• Title/Summary/Keyword: 기능적 의료영상

Search Result 97, Processing Time 0.026 seconds

Analysis of Fractional Anisotropy Measurements of Diffusion Tensor Images in the Gyrus of the Brain by AUDIT-K Scale (AUDIT-K 척도에 따른 뇌 이랑 부위의 확산텐서 비등방도 측정값 분석)

  • Kwak, Jong-Hyeok;Kim, Gyeong-Rip;Cho, Hee-Jung;Lee, Eun-Sook;Sung, Soon-Ki
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.176-185
    • /
    • 2019
  • Diffusion tensor images were obtained for middle-aged men according to the AUDIT-K scale. As a result of the fractional anisotropy (FA) value of the gyrus nerve fibers in the brain region measured and analyzed by the Tract-Based Spatial Statics, FA values of general drinkers were measured lower than those of estimated alcohol use disabled people. This was statistically significant. In other words, the use of alcohol significantly affects the anatomic microstructural changes measured in the Gyrus of the brain region, and it may damage the nerve fiber tract and affect the functional abnormalities associated with it.

특집 : IT 융복합의료기기 기술 - 혈액순환 증진을 위한 족부자극 장치 및 3D 시각화 기술

  • Jeong, Gyeong-Yeol;Im, Byeong-Ju;Park, Chang-Dae;Choe, Dae-Seok;Kim, Gwon-Tae
    • 기계와재료
    • /
    • v.23 no.1
    • /
    • pp.34-43
    • /
    • 2011
  • 최근 노령화와 스포츠 인구의 증가로 인해 족부 혈액순환 장애 및 족관절의 퇴행성 질환이 증가하고 있으며 이로 인해 몸의 평형기능 및 운동성에 기능장애가 동반하게 된다. 이로 인해 일상생활 기능 저하와 낙상과 같은 이차적 합병증 발생을 초래하여 기능 및 삶의 질 저하, 활동제한 등으로 건강한 노년에 대한 심각한 위협 요인이 될 수 있다. 따라서 족부 혈액순환 증진을 위해 IT기술을 활용하여 압력에 따른 부위별 자극의 세기를 달리하고, 3D영상을 통해 가공의 상황 및 가상의 환경을 사람의 감각을 통해 느끼게 하여 실제 상호작용하고 있는 것처럼 만들어 주어, 혈액순환 개선의 효과를 극대화하고자 노화에 따른 족부건강 변화 및 족부 자극의 효과를 분석하고, 가상현실을 기반으로 한 족부혈액 순환 증진 장치와 관련 컨텐츠에 대해 제시하고자 한다.

  • PDF

Development of JPEG2000 Viewer for Mobile Image System (이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2003
  • Currently, as a consequence of PACS (Picture Archiving Communication System) implementation many hospitals are replacing conventional film-type interpretations of diagnostic medical images with new digital-format interpretations that can also be saved, and retrieve However, the big limitation in PACS is considered to be the lack of mobility. The purpose of this study is to determine the optimal communication packet size. This was done by considering the terms occurred in the wireless communication. After encoding medical image using JPGE2000 image compression method, This method embodied auto-error correction technique preventing the loss of packets occurred during wireless communication. A PC class server, with capabilities to load, collect data, save images, and connect with other network, was installed. Image data were compressed using JPEG2000 algorithm which supports the capability of high energy density and compression ratio, to communicate through a wireless network. Image data were also transmitted in block units coeded by JPEG2000 to prevent the loss of the packets in a wireless network. When JPGE2000 image data were decoded in a PUA (Personal Digital Assistant), it was instantaneous for a MR (Magnetic Resonance) head image of 256${\times}$256 pixels, while it took approximately 5 seconds to decode a CR (Computed Radiography) chest image of 800${\times}$790 pixels. In the transmission of the image data using a CDMA 1X module (Code-Division Multiple Access 1st Generation), 256 byte/sec was considered a stable transmission rate, but packets were lost in the intervals at the transmission rate of 1Kbyte/sec. However, even with a transmission rate above 1 Kbyte/sec, packets were not lost in wireless LAN. Current PACS are not compatible with wireless networks. because it does not have an interface between wired and wireless. Thus, the mobile JPEG2000 image viewing system was developed in order to complement mobility-a limitation in PACS. Moreover, the weak-connections of the wireless network was enhanced by re-transmitting image data within a limitations The results of this study are expected to play an interface role between the current wired-networks PACS and the mobile devices.

  • PDF

Design and Development of Middleware for Clinical Trial System based on Brain MR Image (뇌 MR 영상기반 임상연구 시스템을 위한 미들웨어 설계 및 개발)

  • Jeon, Woong-Gi;Park, Kyoung-Jong;Lee, Young-Seung;Choi, Hyun-Ju;Jeong, Sang-Wook;Kim, Dong-Eog;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.805-813
    • /
    • 2012
  • In this paper, we have designed and developed a middleware for an effectively approaching database to the existed brain disease clinical research system. The brain disease clinical research system was consisted of two parts i.e., a register and an analyzer. Since the register collects the registration data the analyzer yields a statistical data which based on the diverse variables. The middleware has designed to database management and a large data query processing of clients. By separating the function of each feature as a module, the module which was weakened connectivity between functionalities has been implemented the re-use module. And image data module used a new compression method from image to text for an effective management and storage in database. We tested the middleware system using 700 actual clinical medical data. As a result, the total data transmission time was improved maximum 115 times faster than the existing one. Through the improved module structures, it is possible to provide a robust and reliable system operation and enhanced security functionality. In the future, these middleware importances should be increased to the large medical database constructions.

A Study on the Improvement Model of Administrative Information Dataset Records Management Environment: Focused on the Dataset of Picture Archiving and Communication System (행정정보 데이터세트 기록관리 환경개선 모델 연구: 의료영상저장전송시스템(PACS)의 데이터세트를 중심으로)

  • Lee, Sun-kyung
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.22 no.2
    • /
    • pp.51-73
    • /
    • 2022
  • Currently, an implementation plan of administrative information dataset record management has been prepared; however, analyzing the specificity of various administrative information systems and preparing a reasonable level of management reference table by applying about 1.3% (EA portal registration system: 16,199, consulting system: 214) has its limitations. This study started by recognizing the importance of the records management environment in administrative information datasets. Based on the described information, the current records management environment was analyzed by dividing the six areas of the management reference table of the picture archiving and communication system (PACS) into three groups. Thus, a systematic environmental improvement model was proposed, enhancing the effectiveness of dataset records management in the field. Although there is a limitation in analyzing one of the dataset records management environments of various institutions, it is intended to help broaden the horizons of records management research.

A Survey and Comparison of 3D Registration of Brain Images Between Marker Based and Feature Based Method (마커 기반과 특징기반에 기초한 뇌 영상의 3차원 정합방법의 비교 . 고찰)

  • 조동욱;김태우;신승수;김지영;김동원;조태경
    • The Journal of the Korea Contents Association
    • /
    • v.3 no.3
    • /
    • pp.85-97
    • /
    • 2003
  • Medical tomography images like CT, MRI, PET, SPECT, fMRI, ett have been widely used for diagnosis and treatment of a patient and for clinical study in hospital. In many cases, tomography images are scanned in several different modalities or with time intervals for a single subject for extracting complementary information and comparing one another. 3D image registration is mapping two sets of images for comparison onto common 3D coordinate space, and may be categorized to marker -based matching and feature-based matching. 3D registration of brain images has an important role for visual and quantitative analysis in localization of treatment area of a brain, brain functional research, brain mapping research, and so on. In this article, marker-based and feature-based matching methods which are often used are introduced.

  • PDF

A Design and Implementation of MINI-PACS Employing the DICOM Converter on Web Environment (웹 상에서 DICOM 변환기를 이용한 MINI-PACS 설계 및 구현)

  • Ji, Youn-Sang;Rhee, Kang-Hyeon;Chung, Il-Yong;Lee, Sung-Joo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.4
    • /
    • pp.39-49
    • /
    • 2001
  • Application of information system to hospital would bring innovative improvement on efficiency of business management and provide high quality services toward patients as well as the retrenchment of operating funds. PACS(Picture Archiving and Communication System) including X-ray film that manages the medical image information effectively, has drawn considerable attention to essential structural elements to the sophisticated information system for hospital. PACS system should be connected to the network after making a form of standard medical image file from different style of image information obtained from various medical instruments. In this paper, to solve this problem, we construct Mini-PACS that converts the form of Non-DICOM file to the form of standard file by designing the DICOM converter. This system is designed to be managed under Web environment. Comparing with the existed Mini-PACSs, consisting of the client and server module, our system is designed and implemented with integration of these functions in order to be strongly combine strongly between system.

  • PDF

A Study on Urine Analyzer Using Color Images of Strip (스트립의 컬러영상을 이용한 요 분석기에 관한 연구)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.7
    • /
    • pp.919-923
    • /
    • 2007
  • This paper presents an urine analyzer using color images of strip. An image sensor has been used to acquire an color images. The analyzer has a characteristics which takes a pictures of independent each pad responding to urine items all at once, and outputs the measured urine values by analysing an acquired pad colors. This device measures and analyses 11 urine items, and has a speed-up operation, light weight, small size, and makes accurate observations by processing the measured colors using processor. The urine analyzer transmits the urine items to peripheral devices, personal computers, hospitals, and another places by using a telegraph and a wireless interfaces.

A Case Report of Echocardiography of Non-rheumaic Giant Left Atrium (비-류마티스성 거대 좌심방의 심장 초음파 검사 증례 보고)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.443-451
    • /
    • 2022
  • In this case, non-rheumatic GLA was observed and it was intended to report a case of ultrasound examination. The case patient, a 60-year-old male, visited the emergency room for dyspnea and palpitations. For radiology examination, chest X-ray examination and CT examination were performed, and a giant left atrium was confirmed. Echocardiography was performed to find the cause of the giant left atrium. Echocardiography The size and volume of the left atrium were evaluated by Simpson's method, and the giant left atrium with LVEDVI 6 times larger than that of the general giant left atrium could be evaluated. Also, a giant left atrium in a patient without rheumatic heart disease is evaluated as a very rare case. Since non-rheumatic giant left atrium could be caused by functional mitral regurgitation, diastolic dysfunction. It was confirmed that ultrasonography, which allowed both morphological and hemodynamic examinations, could be a useful case.

A Study for the Implementation of the DICOM Toolkit Software (DICOM 툴킷 소프트웨어 구현에 관한 연구)

  • Shin Dong Kyu;Kim Dong Youn;Kim Dong Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.481-486
    • /
    • 2003
  • This paper describes the implementation of the toolkit software for the DICOM. the international standards of medical imaging. Well known toolkits do not have the functions related to imaging or ported to Windows OS after developed at UNIX OS or do not have mechanism for the speed and memory management or have complicated structure comes from DICOMI complexity. The toolkit introduced in this paper was designed for the hospital environments. It handles mass images at Windows based PC system. supports multi-threading to enhance the efficiency. supports every functions in Object Oriented Programming style needed at clinical application which makes the rapid development of the DICOM related applications. The results says that the toolkit can display 50 CT, 50 MR, 10 CR and 10 DX images in 12 seconds and occupy small quantity of physical memory at usual PC system.