• Title/Summary/Keyword: 기저선

Search Result 259, Processing Time 0.033 seconds

Detection Probability Improvement of Bias Error of GPS Carrier Measurement using Baseline Constraint (기저선 제한조건을 이용한 GPS 반송파 바이어스 오차의 검출확률 향상)

  • Lee, Eun-Sung;Chun, Se-Bum;Lee, Young-Jea;Kang, Tea-Sam;Jee, Gyu-In
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.9
    • /
    • pp.88-93
    • /
    • 2004
  • A method is suggested for validating the existence of bias error on GPS carrier measurement. The baseline constraint is used as an addition measurement, which augments the original measurement equation. The detection probability is calculated on both cases. The first case is using GPS carrier measurement only, the second case is using GPS carrier and a baseline constraint. The improvement of the detection probability is shown, and the advantage of using baseline constraint is described statistically, the results of the simulation is shown and analyzed.

A Study on the Implementation of Real-time Digital Filter System for the Baseline Wandering Elimination (기저선 변동 제거를 위한 실시간 디지털 필터 시스템 구현에 관한 연구)

  • 윤승구;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.512-515
    • /
    • 2001
  • The heifer electrocardiograph is a widely progressing research which is used in judgement to existence for a heart disease and analyzes electric potential changes of heart movement during continuous living of everyday after attaching to body portable holler recorder for twenty-four hours. In order to obtain electrocardiogram clearly, it must eliminate that 60Hz power line interference, baseline wandering, noise of muscle constriction. In holter electrocardiogram, the most big problem which is recorded signal of ECG(electrocardiogram) is a baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such baseline is roughly irregular wandering and shaking up and down therefore the part of baseline wandering elimination is very important because it is difficult of ECG diagnosis. In this study, it is stabilized baseline wandering in analog part as implementation f real-time signal processing digital filter so it is applicable to analyze patient's heart disease by way of design of baseline wandering elimination system.

  • PDF

Minimizing Algorithm of Baseline Wander for ECG Signal using Morphology-pair (Morphology-pair를 이용한 심전도 신호의 기저선 변동 잡음 제거 알고리즘)

  • Kim, Sung-Wan;Kim, Se-Yun;Kim, Tae-Hun;Choi, Byung-Jae;Park, Kil-Houm
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.4
    • /
    • pp.574-579
    • /
    • 2010
  • The baseline wander is most fatal noise, because it obstructs reliable diagnosis of cardiac disorder. Thus, in this paper, the morphology-pair is proposed for estimation of baseline wander except P, T-wave and QRS-complex. Proposed Morphology-pair is able to except P, R, T-wave which have characteristics of local maxima. Likewise Q, S-wave such as local minima are excepted by proposed Morphology-pair. The final baseline wander eliminated ECG signal is deducted by subtraction of original ECG and estimated baseline wander. The experimental results based on the MIT/BIH database show that the proposed algorithms produce promising results.

ECG Baseline Wandering Removing Algorithm using Slope analysis and Curve Point Detection (기울기 분석과 굴곡점 검출을 이용한 ECG 기저선 잡음 제거 알고리즘)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2105-2112
    • /
    • 2010
  • The noise component of electrocardiogram is not distributed in a certain frequency band. It is expressed in various types of signals by rater's physical and environmental conditions. Particularly, since the baseline wander is occurred by the mixture of the original signal and 0 ~ 2 [Hz] range of the frequency components according to muscle constraction of part attaching to an electrode and respiration rythm, it makes the ECG signal analysis difficult. Several methods have been proposed to eliminate the wandering effectually. However, they have some problems. In some methods, the high processing time is required due to the computational complexity, while in other cases ECG signal morphology can be distorted. This paper suggests a simple and effective algorithm that eliminates baseline wander with low computational complexity and without distorting signal morphology. First, the algorithm detects and segments a baseline wandering interval using slope analysis and curve point detection, second, approximates the wandering in the interval as a sinusoid, and then subtracts the sinusoid from signal. Finally, ecg signals without baseline wander are obtained. In order to evaluate the performance of the algorithm, several ECG signals with baseline wandering in MIT/BIH ECG database 101, 111, 113, 234 record were chosen and applied to the algorithm. It is found that the algorithm removes baseline wanders effectively without significant morphological distortion.

An Implementation Of Digital Signal Processing System For The Baseline Elimination (베이스라인 제거를 위한 디지털 신호처리 시스템 구현)

  • 윤승구;박형재;박종억;배의환;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.7
    • /
    • pp.1287-1294
    • /
    • 2001
  • As size of waveform is very small, ECG(electrocardiogram) signal is difficult to analyze for noise which is occurred when it measures. In order to obtain ECG clearly, it must eliminate that power line interference, baseline wandering, noise of muscle constriction. In ECG, the worst problem which is recorded signal of ECG is the baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such the baseline is roughly irregular wandering and shaking up and down therefore the part of the baseline wandering elimination is very important because it is difficulty of ECG diagnosis. In this study, as implementation of real-time signal processing digital filter it is applicable to analyze patient's heart disease by way of design of the baseline wandering elimination system.

  • PDF

A study on eliminating baseline wander of ECG using approximated S-wave contour (근사 S-파 궤적을 이용한 심전도의 기저선 변동 제거에 관한 연구)

  • Ju, Jangkyu;Lee, Ki Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.33-38
    • /
    • 2008
  • The baseline wander of ECG makes difficult to detect P-, Q-, R- and S-wave. This paper presents and compares two method to remove the baseline wander of ECG using slope traceing waves. For the first method that had been proposed already[1], the ascending slope tracing method is used to eliminate baseline wander. And the second method employs the contour of the approximated S-wave to remove baseline wander. These two methods are common to use the slope tracing wave. However, the first one is to get difference signals between the ascending tracing waves and ECG signals, and the other is to remove baseline wander using the contour of the approximated S-wave obtained from descending slope waves. To evaluate these methods, we apply to MIT/BIH database.

  • PDF

A Baseline Elimination Method for ECG using Wavelet Transform (웨이브렛 변환을 이용한 심전도의 기저선 제거)

  • 최형민;김원식;정광일;황재호
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.05a
    • /
    • pp.128-133
    • /
    • 2003
  • 본 연구에서는 심전도 신호의 전처리 과정에서 원신호의 왜곡을 최소화하여 기저선을 제거 할 수 있는 웨이브렛 모함수를 결정하기 위하여, European S-T T database의 심전도 신호에 다양한 웨이브렛 모함수를 적용하여 기저선을 제거하였으며 제거효율을 평가하기 위하여 SNR과 RSE를 계산하였다. 실험결과 가장 우수했던 웨이브렛 모함수는 db8(diff: 27.12), coif5(diff: 25.32), sym7(diff: 25.13)이었으며, diff(meanSNR-meanRSE)의 값이 23미만으로는 심전도의 진단 파라미터까지 왜곡시키므로 사용할 수 없다는 것을 알 수 있었다.

  • PDF

Removing Baseline Drift in ECG Signal using Morphology-pair Operation and median value (Morphology-pair 연산과 중간 값을 이용한 심전도 신호의 기저선 변동 잡음 제거)

  • Park, Kil-Houm;Kim, Jeong-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.107-117
    • /
    • 2014
  • This paper proposed the method of removing baseline drift by eliminating local maxima such as P, R, T-wave signal region and local minima Q, S-wave signal region. We applied morphology-pair operations improved from morphology operation to the ECG signal. To eliminate overshoot in the result of morphology-pair operation, we apply median value operation to the result of morphology-pair operation. We use MIT/BIH database to estimate the proposed algorithm. Experiment result show that proposed algorithm removing baseline drift effectively without orignal ECG signal distortion.

Removing Baseline Drift from ECG Signal Using Smoothing Spline and Morphology Operation (평활화 스플라인 연산과 형태학 연산을 이용한 기저선 변동 잡음 제거)

  • Back, Seung-Gwan;Choi, Chang-Hoon;Kim, Jeong-Hong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.162-171
    • /
    • 2017
  • Low frequency noise components causes the baseline drift in the ECG signals. In this paper, a morphological operation and smoothing spline technique are used for ECG signal processing in order to accomplish baseline correction. Removing the baseline drift from ECG signal using morphology operation, the feature of original signal may be distorted. To resolve this distortion problem, we applied a smoothing spline operation after morphology operation. In order to compare with existing morphology operation method for baseline correction, we apply proposed method to ECG data in MIT/BIH database. Compared to other existing method, our proposed method achieved low data distortion on the original signal.

(A Design of Adaptive Neural Network Filter to Remove the Baseline Wander of ECG) (심전도 신호의 기저선 잡음 제거를 위한 적응 신경망 필터 설계)

  • Lee, Geon-Gi;Kim, Yeong-Il;Lee, Ju-Won;Jo, Won-Rae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.1
    • /
    • pp.76-84
    • /
    • 2002
  • In this paper, it is studied to remove the baseline wander and to minimize the distortion of ST segment in the noise filtering of ECG. In general, the standard filter and adaptive filter are used to remove the baseline wander of the ECG. But the standard filter is limited because the frequency of the baseline signal is variable and the apative filter is difficult to select the reference signal in case of using the adaptive filter. So we proposed a new method of the structure without reference signal using neural networks. To be convinced of the performance of this method, we used ECG data of MIT-BIHs. and obtained the result of the high performance,(-53.3[dB]) than standard filter(-16.3[dB]) and adaptive filter (-44.9[dB]).