• Title/Summary/Keyword: 기온저감

Search Result 123, Processing Time 0.031 seconds

Effect of Rice Cultural Patterns on Methane Emission from a Korean Paddy Soil (벼 재배양식(栽培樣式)이 메탄가스 배출에 미치는 영향(影響))

  • Lee, Kyeong-Bo;Lee, Deog-Bae;Kim, Jong-Gu;Kim, Yong-Woong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.35-40
    • /
    • 1997
  • This study was conducted to investigate methane emission under different rice cultural practices in paddy soil (Jeonbug Series, occurring on fluvio-alluvial plain). The rates of application of fresh rice straw were 5,000kg/ha in combination with 110 and 160kg N/ha as chemical fertilizer. The methane emission among the rice cultural practices was in the order of transplanting cultivation, direct seeding on flooded surface and direct seeding on dry paddy field. The average methane flux was $10.27mg/m^2/h$ in direct, seeding on dry paddy field and $24.1mg/m^2/h$ in transplanting cultivation. The diurnal variation of methane emission at heading stage was high from 9 a.m. till 7 p.m. and the methane emission rate was highly correlated with air temperature fluctuation and soil Eh. The seasonal change of methane flux was high from ear formation stage to heading stage.

  • PDF

Design and Construction of Green Infrastructure-Low Impact Development Experimental Complex for Hydrological cycle (부산대학교 GI·LID 물순환 실증단지 계획 및 구축)

  • Lee, Jae-Hyuk;Yoon, Eui-Hyeok;Jang, Young-Su;Shin, Hyun-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.319-319
    • /
    • 2016
  • 최근 급격한 기후변화와 도시화로 인하여 강우량 및 강우강도는 약 20% 증가하고 강우일수는 14% 감소하며 도시 기온이 최대 $3^{\circ}C$까지 증가하는 등의 현실적인 문제가 발생하고 있다. 이로 인한 도시 물순환체계의 파괴는 도시물관리 여건의 악화로 이어지고 특히 불투수면적 증가로 인한 도시 홍수 및 침수의 증가, 잦은 도시 고온 현상, 도시하천의 건천화로 수질 악화를 야기하는 실정이다. 이에 국토의 자연자원을 보전하고 기후변화에 적응하면서 도시의 안전도와 가치를 높이기 위한 물관리 정책은 먼저 물을 순환을 보다 적극적으로 반영하고 통합적인 물관리 체계 확보를 요구한다. 이를 위해서는 발생원 관리를 포함한 소규모 분산관리 체계로 변화하여야 하며 이들 시설에 대한 네트워크화를 통해 기후변화에 강건하고 통합관리쳬계를 구축하는 것이 중요하다. 이를 위해서는 저영향개발(LID, Low Impact Development) 및 그린인프라(GI, Green Infrastructure) 기반의 분산식 빗물관리기법의 도입이 절실하다. 현재 국내에서는 제도적으로 기후변화 대비, 지속가능한 도시환경 구축을 위한 물순환 건전화를 위해 100대 국정화제에 포함시키는 등(2013.2) 도시계획 및 기반시설 설치 LID기법의 법제적 산업적 도입을 추진중에 있으나, LID 기술의 수자원 치수, 이수 및 환경 효율성에 대한 객관적인 정보의 부재, LID 기술에 대한 효율성 검증 및 인증시스템의 부재, LID 기술의 무분별한 국외기술 도입으로 인한 효과 저감, LID 기술의 설계, 시공, 관리를 위한 매뉴얼 및 가이드라인의 부재, LID 기술에 대한 지자체 지원 및 전문가 양성 시스템의 부재 등 복합적인 문제를 안고 있어 GI 및 LID 기술의 적용을 통한 새로운 도시 및 유역차원의 수자원확보와 재해경감기술 패러다임 확보가 용이하지 않다. 이를 위해 본 연구에서는 강우유출수 관리를 위한 LID기술 신뢰도 향상 및 단일화, 표준화된 효율성 검증 기술 개발과 더 나아가서 도시-건축-수자원-도로-조경 등의 종합적인 인프라를 바탕으로 LID기술 통합관리 및 기술 고도화를 위해 부산대학교 GI LID 물순환 실증단지의 계획 및 구축을 수행하였다.

  • PDF

Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface (온도 변색 도료의 지붕 적용 및 냉방효과 분석)

  • Baek, Sanghoon
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.115-123
    • /
    • 2022
  • This study aims to introduce a temperature discoloration roof system and its cooling effect in the summer. Temperature discoloration paints can reverse their colors based on temperature changes. If these paints on the roof surface could color-shift between white in the summer and black in the winter, the indoor cooling and heating loads can be affected by the changes in reflection and absorption of solar radiation. Focusing on the summer period, the study analyzed the cooling effect of applying temperature discoloration paint that color-shifts from white to black on the roof surface of a small experimental building module and compared it to commonly used gray and green roof colors. Results of the experiment showed that the surface temperature of the roof with temperature discoloration paint was lower than the gray and green color roofs by a maximum of 10℃. Furthermore, the indoor temperature of the experimental module with the temperature discoloration roof was lower than the gray and green roofs by approximately 3℃. Findings of the study indicate that the application of temperature discoloration paint to the roof can reduce indoor cooling loads.

Reduction of Shear Strength of Railway Roadbed Materials with Freezing-thawing Cycle (동결융해 반복에 따른 철도노반재료의 전단강도 변화)

  • Choi, Chan yong;Shin, Eun chul;Kang, Hyoun Hoi
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.7
    • /
    • pp.13-21
    • /
    • 2011
  • In seasonal frozen areas with climatic features, which have a temperature difference in the winter and thawing season, changes of mechanical properties of the soil in the zone could be seen between the freezing and thawing surface. In particular, in soil with many fine particles, a softening of the roadbed usually occurs from frost and thawing actions. The lower bearing capacity is a rapidly progressive the softening of roadbed, and occurred a mud-pumping by repeated loading. In this study, the three kind of sandy soil with contents of fine particles were conducted by directly shear box test with the number of cyclic in freeze-thawing and the water content of soil. Subsequently, the relationship between the shear strength and freeze-thaw cycling time was obtained. The shear strength was decreased with the increase of the freeze-thaw cycling time. A shear stress deterioration of the soil with power function modal is proposal.

Analysis of Human Thermal Environment in an Apartment Complex in Late Spring and Summer - Magok-dong, Gangseo-gu, Seoul- (아파트 단지의 늦봄·여름철 인간 열환경 분석 - 서울특별시 강서구 마곡동 -)

  • Park, Sookuk;Hyun, Cheolji;Kang, Hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.1
    • /
    • pp.68-77
    • /
    • 2022
  • The human thermal environment in an apartment complex located in Seoul was quantitatively analyzed to devise methods to modify human heat-related stresses in landscape and urban planning. Microclimatic data (air temperature, relative humidity, wind speed, and short- and long-wave radiation) were collected at 6 locations [Apt-center, roof (cement), roof (grass), ground, playground, and a tree-lined road] in the late spring and summer, and the data were used to estimate the human thermal sensation, physiological equivalent temperature (PET) and universal thermal climate index (UTCI). As a result, the playground location had the highest thermal environment, and the roof (grass) location had the lowest. The mean difference between the two locations was 0.8-1.1℃ in air temperature, 1.8-4.0% in relative humidity, and 7.5-8.0℃ in mean radiant temperature. In open space locations, the wind speed was 0.4-0.5 ms-1 higher than others. Also, a wind tunnel effect happened at the Apt-center location during the afternoon. For the human thermal sensation, PET and UTCI, the mean differences between the playground and roof (grass) locations were: 5.2℃ (Max. 11.7℃) in late spring and 5.4℃ (Max. 18.1℃) in summer in PET; and 3.0℃ (Max. 6.1℃) in late spring and 2.6℃ (Max. 9.8℃) in summer in UTCI. The mean differences indicated a level change in PET and 1/2 level in UTCI, and the maximum differences showed greater changes, 2-3 levels in PET, and 1-1.5 levels in UTCI. Moreover, the roof (grass) location gave 4.6℃ PET reduction and a 2.5℃ UTCI reduction in late spring, and a 4.4℃ PET reduction and a 2.0℃ UTCI reduction in the summer when compared with the roof (cement) location, which results in a 2/3 level change in PET and a 1/3 level in UTCI. Green infrastructure locations [roof (grass), ground, and a tree-lined road] were not statistically significant in the reduction of PET and UTCI in thermal environment modifying effects. The implementation of green infrastructure, such as rooftop gardens, grass pavement, and street tree planting, should be adopted in landscape planning and be employed for human thermal environment modification.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

Pergola's Shading Effects on the Thermal Comfort Index in the Summer Middays (여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.52-61
    • /
    • 2013
  • This study was conducted to investigate the effects of pergola's shading on the thermal comfort index in the summer. The 3 type of pergolas($4m{\times}4m{\times}h2.7m$) which were screened overhead(I)/overhead west(II)/overhead west north(III) plane with reed blind for summer shading and winter wind break, were constructed on the 4th floor rooftop. Thereafter the meteorological variables(air temperature, humidity, radiation, and wind speed) of pergola I, III and rooftop were measured from 14 to 16 August 2013(1st experiment), those of pergola I, II and rooftop were measured from 26 to 28 August 2013(2nd experiment). The effects of pergola's shading on the radiation environment and mean radiant temperature($T_{mrt}$), standard effective temperature($SET^*$) were as follows. The maximum 1 h mean values of differences ${\Delta}$ of the sums of shortwave radiant flux densities absorbed by the human body (${\Delta}K_{abs,max}$) between pergola I, III and nearby sunny rooftop were $-119W/m^2$, $-158W/m^2$, those between pergola I, II and rooftop were $-145W/m^2$, $-159W/m^2$. The maximum 1 h mean values of differences ${\Delta}$ of the sums of long wave radiant flux densities absorbed by the human body (${\Delta}L_{abs,max}$) between pergola I, III and nearby sunny rooftop, were $-15W/m^2$, $-17W/m^2$, those between pergola I, II and nearby rooftop, were $-8W/m^2$, $-7W/m^2$. The response of the direction dependent long wave radiant flux densities $L_1$ on the pergola's shading turned out to be distinctly weaker as compared to shortwave radiant flux densities $K_1$. The pergola's shading leads to a lowering of $T_{mrt}$ and $SET^*$. The peak values of $T_{mrt}$ absorbed by the human body were decreased $16^{\circ}C$ and $21.4^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $18.8^{\circ}C$ and $20.8^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The peak values of $SET^*$ absorbed by the human body were decreased $2.9^{\circ}C$ and $2.6^{\circ}C$ under pergola I and III as compared to that of nearby rooftop in the 1st experiment. Those were decreased $3.5^{\circ}C$ and $2.6^{\circ}C$ under pergola I and II as compared to that of nearby rooftop in the 2nd experiment. The relative $SET^*$ decrease in pergola II, III compared to nearby sunny rooftop $SET^*$ were lower than that in pergola I, revealing the influence of the wind speed. Therefore it is essential to design pergola to maximize wind speed and minimize solar radiation to achieve comfort in the hot summer. The $SET^*$ under pergola I, III were exceeded $28.7^{\circ}C$ and $30.4^{\circ}C$ which were the upper limit of thermal comfort and tolerable zone during all most daytimes in the 1st experiment(maximum air temperature $37.5^{\circ}C$). The $SET^*$ under pergola I was exceeded $28.7^{\circ}C$ which was the upper limit of thermal comfort zone at 13h, that under pergola II was exceeded $28.7^{\circ}C$ from 8h to 14h, meanwhile the $SET^*$ under pergola I, II were within thermal tolerable zone during most daytimes in the 2nd experiment(maximum air temperature $34.4^{\circ}C$). Therefore to ensure the thermal comfort of pergola for summer hottest days, pergola should be shaded with not only reed blind but also climbing and shade plants. $T_{mrt}$ and $SET^*$ were suitable index for the evaluation of pergola's shading effects and outdoors.

A Study on Temperature Change Profiles by Land Use and Land Cover Changes of Paddy Fields in Metropolitan Areas (대도시 외곽지역 논경작지의 토지이용 및 피복변화에 따른 온도 변화모형 연구)

  • Ki, Kyong-Seok;Lee, Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • The purpose of this study is to understand the scale of temperature change following large-scale urban developments in paddy fields to present possible measures to preserve suburban area paddy fields and to lower the scale of temperature increase after developing paddy fields in urban areas. The study was conducted in Bupyeong and Bucheon of Incheon Metropolitan City. The satellite image($1989{\sim}2000$) before and after the development of old paddy fields were used to analyze the land surface temperature changes according to the land use types. Building coverage, green coverage, non-permeable pavement coverage, and floor area ratio(FAR) were selected as the factors that influence urban temperature changes and the temperature estimation model was constructed by using correlation and regression analyses. The before and after satellite images of Bupyeong and Bucheon were classified into forests, greens and plantations, paddy fields, unused lands, and urban areas. The results indicate that most of the paddy fields that existed in the center of Bupyeong and Bucheon were converted into unused lands which were undergoing construction to become new urban areas. The difference between the surface temperatures of May 17th, 1989 and May 7th, 2000 was analyzed to reveal that most land converted from paddy fields to unused lands or urban areas saw an increase in surface temperature. Han River was used as a comparison to analyze the average surface temperature changes($1989{\sim}2000$) in former paddy fields. The scale of temperature changes were: $+1.6697^{\circ}C$ in urban parks; $+2.5503^{\circ}C$ in residential zones; $+2.9479^{\circ}C$ on public lands, $+3.0385^{\circ}C$ in commercial zones, and $+3.1803^{\circ}C$ in educational zones. The correlation between building coverage, green coverage, non-permeable pavement coverage, or floor area ratio(FAR) and surface temperature increases was also analyzed. The green coverage to temperature increases, but building coverage, non-permeable pavement coverage, and floor area ratio(FAR) had no statistically significant temperature increases. The factors that influence urban temperature changes were set up as independent variables and the surface temperature changes as dependent variables to construct a surface temperature change model for the land use types of former paddy fields. As a result of regression analysis, green coverage was selected as the most significant independent variable. According to regression analysis, if farmland is converted into an urban area, a temperature increase of $+3.889^{\circ}C$ is anticipated with 0% green coverage. The temperature saw a decrease of $-0.43^{\circ}C$ with every 10% increase of green coverage.

Analysis of Meteorological Factors when Fine Particulate Matters Deteriorate in Urban Areas of Jeju Special Self-Governing Province (제주특별자치도 도시지역 미세먼지 악화 시 기상요소 분석)

  • Sin, Jihwan;Jo, Sangman;Park, Sookuk
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.36-58
    • /
    • 2022
  • In this study, the weather conditions corresponding to the increase in the environmental concentration of fine dust (PM10) and ultrafine dust (PM2.5) from 2001 to 2019 in Jeju and Seogwipo cities were analyzed. The increase in the levels of PM10 and PM2.5 was observed in the order: spring > winter > autumn > summer. In both cities, PM10 and PM2.5 levels increased more frequently during the day in spring and summer and at night in autumn and winter, with PM2.5 showing a greater increase in concentration than PM10. The air temperature and wind speed corresponding with increased levels of PM10 were higher than their respective seasonal averages in spring and winter, but lower in summer and autumn. Relative humidity was lower than the seasonal average during all seasons. The air temperature variation corresponding with increased levels of PM2.5 showed the same seasonal trend as that observed for PM10. The relative humidity was higher than the respective seasonal averages in spring and summer, and lower in winter. The wind speed was lower than the seasonal average in both the cities. When the PM10 and PM2.5 levels increased, the wind direction was from the north and the west during the day and varied according to the season at night. The rate of the increase in the PM10 concentration was the highest in both cities at the wind speed of 1.6 - 3.4 ms-1 during the day and night except during night in the summer. The highest concentration of PM2.5 was observed with the wind speed range of 1.6 - 3.4 ms-1 in Jeju, and 0.3 - 1.6 ms-1 in Seogwipo. The results of this study applied to urban and landscape planning will aid in the formulation of strategies to reduce the adverse effects of fine particular matter.

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.