화재 확산으로 이어질 수 있는 위험성들이 잠재되어 있다. 이러한 화재위험을 최소화하기 위하여 국내에서는 KS F 2257-1:(건축 부재의 내화 시험 방법)이 제정되어 현재까지 구조물의 화재성능을 확인하고 있다. 이에 따라 내화벽 및 방화문이 건축물에 설치되어 건축물의 하중이 크게 증가하고 있다. 따라서 본 연구에서는 기존에 활용되지 않은 소재를 활용하여 목재 방화문을 제작하였으며, 이에 따른 성능을 분석하였다. 그 결과 내화 직물원단은 13분, 글라스울은 17분의 내화성능이 있는 것으로 확인되었으며, 난연 목재로 제작된 심재의 탄화를 보강할 불연 심재를 사용하여 개발 방향을 설정해야 할 것으로 분석되었다.

  • PDF

Seismic Capacity Evaluation of Wood Structure Using Soil-Wall Test (흙벽 실험에 의한 목조 건축물의 내진성능 평가)

  • Kim, Hye-Won;Yang, Won-Jik;Oh, Sang-Hoon;Lee, Jung-Han;Park, Byung-Cheol;Yi, Waon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.409-412
    • /
    • 2010
  • 본 연구는 목조 건축물 흙벽의 수평가력실험 결과를 이용한 내진성능 평가를 목적으로 한다. 흙벽 실험시험체는 기둥과 보 결합방식에 따라 민도리, 초익공, 장여방식으로 분류되고 벽체 형태에 따라 창문, 문, 전면 벽체, 인방 부재수 등으로 계획을 하였다. 12개 흙벽 시험체의 가력결과, 전면 벽체 시험체는 변위각 1/30에서 가장 큰 강성 저하율을 보이며 중인방과 수직재가 있는 벽체는 에너지 소산능력이 가장 큰 것으로 나타났다. 기존 연구로부터 목조 건축물 항복점 평가방법을 이용하여 등가탄소성 곡선으로 나타낸 전단내력은 민도리방식이 프레임과 전면 벽체일 경우 가장 크고, 전단응력은 벽체 개구율에 따라 다르게 나타났다. 실험결과로부터 적용 대상 건축물의 X, Y방향 구조성능을 산출하고 구조내진지표와 역량스펙트럼을 이용하여 내진성능 평가를 실시한 결과, 대상 목조 건축물은 내진성이 있음으로 평가되었다.

  • PDF

Seismic Capacity Strengthened by GFS of Masonry Buildings with Earthquake Damage (지진피해를 입은 조적조 건축물의 유리섬유보강에 따른 내진성능)

  • Kwon, Ki-Hyuk;Choi, Sung-Mo;Lee, Soo-Cheul;Cho, Sang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.231-237
    • /
    • 2004
  • Most of the masonry buildings have many structural defects under an earthquake load due to the small tensile force and ductility. In the foreign countries there are many the reinforcing methods of masonry buildings, but the glass fiber sheet reinforcements must be used due to various conditions in Korea. The purpose of this paper is to estimate the seismic capacity of masonry buildings damaged by earthquake and reinforced by Glass Fiber Sheet. On the basis of test results, the maximum base shear force and deformation of the masonry building with GFS were remarkably increased. From the comparison by existing strength equations and test data, the new strength equation of reinforced masonry buildings with GFS was developed.

Selection Method of Alternatives for Considering Correlation between Component Elements in Remodeling Design Process (리모델링 설계단계에서 부위구성요소의 상관관계를 고려한 대안선정 방법)

  • Park Chan-Gil;Chun Jae-Youl
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.1 s.17
    • /
    • pp.53-61
    • /
    • 2004
  • As remodeling project is progressed in the constraint which is utilization of existing resource, the subject of remodeling and extend of construction are affected by the correlation between building element. Therefore, this research analyze the correlation between component of building element in the design phase and proposed the diagram model for correlation between building element and proposed selection method of alternative plan for optimized combination of building element in remodeling project.

Application and development of Fire Propagation Model for Fire Simulation in Building(I) - The Fire Propagation Model Ejectde from Opening Fire Plume (건축물 화재성상 시뮬레이션을 위한 연소 확대 모델 개발 및 적용사례(I) - 개구분출에 기인한 연소 확대 모델 -)

  • Kang, Seung-Goo;Hong, Hae-Ri;Kim, Dong-Eun;Kwon, Young-Jin;Shin, Yi-Chul;Ohmiya, Yoshifumi;Hayashi, Yoshihiko;Otsuki, Masato
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.67-72
    • /
    • 2011
  • 본 연구는 건축물 화재성상 시뮬레이션 개발을 위한 기초 연구 자료로서 건축물 화재시 높은 비중의 가연물과 좁은 이격거리로 인하여 화재 발생시 급격히 연소확대될 위험성이 높고, 개구분출화염이 건물 화재확산의 중요한 요인이나 이 분야에 대한 연구는 부족한 실정이며, 또한 화재성상 예측시 기존 시뮬레이션에서 화재확산의 중요한 인자인 바람의 요소가 고려되지 않았다. 이에 대하여 개구분출 실물화재실험을 통하여 유풍시 개구분출화염에 기인한 수식을 도출하였으며, 이를 기반으로 향후 기존의 바람 인자를 고려하지 않은 화재성상 예측 시뮬레이션에 적용 가능성을 모색하여 국내 실정에 맞는 화재 성상 시뮬레이션 개발 구축에 대한 기초자료로 제시한다.

  • PDF

Retrofit of Artificially Perforated Shear Wall in Existing Structure (인위적인 개구부를 가지는 전단벽의 보강)

  • Kim, Hyun-Min;Choi, Chang-Sik;Choi, Youn-Cheul;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.51-61
    • /
    • 2007
  • A series of three shear wall specimens were tested under constant axial stress and reversed cyclic lateral loading to evaluate the capacity of seismic retrofit proposed for the shear wall with the opening induced by remodeling. One specimen was tested in the as-built condition and the others were retrofitted prior to testing. The retrofit involved the use of carbon fiber sheets and steel plates (thickness ; 3mm) over the entire face of the wall. Specimens were 1/2-scale representations of a one-story wall in a Korean apartment building that was built in 1980. The test results showed that failure mechanism of specimens governed by shear fracture and the strength of specimens was varied with according to the retrofitting strategies.

Development of Room Acoustic Simulation Software Using Personal Computer (퍼스날 컴퓨터를 이용한 실내음향 해석 소프트웨어의 개발)

  • 이희원
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.3-5
    • /
    • 1993
  • 실내 음향특성의 컴퓨터 씨뮬레이션 기법은 모형실험 기법과 더불어 건축물의 음향설계 분야에서 널리 사용되는 도구이다. 본 연구에서는 건축물의 음향특성을 설계단계에 예측하기 위해 영상법에 기초한 실내음향 해석 소프트웨어를 개발하였다. 개발된 소프트웨어는 건축물의 3차원 형상모델, 벽면등 반사체의 흡음특성, 음원과 수음점의 위치 등의 데이터를 입력하면, 음선의 전파경로, 수음위치에서의 반사음 패턴, 실내 음향 특성의 평가척 (음의 명료도, 잔향시간 등)을 산출하여 출력하는 기능을 지니고 있다. 기존의 씨뮬레이션 기법이 소요 장비나 비용, 시간적 제약으로 널리 실용화되기 어려웠던 점을 고려하여 PC급에서 간편하게 활용할 수 있도록 개발하였고 음선 전차경로의 그래픽 표현, 반사음 패턴의 분석등, 건축물의 음향 설계를 위한 기능을 부여하는데 중점을 두었다.

  • PDF

건축물 에너지절약 설계기준 개정에 따른 온돌시스템 기술개발 방향

  • 강재식;이승언
    • 월간 기계설비
    • /
    • s.143
    • /
    • pp.60-74
    • /
    • 2002
  • 건축물의 에너지 이용을 효율화하기 위하여 단열기준 등을 기존보다 20% 이상 강화하는 것을 골자로 하는 건축물의 에너지절약 설계기준(건설교통부 고시 제2001-118호)이 지난해 6월 1일부터 시행되고 있다. 개정 기준의 가장 큰 특징은 단열기준의 적용 부위를 외기에 직접 면한 부위와 간접 면한 부위로 구분하고, 지역을 중부와 남부, 제주도로 구분$\cdot$설정하여 부하조건과 에너지 소비특성에 따라 건축물의 단열기준을 세분화한 것이다. 특히, 종래에는 최하층 바닥에만 적용하였던 거실 바닥(온돌)의 단열기준을 중간층까지 확대$\cdot$적용하였고, 여기에 온돌시스템의 열적 특성을 고려하여 단열기준의 적용 부위를 보다 구체적으로 설정하고 있다. 따라서 종래의 온돌시스템에서 채움층으로 일반적으로 사용하고 있는 현장 타설식 경량기포콘크리트의 열전도율이 0.13W/mK 내외임을 고려한다면 현행 습식온돌시스템의 열관류율은 $1.0W/m^{2}K$ 이상이 될 것으로 예상됨으로서 앞으로 온돌시스템의 배관층 하부에 $1.0m^{2}K/W$ 이상의 열전도저항을 지닌 단열층이 구성되어야만 개정기준에서 정하는 열관류율 $0.81W/m^{2}K$(기준층 기준)의 성능과 배관하부의 열전도저항값 적용비율을 만족할 수 있을 것으로 판단된다.

  • PDF