• 제목/요약/키워드: 기밀성능

검색결과 212건 처리시간 0.02초

공동주택에서 기밀성능과 차음성능과의 상관성 연구 (A Study on the Correlation between Air-tightness and Sound Insulation in the Apartment Housing)

  • 박철용;홍구표;최지혜;이용대;최준석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.296-297
    • /
    • 2013
  • We have investigated correlation between airtightness measured by blower door and airborne sound insulation measured in the upper and lower units. We consist of two cases : all windows sealed(CASE 1) and not sealed(CASE 2). As a result, CASE 1 is tighter than CASE 2 in airtightness, but CASE 1 is lower than CASE 2 in sound level difference. This is because of big wind on measuring CASE 1. Thus we are going to measure them at another fields considering this factor. Finally we ought to find out the correlation between airtightness and sound insulation.

  • PDF

금속오링씰의 컴플라이언트 메커니즘 위상최적설계 (Compliant Mechanism Topology Optimization of Metal O-Ring)

  • 김근홍;이영신;양형렬
    • 대한기계학회논문집A
    • /
    • 제37권4호
    • /
    • pp.537-545
    • /
    • 2013
  • 금속씰의 탄성복원력은 기밀성능을 결정하는 매우 중요한 요소이다. 본 연구는 장시간 운전조건에서 기밀성능을 유지할 수 있는 금속오링씰의 구조, 즉 탄성복원력이 우수한 구조를 얻기 위하여 컴플라이언트 메커니즘 위상최적화법을 도입하였다. 진화구조최적화법의 위상최적화 알고리듬이 사용되었으며, 강성 및 유연성을 동시에 고려하는 두 가지 종류의 목적함수가 사용되었다. 금속오링씰의 외형을 고려하여 원형의 최적화 설계영역이 고려되었으며 최적화 결과로 나타난 위상의 탄성복원력은 상용품의 탄성복원력과 비교되었다.

대규모 건물의 기밀성능 측정기준 수립에 관한 연구 (Study on the Establishment of Large Building Airtightness Measurement Standards)

  • 이동석;지경환;조재훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

신한옥 침실 공간의 기밀성능 평가 연구 (A Study on the Airtightness Performance of New Han-ok Bedrooms)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

공동주택의 기밀성능에 따른 실외 유입 및 실내 발생 PM2.5의 계절별 실내농도 기여도 분석 (Seasonal Contribution of Indoor generated- and Outdoor Originating PM2.5 to Indoor Concentration Depending on Airtightness of Apartment Units)

  • 박보람;최동희;강동화
    • 대한건축학회논문집:구조계
    • /
    • 제36권2호
    • /
    • pp.155-163
    • /
    • 2020
  • Indoor airborne particles are consisted of outdoor- and indoor-generated particles, which can be characterized by their compositions, generation features and toxicity. The identification of source contribution of indoor and outdoor origin to indoor particles is important to understand PM2.5 transport in a building as well as its impact on occupant health. The objective of this study is to investigate seasonal source contribution to indoor PM2.5 concentration depending on airtightness of apartment units. To evaluate the source contribution, particle transport including penetration, generation, exfiltration in an apartment housing unit was simulated by using CONTAM with particle and airflow simulation parameters obtained from field measurements. The result showed that the outdoor source contribution to indoor air was relatively dominant in the leaky housing unit during spring (77.2%) and winter (73.9%), and the indoor source was dominant in the airtight housing unit during summer (60.3%) and fall (60.7%). These results indicate the seasonal health risk of indoor PM2.5 can be varied according to airtightness of apartment units.

전자기밀문서 유출봉쇄 유통시스템 구조 연구 (Study of Document Distribution System Architecture for Digital Secret Document Leakage Prevention)

  • 최정현
    • 인터넷정보학회논문지
    • /
    • 제11권4호
    • /
    • pp.143-158
    • /
    • 2010
  • 기업의 전자기밀유출은 생존을 위협하는 피해를 입힌다. 중소기업은 유출사실을 알아도 적절히 대응하지 못하는 현실에서 추적 불가능한 유출을 원천봉쇄하는 전자기밀보호 시스템으로만 전자기밀정보는 보호된다. 현재 DRM 기반 문서보호 시스템은 전자기밀 보호에 여러 보안 취약점을 보인다. 본 논문은 전자기밀정보의 불법유출 경로 및 취약점을 분석하여, 가장 위험한 내부자 유출시도조차 불가능하게 하는 보안조건을 만족시키면서도 성능저하가 없는 그룹통신 기반 시스템의 구조를 연구하였다. 구조의 핵심은 암호화 상태로 유통, 암호키와 기밀정보파일의 분리원칙, 다중 엔티티(entity)의 DSA 기반 다중 인증기법으로 간단한 정보도용으로는 기밀정보를 얻을 수 없는 시스템의 기본 구조의 설계를 논의한다.

고로슬래그 미분말 다량치환 콘크리트의 탄산화 억제를 위한 기밀성 향상재 부착효과 (The Surface Sealing Performance of Film, Air cap and Polystyrene foam for Preventing Carbonation of High-Volume Slag Concrete)

  • 한동엽;김경훈;한민철
    • 한국건축시공학회지
    • /
    • 제15권1호
    • /
    • pp.9-16
    • /
    • 2015
  • 친환경 건설 재료의 일환으로 고로슬래그 미분말을 다량치환한 콘크리트에 대해 재생골재를 이용해 잠재수경성 반응을 활성화 시켜 콘크리트로서의 활용방안 모색과 탄산화를 저감시킬 목적으로 다양한 기밀성 향상재를 표면에 부착하여 탄산화 저감효과를 측정하였다. 재생골재의 사용은 표면의 모르타르 및 미수화 시멘트로 인해 고로슬래그 미분말을 다량 치환한 콘크리트에 양호한 영향을 미친 것으로 판단되었다. 콘크리트 표면의 기밀성 향상재에 따른 탄산화 저감 효과는 기밀성 향상재 종류와 상관없이 콘크리트 표면에 효과적으로 부착되어 있는 경우라면 모두 양호한 탄산화 저감 성능을 나타내었다. 그러므로 시공이 용이하고 취급이 간편하며 콘크리트 표면에서 장기간 양호한 내구성을 발휘하는 기밀성 향상재로 선시공 1중 에어캡이 가장 양호한 방법으로 판단되었으며, 추가적으로 단열성능을 고려하였을 때에는 선시공 2중 에어캡이 효율적인 방법으로 생각해 볼 수 있었다.

단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능 (Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards)

  • 김세종;박주생
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.876-883
    • /
    • 2015
  • 국립산림과학원에서는 한옥의 전통건축기술을 바탕으로 한국형 기둥-보 목조주택인 ?그린 프로젝트를 2006년부터 진행해오고 있다. 최근에는 에너지 절약 기술요소를 적용하여 건물의 에너지성능을 개선하고자 하였다. 본 연구에서는 강화된 단열기준에 따른 기둥-보 목조벽체의 단열상세를 제시하고 그에 따른 건물 에너지 절감 효과를 평가하고자 하였다. 건물외피의 열관류율은 현행법 수준과 저에너지주택인 패시브하우스 수준인 두 단계로 나누었으며 건물에너지 성능을 평가하기 위하여 건물의 기밀성능은 국내 신축 목조주택 수준인 $3.0h^{-1}$과 패시브하우스 수준이 $0.6h^{-1}$ 두 단계로 나누어 열관류율과 기밀성능의 조합에 따라 4가지 경우에 대한 건물에너지 성능 평가가 이루어졌다. 대상건물은 서울에 위치하였으며 에너지 성능은 상용 건물에너지성능 평가 프로그램인 CE3가 사용되었다. 강화된 열관류율에 따라 시뮬레이션을 진행한 결과 연간 난방에너지 요구량은 $14kWh/(m^2{\cdot}a)$ 절감효과를 나타냈다.

차음성능이 향상된 경량벽체 개발 및 성능평가 연구 (A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF