• Title/Summary/Keyword: 기둥보강

Search Result 467, Processing Time 0.03 seconds

Seismic Resistance of Concrete-filled U-shaped Steel Beam-to-RC Column Connections (콘크리트채움 U형 강재보 - 콘크리트 기둥 접합부의 내진성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Lee, Cheol-Ho;Park, Chang-Hee;Lee, Chang-Nam;Kim, Hyoung-Seop;Kim, Sung-Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.83-97
    • /
    • 2011
  • In this study, the seismic details of a concrete-encased, U-shaped steel beam-to-RC column connection were developed. Three specimens of the beam-to-column connection were tested under cyclic loading to evaluate the seismic performance of the connection. The test parameters were the beam depth and the column section shape. The depths of the composite beams were 610 and 710 mm, including the slab depth. For the RC columns, a square section and a circular section were used. Special details using diagonal re-bars and exterior diaphragm plates were used to strengthen the connections with the rectangular and circular columns, respectively. The test results showed that the specimens exhibited good strength, deformation, and energy dissipation capacities. The deformation capacity exceeded 4% interstory drift angle, which is the requirement for the Special Moment Frame.

Numerical Modeling of Residual Behavior of Fire-Damaged Reinforced Concrete Interior Columns (화해를 입은 철근콘크리트 내부기둥의 잔존거동 수치해석 모델)

  • Lee Chadon;Shin Yeong-Soo;Lee Seung-Whan;Lee Chang-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.893-902
    • /
    • 2005
  • Reasonable prediction of residual capacity of fire-damaged reinforced columns is important for both the safety measurement and the rehabilitation of the reinforced concrete structures suffered from exposure to extensive fire. In order to predict the residual behavior of fire-damaged reinforced concrete columns, its predictive model must be able to take into account the amount of heat transferred into the column, the level of deterioration of constituent materials and various column geometries. The numerical model presented in this research includes all these factors. The model has been shown to reasonably predict the residual behavior of fire-damaged columns. Parametric studies were performed using this model for the effects of cover thickness, exposure time to fire and column geometries on the residual behavior of reinforced concrete columns. It was found that serious damage on the residual capacity of column resulted from a longer exposure time to fire but only marginal differences from other factors.

Uniaxial Compression Behavior of RC Columns Confined by Carbon Fiber Sheet Wraps (탄소섬유쉬트로 구속된 RC 기둥의 일축압축 거동)

  • Han, Sang-Hoon;Hong, Ki-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.207-216
    • /
    • 2005
  • External confinement by CFS (Carbon Fiber Sheet) is a very effective retrofit method for the reinforced concrete columns subject to either static or seismic loads. For the reliable and cost-effective design of CFS, an accurate stress-strain model is required for CFS-confined concrete. In this paper, uniaxial compression test on short RC column with square section was performed. To evaluate the effect of confinement on the stress-strain relationship of CFS-confined concrete, CFS area ratio and tie area ratio are considered. Based on the experimental results, a stress-strain model is proposed for concrete confined by CFS wraps. In the development of the model, the method to compute the actual hoop strains in CFS jackets at the rupture was examined and resolved. Overall, the results of the model agree well with test data.

Application of Concentrated FRP Bars to Enhance the Capacity of Two-Way Slabs (2방향 슬래브의 성능 향상을 위한 집중 배근된 FRP 바의 적용)

  • Lee, Joo-Ha;Yang, Jun-Mo;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.727-734
    • /
    • 2007
  • The influence of the differences in the physical and mechanical properties between fiber-reinforced polymer (FRP) and conventional steel, concentrated reinforcement in the immediate column region, as well as using steel fiber-reinforced concrete (SFRC) in the slab near the column faces, on the punching behavior of two-way slabs were investigated. The punching shear capacity, stiffness, ductility, strain distribution, and crack control were investigated. Concentrating of the slab reinforcement and the use of SFRC in the slab enhanced the punching behavior of the slabs reinforced with glass fiber-reinforced polymer (GFRP) bars. In addition the test results of the slabs with concentrated reinforcement were compared with various code equations and the predictions proposed in the literature specifically for FRP-reinforced slabs. An appropriate method for determining the reinforcement ratio of slabs with a banded distribution was also investigated to allow predictions to properly reflect the benefit of the slab reinforcement concentration.

Analysis of Lateral Retrofitting Effect by FRP and BRB for Beam-column Element Joint of Low-Rise Piloti Buildings (FRP시트와 비좌굴가새를 적용한 저층 필로티 구조물의 보-기둥 연결부 거동 해석에 관한 연구)

  • Kim, Min-Sook;Yoon, So-Hee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • The experiment was carried out to investigate lateral retrofitting effects by FRP and BRB (Buckling-Restrained Brace) for beam-column elements. These results were utilized to establish an analytical model using commercial nonlinear analysis software, PERFORM3D. Concrete and steel analytical models previously proposed by several scholars were adopted for this analytical study. A proposed analysis model showed reasonable accuracy compared with the test results on the beam-column elements strengthened FRP sheets and BRB, as well as with the non-strengthened element subjected to lateral cyclic loadings. Subsequently, the proposed modeling technique for nonlinear analysis would be helpful for preliminary analyses for retrofitting structures, by enabling engineers to estimate the improved capacity of retrofitted structural elements before performing construction.

Fire Resistance Performance of Recycling PET Fiber Reinforced High Strength Concrete Circular Column (재생 PET섬유 보강 고강도 콘크리트 원형기둥의 내화성능)

  • Seo, Tae-Seok;Gong, Min-Ho;Kwon, Hae-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.513-518
    • /
    • 2016
  • This study evaluates the fire resistance performance for 60MPa high strength concrete reinforced by recycling polyethylene-terephthalate(PET) fiber(fiber content : 0.05 vol.%). Because there is no fire resistance test results for circular concrete column, a fire resistance test was carried out for circular concrete column specimens. As a result, it was confirmed that PET fiber was effective against the spalling control of high strength concrete. However, the specimen with cover thickness 30mm did not satisfy the temperature standard of main reinforcement, and the specimen with cover thickness 40mm satisfied the temperature standard of main reinforcement. Therefore, more than 40mm cover thickness was demanded for stable fire resistance performance.

Performance Evaluation of Junctions between Multi-Tubular and Cylindrical Sections for Steel Wind Tower (멀티기둥-강관 풍력타워 연결부 성능 평가)

  • Kim, Jongmin;Park, Hyun-Yong;Kim, Kyungsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1764-1769
    • /
    • 2014
  • Numerical investigations have been conducted on the junction that connect the multi-tubular section and the single shell section in order to evaluate applicability of hybrid sections in wind turbine towers instead of conventional single shell towers. Major characteristics in structural details include extension of multi-tubular member into shell end section, installation of wing stiffeners, and different layout of floor beams. Elastic and nonlinear incremental analyses were conducted to examine stress concentration patterns and ultimate behaviors, respectively. Based on evaluation of structural performance due to vertical and horizontal forces, it has been confirmed that installation of floor beams and wing stiffeners sensitively affect ultimate strength of global wind tower.

An Evaluation on Punching Shear Capacity of R/C Flat Plate Slab (RC 플랫 플레이트 슬래브의 뚫림전단성능평가)

  • Kim, Jong-Keun;Shin, Sung-Woo;Yang, Ji-Soo;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.205-213
    • /
    • 2003
  • The primary purpose of this study is to investigate punching shear capacity of flat plate slab using high strength concrete in column. It may be much contributed to economy efficiency and structural advantages that High Strength Concrete(HSC) used for vertical member and Normal Strength Concrete(NSC) for horizontal member. Therefore, six plate flat slab specimens with HSC column and NSC slab had been made and tested with real scale. The major variables were compressive strength of concrete(fck=285, $460kgf/cm^2$), extended length of HSC from column face and amount of shear reinforcements. As the result of this test, the maximum load and punching shear capacity of specimens is affected by extended length and shear reinforcements.

Experimental Study on Concrete Steel Circular Tubes Confined by Carbon Fiber Sheet under Axial Compression Loads (탄소섬유쉬트로 구속된 콘크리트충전 원형강관기둥의 단조압축실험)

  • Park, Jai-Woo;Hong, Young-Kyun;Hong, Gi-Soup;Choi, Sung-Mo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.61-71
    • /
    • 2009
  • This paper presents the results of an experiment comparing the current circular CFT columns and circular CFT columns that were additionally confined by carbon fiber sheets (CFS) under axial loading. The main experimental parameters are the numbers of CFS layers and the diameter-to-thickness ratio. 10 specimens were prepared according to the experimental parameter plans, and axial compression tests were conducted. From the tests, the failure procedure, load-axial deformation curve, maximum axial strength, and deformation capacity of the CFT columns and confined CFT columns were compared. The test results showed that the maximum axial strengths of CFT columns additionally confined by CFS are increased higher than those of the current CFT columns, and that local buckling can be delayed due to the confinement effect of CFS.

Fire Resistance Performance for Fiber Reinforced High Strength Concrete Column Member (폴리프로필렌 및 강섬유 보강 고강도 콘크리트 기둥부재의 내화성능)

  • Jang, Chang-Il;Lee, Sang-Woo;Choi, Min-Jung;Kim, Joon-Mo;Kim, Heung-Youl;Won, Jong-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.457-460
    • /
    • 2008
  • This study evaluated fire resistance performance for polypropylene/steel fiber reinforced high strength concrete column. Full-size columns were constructed and tested with or without fibers using ISO-834 fire curve. As the result of test, non-fiber high strength concrete column specimen occurred serious spalling and indicated rapidly internal temperature increase. Specimen with polypropylene fiber occurred not spalling. Specimen with hybrid fiber occurred not spalling as well as does not propagated temperature propagation. Therefore, hybrid fiber reinforced column specimen indicated a good fire resistance performance than other cases.

  • PDF