• Title/Summary/Keyword: 기관출력

Search Result 233, Processing Time 0.025 seconds

An Automatic AC-DC Transfer Error Measurement System (교류-직류 변환오차 자동 측정시스템)

  • Kwon, Sung-Won;Cho, Y.M.;Kim, K.T.;Kang, J.H.;Park, Y.T.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.401-408
    • /
    • 1998
  • A dual-channel automatic ac-dc voltage transfer error measurement system in which the output voltages of two thermal voltage converters which are ac voltage standard are directly measured at the same time to reduce the output voltage drift is described. Forward-reverse measurement method by using a two-channel scanner is used to cancel the offset voltage of the voltmeters. The agreements of the 4-V TVC comparison results between other national standards institute and Korea Research Institute of Standards and Science were less than about ${\pm}2\;ppm$ in the frequency range of $40\;Hz{\sim}100\;kHz$, and were less than about ${\pm}4\;ppm$ at $200\;kHz{\sim}1\;MHz$. Measurement uncertainty is reduced significantly from ${\pm}4\;ppm$ of manual system to ${\pm}3\;ppm$ of new system(up to 100 kHz) typically and great increase in comparison efficiency has been achieved by this system.

  • PDF

Sterilization Effect by the Nd:YAG Laser pulse (Nd:YAG 레이저 펄스에 따른 멸균효과)

  • Jeong, Kyeonghwan;Jung, Dongkyung;Park, Jeongkyu;Choi, Hyeonwoo;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.695-703
    • /
    • 2020
  • The use of medical devices is increasing due to the development of medical technology. Among medical devices, it is often used in the human body for graft and treatment. Therefore, in medical institutions, various sterilization methods according to the type and material of medical devices are applied to prevent infection. Hydrophosphite (HA) materials are the most popular in bone grafts. We would like to present a sterilization method using Q-switch Nd:YAG laser with high output energy among non-ionizing radiation suitable for small medical devices. In this study, sterilization power was most ideally shown at UV wavelengths of 1.5 W, 266 nm, and 10 pulses. Different wavelength bands; infrared and visible light; showed passive sterilization, and ultraviolet A and C showed differences in sterilization according to the pulse. In laser sterilization were differences that found according to the wavelength bands and pulses.

A computation module to compensate the power factor at 2 parameter equivalent circuit for modelling 3 phase induction motors (2 회로정수 방식 3상유도전동기 등가회로에서의 역률보상 연산모듈)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.8
    • /
    • pp.1195-1202
    • /
    • 2010
  • When modelling lots of induction motors to design and configure an engine room simulator, the 2 parameters equivalent circuit has many practical benefits as it reduces working hours considerably without requiring complicated technical data from makers except the ratings of motors. The basic properties such as torque and load current are shown well matched with real cases by this method, but almost the only drawback of 2 parameters circuit is that it reveals inherently higher power factor in the whole operation range due to disregarding the exciting current of the induction motor to maximize the simplification. This paper suggests a modelling module as a practical tool to compensate the power factor by inserting a virtual compensation current into the load current from 2 parameters equivalent circuit, and the simulated results show satisfactory outputs and the improved power factor indication by performance curves when compared to the cases of 2 parameters-equivalent circuit.

APMP (Asia Pacific Metrology Programme) Regional Intercomparison Results of Acoustic Calibrators (음향교정기의 아시아.태평양 지역 국제비교 결과)

  • 서상준;서재갑;조문재
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.463-471
    • /
    • 2003
  • The results of the APMP (Asia Pacific Metrology Programme) regional intercomparison of acoustic calibrators were reviewed and analyzed. The artefacts used in intercomparison are a sound level calibrator and a pistonphone. The microphones used to measure the output pressure level are 1" and 1/2" standard microphones (LS1P, LS2P) as well as 1" and 1/2" reference microphones (WS1P/F, WS2P/F). The results obtained using standard microphones are satisfactory, but those obtained by the reference microphones, even though E/sub n/ values are within ±1.0, showed great deviations. Such results had come from the inaccurate calibration of reference microphones. By using the correct calibration results which were obtained by the recently established international standards, the new results were very similar to those of the foreign standard institutes.

Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system (시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.141-146
    • /
    • 2001
  • It is well known that assurance of the radiation therapy needs for an accuracy of $\pm$ 5 % in the delivery of an absorbed dose to target volume. Therefore, the dose evaluation of brachytherapy source and/or linear accelerate beam must be a stability with accuracy. In an advanced country, they recommended to use the radioactive check source for reference air ionization chamber for a stable response of radiation field chamber. In this experiments, the radioactive source Sr-90 and PR-05 air ionization chamber were used for standard source and reference ion chamber. The response of reference ion chamber showed as an 1.000$\pm$ 0.010 uncertainty for 10 years long and the evaliuation f dose discrepancy of clinical field ion chamber showed as 0.997 $\pm$0.011 in a $^{60}$ Co brachytherapy soruce. In our experiments, we can assuarance the long halflife standard source is reliable to preserve the calibration factor of reference chamber in stability.

  • PDF

A Study on Economical Operation of a Ship's Main Engine - The case of Training Ship SAENURI - (선박 기관의 경제적 운전에 관한 연구 - 실습선 새누리호를 중심으로 -)

  • Kim, Hong-Ryeol;Kim, Bu-Gi;Rim, Geung-Su;Kim, Deug-Bong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.52-58
    • /
    • 2013
  • Operation Abstract : Operational cost required for navigating a ship may differ from according to type, scale, economic speed, navigation area and other factors. However, it is known that the fuel oil price ratio takes 50~60 %. It is the current trend because of the use of poor quality fuel and it is reviewed even for small to medium sized ships to save the operational costs due to the recent rise of international oil price. Furthermore, ocean carriers are taking action to low speed navigation as the alternative method of reducing fuel consumption. Hence, in this study, fuel consumption of main engine was measured by using actual operating ship data compared with sea speed at sea. It was suggested that the area of M/E's load(70 %) lower than NCR is the optimal navigating condition through the relation between speed and fuel consumption compared with advance ratio together with the load.

A Machine Learning-Based Method to Predict Engine Power (머신러닝을 이용한 기관 출력 예측 방법에 관한 연구)

  • KIM, Dong-Hyun;HAN, Seung-Jae;JUNG, Bong-Kyu;Han, Seung-Hun;LEE, Sang-Bong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.851-857
    • /
    • 2019
  • This study is about ship horsepower prediction of machine learning method using the big data of ship. Currently, new ships use the ISO15016 method to predict external environmental resistance through mathematical equations but due to complicated equations and requires many input variables so it is less applicable to be used in ship. In this recent research, we propose a model capable of predicting ship performance with high performance using SVM (Support Vector Machine) algorithm which shows excellent performance in recent prediction and recognition. The proposed predictive model has the advantage of being able to predict better performance than ISO15016 only if secured big data is used. In this study, we compared the ISO15016 technique and the SVM algorithm-based horsepower analysis method using the 178K bulk carrier's voyage data to reduce ship model data preparation, which is a disadvantage of ISO15016, and improve inaccurate horsepower prediction performance.

It's effects for engine emission of water/oil emulsified fuel (Water/Oil 에멀젼 연료가 배출가스에 미치는 영향)

  • Kim, Moon-Chan;Lee, Chang-Suk
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.159-166
    • /
    • 2008
  • In this study, the characteristics of emulsified fuel and engine emissions were studied. Emulsified fuel which composed of water and diesel was manufactured by using homogenizer and ultrasonic generator. Engine emissions were studied whit engine dinamometer. In emulsified fuel, density and viscosity were increased with increasing water contents, but viscosity was decreased over 60% of water in emulsion fuel. The emulsion type of W/O changed to that of O/W over 60% of water in emulsion fuel. In the results of engine dinamometer test, NOx concentration and smoke density were reduced with increasing water contents in emulsified fuel but reciprocal in the case of THC, CO. Temperature and power were reduced with increasing water contents in emulsion fuel. In conclusion, it seemed that using emulsified fuel for diesel engine was effective for reducing NOx concentration and smoke density.

Determination of Optimum Size of Power Tiller (소형(小型) 동력경운기(動力耕耘機)의 적정(適正) 설계(設計)에 관한 연구(硏究) - 기관출력(機關出力)과 중량(重量)을 중심(中心)으로 -)

  • Ryu, Kwan Hee;Kim, Kyeong Uk;Choi, Kyu Hong;Park, Keum Ju
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-12
    • /
    • 1985
  • The two agricultural zones, mid-and-northen region and southern region, were established according to the possibility of double cropping in the paddy field. For each agricultural zone typically mechanized farming systems with a power tiller for cultivating rice, barley and soybean were established. A computer program, which determines the optimum size of power tiller for the given farm size, the ratio of paddy area to total area and the ratio of double cropping area to the paddy area, was developed. The computer program was executed for the farm sizes, 1 to 3 ha, and the ratios of paddy area to the total area, 60~80%, and the ratio of double cropping area to the total paddy area, 70%. The following conclusions were drawn from analyzing the computer outputs. 1. In the mid-and-northern region, a smaller power tiller (5 or 6 PS) appeared to be more economical for the farm size up to 3 ha. From the viewpoint of fuel consumption a 6 PS power tiller appeared to be more favorable. 2. In the southern region, a smaller tiller (5 or 6 PS) appeared to be more economical for the farm size up to 1.5 ha. But, a larger power tiller (8 or 10 PS) appeared to become more economical as the farm size and the barley planted area increased. 3. For the southern region where rotary tilling is heavily required due to double cropping, it is recommended to develop a power tiller which weighs light like the conventional 5 or 6 PS small power tiller but has lager power.

  • PDF

Development and Operation of Marine Environmental Portal Service System (해양환경 포탈서비스시스템 구축과 운영)

  • 최현우;권순철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.338-341
    • /
    • 2003
  • According to a long-term master plan for the implementing of MOMAF's marine environmental informatization, we have developed marine environment portal web site which consists of 7 main-menu and 39 sub-menu including various types of contents (text, image and multimedia) based on RDBMS. This portal site was opened in Oct., 2002 (http://www.meps.info). Also, for the national institutions' distributed DB which is archived and managed respectively the marine chemical data and biological data, the integrated retrieval system was developed. This system is meaningful for the making collaborative use of real data and could be applied for data mining, marine research, marine environmental GIS and making-decisions.

  • PDF