• Title/Summary/Keyword: 기온저감

Search Result 123, Processing Time 0.029 seconds

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Effects of Soil Organic Matter Contents, Paddy Types and Agricultural Climatic Zone on CH4 Emissions from Rice Paddy Field (벼 논에서 토양 유기물 함량, 논 유형 및 농업기후대가 CH4 배출에 미치는 영향)

  • Ko, Jee-Yeon;Lee, Jae-Saeng;Woo, Koan-Sik;Song, Seok-Bo;Kang, Jong-Rae;Seo, Myung-Chul;Kwak, Do-Yeon;Oh, Byeong-Gun;Nam, Min-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.887-894
    • /
    • 2011
  • To evaluate the effects of abiotic factors of paddy fields on greenhouse gases (GHGs) emissions from rice paddy fields, $CH_4$ emission amounts were investigated from rice paddy fields by different soil organic matter contents, paddy types, and agricultural climatic zone in Yeongnam area during 3 years. $CH_4$ emission amounts according to soil organic matter contents in paddy field were conducted at having different contents of 5 soil organic matters fields (23.6, 28.7, 31.0, 34.5, and $38.0g\;kg^{-1}$), The highest $CH_4$ emission amount was recorded in the highest soil organic matters plot of $38.0g\;kg^{-1}$. High correlation coefficient (r=$0.963^{**}$) was obtained between $CH_4$ emissions from paddy fields and their soil organic matter contents. According to paddy field types, $CH_4$ emission amounts were investigated at 4 different paddy fields as wet paddy, sandy paddy, immature paddy, and mature paddy. The highest $CH_4$ emissions was recorded in wet paddy (100%) and followed as immature paddy 64.0%, mature paddy 46.8%, and sandy paddy 23.8%, respectively. For the effects of temperature on $CH_4$ emissions from paddy fields, 4 agricultural climatic zones were investigated, which were Yeongnam inland zone (YIZ), eastern coast of central zone (ECZ), plain area of Yeongnam inland mountainous zone (PMZ), and mountainous area of Yeongnam inland mountainous zone (MMZ). The order of $CH_4$ emission amounts from paddy fields by agricultural climatic zone were YIZ (100%) > ECZ (94.6%) > PMZ (91.6%) > MMZ (78.9%). The regression equation between $CH_4$ emission amounts from paddy fields and average air temperature of Jul. to Sep. of agricultural climatic zone was y = 389.7x-4,287 (x means average temperature of Jul. to Sep. of agricultural climatic zone, $R^2=0.906^*$)

Effect of the Landscape Crop, Chrysanthemum zawadskii on Reducing Soil Loss in Highland Sloping Area (경관작물 구절초의 고랭지 경사지 밭 토양유실 경감 효과)

  • Kim, Su Jeong;Sohn, Hwang Bae;Hong, Su Young;Kim, Tae Young;Lee, Jung Tae;Nam, Jung Hwan;Chang, Dong Chil;Suh, Jong Taek;Kim, Yul Ho
    • Korean Journal of Plant Resources
    • /
    • v.33 no.1
    • /
    • pp.15-23
    • /
    • 2020
  • There is high vulnerability of soil loss in sloping and highland used for agricultural production due to the low surface covering in summer rainy season. This study evaluated the surface-covering rate of landscape crop in reducing soil loss in the highland. The experiment was conducted in a 55% sloped lysimeter with three treatments of planting density using Korean native chrysanthemum, and investigated the soil coverage rate, run-off water, and soil erosion. The three treatments according to the degree of soil covering are bare soil as the control treatment TC, coverage rate of 43-59% for treatment T1, and, coverage rate of 63-81% for treatment T1, and T2. During the cultivation period, the average reduction of run-off water was 71% for treatment T1 and 76% for treatment T2, which are better, compared with the control. The reduction in eroded soil was 84% in treatment T1 and 98% for treatment T2, which is also better than the control treatment. Therefore, it is possible to alleviate the soil loss in sloping lands by planting chrysanthemum, which is superior among the perennial plant species and considered as a crop with economic value.

Air Temperature Modification of an Urban Neighborhood Park in Summer - Hyowon Park, Suwon-si, Gyeonggi-do- (여름철 도시근린공원의 기온저감 효과 - 경기도 수원시 효원공원 -)

  • Park, Sookuk;Jo, Sangman;Hyun, Cheolji;Kong, Hak-Yang;Kim, Seunghyun;Shin, Youngkyu
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1057-1072
    • /
    • 2017
  • In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small ($0.2-0.5^{\circ}C$). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was $0.5-0.8^{\circ}C$ (Max. $1.6-2.1^{\circ}C$). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of $0.9-1.7^{\circ}C$. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of $1.5^{\circ}C$ lower temperature in the daytime and $0.7^{\circ}C$ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was $0.8-1.0^{\circ}C$, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean $0.9-1.3^{\circ}C$ (Max. $2.0-3.9^{\circ}C$) lower in the daytime than for the residential and apartment locations and mean $0.4-1.0^{\circ}C$ (Max. $1.3-3.1^{\circ}C$) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean $1.0-1.6^{\circ}C$ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.

A Study on Greenspace Planning Strategies for Thermal Comfort and Energy Savings (열쾌적성과 에너지절약을 위한 녹지계획 전략 연구)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.3
    • /
    • pp.23-32
    • /
    • 2010
  • The purpose of this study is to quantify human energy budgets for different structures of outdoor spatial surfaces affecting thermal comfort, to analyze the impacts of tree shading on building energy savings, and to suggest desirable strategies of urban greenspace planning concerned. Concrete paving and grass spaces without tree shading and compacted-sand spaces with tree shading were selected to reflect archetypal compositional types for outdoor spatial materials. The study then estimated human energy budgets in static activity for the 3 space types. Major determinants of energy budgets were the presence of shading and also the albedo and temperature of base surfaces. The energy budgets for concrete paving and grass spaces without tree shading were $284\;W/m^2$ and $226\;W/m^2$, respectively, and these space types were considerably poor in thermal comfort. Therefore, it is desirable to construct outdoor resting spaces with evapotranspirational shade trees and natural materials for the base plane. Building energy savings from tree shading for the case of Daegu in the southern region were quantified using computer modeling programs and compared with a previous study for Chuncheon in the middle region. Shade trees planted to the west of a building were most effective for annual savings of heating and cooling energy. Plantings of shade trees in the south should be avoided, because they increased heating energy use with cooling energy savings low in both climate regions. A large shade tree in the west and east saved cooling energy by 1~2% across building types and regions. Based on previous studies and these results, some strategies including indicators for urban greenspace planning were suggested to improve thermal comfort of outdoor spaces and to save energy use in indoor spaces. These included thermal comfort in construction materials for outdoor spaces, building energy savings through shading, evapotranspiration and windspeed mitigation by greenspaces, and greenspace areas and volume for air-temperature reductions. In addition, this study explored the application of the strategies to greenspace-related regulations to ensure their effectiveness.

태양광 고효율 저가화 기술동향

  • Gil, Jong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.85-85
    • /
    • 2015
  • 현재 태양광에너지 시장은 해마다 빠른 속도로 성장하는 추세이며 50 GWp/년 이상의 시장으로 변화하였고 앞으로도 전체적인 성장세는 지속 유지될 것으로 판단된다. 하지만 이와 아울러 각 Value chain 별로 많은 기업들이 생겨나게되어 각각의 기업들이 제품을 고효율 저가화 함으로서 경쟁력을 확보하기 위해 많은 노력들이 기울이고 있으며 본 강연에서는 이러한 측면에서 태양광 에너지의 분야별 고효율/저가화를 위한 기술동향을 살펴보고자 한다. 태양광 산업은 아직은 다소 높은 발전단가로 인해 일부 정부의 지원이나 정책에 의해 산업의 규모가 결정되게 되는데 주요한 지원제도는 RPS 제도와 FIT 제도가 있으며 우리나라는 초기 FIT 제도로 국가에서 태양광에서 생산된 전기를 높은 가격에 사주었으나 근래에들어 RPS 제도를 운영하게 되었으며 매전을 하면서 SMP에 준하는 수익을 창출하고 이와 아울러 REC 를 확보하여 확보된 REC 단가에 의해 추가적인 수익을 창출하는 구조의 발전사업이 진행되고 있다. 그리고 RPS나 FIT와 같은 정부의 지원없이도 발전단가의 경쟁력을 확보하는 시점을 그리드패러티라고 하며 이는 매우 중요한 의미를 갖는다. 태양광의 저가화는 그리드패러티 달성을 확보하기 위해 필수적으로 필요한 사안이며 앞으로도 이러한 저가화 / 고효율화 기술노력은 계속 진행될 것으로 판단된다. 우선 소재의 가격을 줄이기 위해 웨이퍼의 두께가 점점 박형화 되어가고 박형화 되면서도 안정적인 공정수율 및 효율을 향상시키기 위한 기술개발이 진행되고 있으며 Cell 분야에 있어서도 고효율을 위한 다양한 Texturing 기술 및 패시베이션 기술의 개발이 이루어 지고 있으며 고효율 컨셉의 MRT cell, Back contact cell 등 고효율 구조의 cell의 양산을 진행하고 있는 등 최근 n-type 기반의 고효율 cell 기술이 활발하게 양산화 검토가 이루어 지고 있다. 모듈 분야에 있어서는 저가/고효율화와 아울러 제품의 신뢰성 확보가 무엇보다도 중요하게 다루어 지고 있으며 이는 모듈이 최소 25년 이상 Field 에서 운용되어 수익창출이 가능해야 하므로 가장 중요한 요소중에 하나라고 할 수 있다. 신뢰성 측면에서 중요하게 다루어 지고 있는 것 중 하나가 PID 저감을 위한 노력이며 이와 관련된 각 소재의 개발이 가장 활발하게 진행되고 있으며 이와 아울러 장수명을 보장하기 위한 내구성이 겸비된 봉지재의 개발 또한 많은 관심을 불러 일으키고 있다. 저가/고효율화를 위해 CTM loss를 줄이기 위한 다양한 시도가 이루어지고 있으며 특수 형태의 리본으로 빛의 흡수를 증가시키거나 컨택저항을 최소화 하기위한 소재의 개발이 이루어 지고 있다. 태양광 시스템 분야의 경우 발전량과 수익창출에 있어 직접적인 영향을 미치는 분야로서 전체 시스템의 loss 를 줄이고 최적의 환경에서 최대한의 발전량을 확보하기 위한 array 설계 및 운용기술이 활발하게 개발되고 있으며 시스템에서의 loss를 줄여줄수 있는 마이크로 인버터나 multi string 인버터의 적용도 이루어 지고 있으나 저가화를 위한 추가적인 노력이 필요한 상황이다. 본 강연의 마지막으로 이러한 노력들의 산물인 특수 태양광 제품 및 시스템의 기술동향에 대해 살펴하고자 한다. 사막은 전체면적의 1/3을 차지할 정도로 넓은 면적을 자랑하지만 밤과 낮의 기온차 그리고 계통 선로의 부재 등 적용하기 어려운 환경적인 제약도 함께 존재하며 이러한 문제를 해결하기 위한 방안에 대해 살펴보고 최근 Hot issue 중의 하나인 수상 태양광 시스템의 장, 단점과 기술적 특성 등을 살펴보고자 한다.

  • PDF

An Integrated Assessment of Green Environment on Urban Space (도시공간의 통합적 녹지환경 평가)

  • Lee, Woo-Sung;Jung, Sung-Gwan;Park, Kyung-Hun;You, Ju-Han
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.2
    • /
    • pp.15-31
    • /
    • 2014
  • The purpose of this study is to assess the green environment on urban space and to suggest the sustainable green space planning. The study area is Dalseo-gu which has the biggest spatial imbalance of green space among 7 districts of Daegu. Three functions such as nature-ecological, environment-control, and usage function were established for assessing the green environment. For the assessment step of nature-ecological function, 'green connectivity' and 'animal movement' were used. Also,'thermal environment' and 'temperature decrease' were utilized in terms of environment-control function and 'green space's service supply' were utilized in terms of usage function. According to the results of integrated assessment, the green rich zone(Grade I) was 44.8% of total area in Dalseo and this zone was distributed along the southern forest of Mt. Ap and Mt. Biseul and the northern forest of Mt. Gung and Mt. Waryong. On the other hand, the green broken zone(Grade IV) was located in the residential areas of Gamsam and Jukjeon and the residential and industrial areas of Wolseong 1 and Jincheon and this zone was 5.5% of total area. The findings from this study can be used as the plan criteria for construction and distribution of green space in urban master plan.

Estimation of Quantitative Daily Precipitation Forecasting for Integrated Real-time Basin Water Management System (실시간 물관리를 위한 정량적 강수예측기법에 관한 연구)

  • Oh, Jai-Ho;Kim, Jin-Young;Kang, Bu-Sick;Jeong, Chang-Sam;Ko, Ick-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1488-1491
    • /
    • 2006
  • 본 연구에서는 실시간 통합 물관리 시스템의 일환으로 월별 일강수량 예측 시스템에 관한 연구를 실시하였다. 선행시간 2일 예측에 대해서는 기상청 생성 수치모의 RDAPS (Regional Data Assimilation and Prediction System)를 기반으로 강수진단모형인 QPM (Quantitative Precipitatiom Model)을 이용하여 지형효과를 보정하였으며, 선행시간 2일에서 8일까지의 예측에 대해서는 GDAPS (Global Data Assimilation and Prediction System) 모의결과를 QPM을 이용하여 보정하였고, 선행시간 10일 이후의 예측값은 통계적 기법을 이용한 자료를 활용하였다. 통계적 기법으로는 과거 20년간의 관측된 강수경향을 이용하여 시스템을 구축하였다. 강수진단모형 (QPM)은 Misumi et al. (2001), Bell (1978), Collier (1975)등이 제안한 바 있는 Collier-type의 모형으로서 이들 모형은 소규모 지형 효과를 고려한 강수량을 산출하는 진단 모형이다. QPM은 중규모 예측 모형으로부터 계산된 수평 바람, 고도, 기온, 강우 강도, 그리고 상대습도 등의 예측 자료를 이용하고, 중규모 예측 모형에서는 잘 표현되지 않는 소규모 지형 효과를 고려함으로써 중규모 예측 모형에서 생산된 상대적으로 성긴 격자의 강수량 예측 값을 상세 지역의 지형을 고려한 강수량 예측 값으로 재구성하게 된다. QPM은 중규모 모형으로부터 나온 자료를 초기 자료로 이용하고 3 km 간격의 상세 지형을 반영하는 모형으로 소규모 지형 효과를 표현함으로써 상세 지역에서의 강수량 산출과 지형에 따른 강수량의 분포 파악이 용이할 뿐 아니라, 계산 효율성을 개선시킬 수 있다.착능이 높은 것으로 사료되었다.X>${\mu}_{max,A}$는 최대암모니아 섭취률을 이용하여 구한 결과 $0.65d^{-1}$로 나타났다.EX>$60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주

  • PDF

A Study on the Urban Climate Mapping Method Using GIS (GIS를 이용한 도시기후지도 제작방안 연구)

  • Choi, Byoung-Gil;Cho, Tae-In;Na, Young-Woo;Lee, Kwang-Won
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.183-191
    • /
    • 2011
  • The objective of this study is 10 investigate the method to produce urban climate map so as to cope with climate change and efficiently control greenhouse gas in the city by using GIS. To produce urban climate map by using GIS, statistical data and spatial data of greenhouse gases related to climate change were collected and analyzed and the correlation between the type of urban climatop and urban climate change was analyzed by establishing GIS framework data construction method to prepare urban climate map and preparing and analyzing urban climate map related to the demonstration area. It was found that exact greenhouse gases emission quantity and absorption quantity can be calculated for each type of urban climatop by preparing urban climate map and the temperature is high in residential area, commercial area and industrial area and the emission quantity per unit area is high in the traffic area and industrial area. It seems that the influence of climate change can be presented for urban development by suggesting urban climate change for type of urban climatop and they can be utilized to save energy in urban area and to establish greenhouse gases reducing policy.

Utilization of Charcoal as an Environmentally Friendly Building Materials (II) - A Study on the Energy Saving and Sound Insulation Characteristics of Building Materials Prepared with Charcoal - (목탄을 이용한 친환경 건축자재 이용기술(II) - 목탄 함유 건축자재의 에너지 절감 및 차음 특성에 관한 연구)

  • Ahn, Byoung-Jun;Paik, Ki-Hyon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.41-52
    • /
    • 2011
  • This study was carried out to investigate the effect of energy saving and sound insulation of building materials mixed with charcoal. To investigate the functionality of building based on the difference of construction materials, three different experimental buildings were constructed. They were buildings built with the conventional construction materials (A), the charcoal construction materials (B), and the charcoal-sericite construction materials (C). The study showed that energy consumption could be reduced approximately 9.5% and 14.5% by replacing A with B and C, respectively. Especially, it is revealed that the lower outdoor temperature was, the higher energy saving effect was. Also, after shutoff the boiler switch the decrease rate of room temperature of the one using B was lower than those of others using A and C so that the room temperature at the building using B was higher by $3.5{\sim}4.2^{\circ}C$ in the 1 meter air above the ground and by $4.4{\sim}5.4^{\circ}C$ on the floor surface after 12 hours passed. In the building noise test the heavy-and light-weight impact sound of the plate, represented by criterion of noise between floors in multi-story building, tended to decrease in the test sample containing charcoal.