• Title/Summary/Keyword: 기계적 주변기기

Search Result 26, Processing Time 0.023 seconds

Optimization and Application Research on Triboelectric Nanogenerator for Wind Energy Based High Voltage Generation (정전발전 기반 바람에너지 수확장치의 최적화 및 고전압 생성을 위한 활용 방안)

  • Jang, Sunmin;Ra, Yoonsang;Cho, Sumin;Kam, Dongik;Shin, Dongjin;Lee, Heegyu;Choi, Buhee;Lee, Sae Hyuk;Cha, Kyoung Je;Seo, Kyoung Duck;Kim, Hyung Woo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.243-248
    • /
    • 2022
  • As the scope of use of portable and wearable electronic devices is expanding, the limitations of heavy and bulky solid-state batteries are being revealed. Given that, it is urgent to develop a small energy harvesting device that can partially share the role of a battery and the utilization of energy sources that are thrown away in daily life is becoming more important. Contact electrification, which generates electricity based on the coupling of the triboelectric effect and electrical induction when the two material surfaces are in contact and separated, can effectively harvest the physical and mechanical energy sources existing in the surrounding environment without going through a complicated intermediate process. Recently, the interest in the harvest and utilization of wind energy is growing since the wind is an infinitely ecofriendly energy source among the various environmental energy sources that exist in human surroundings. In this study, the optimization of the energy harvesting device for the effective harvest of wind energy based on the contact electrification was analyzed and then, the utilization strategy to maximize the utilization of the generated electricity was investigated. Natural wind based Fluttering TENG (NF-TENG) using fluttering film was developed, and design optimization was conducted. Moreover, the safe high voltage generation system was developed and a plan for application in the field requiring high voltage was proposed by highlighting the unique characteristics of TENG that generates low current and high voltage. In this respect, the result of this study demonstrates that a portable energy harvesting device based on the contact electrification shows great potential as a strategy to harvest wind energy thrown away in daily life and use it widely in fields requiring high voltage.

Study of multi-stacked InAs quantum dot infrared photodetector grown by metal organic chemical vapor deposition

  • Kim, Jeong-Seop;Ha, Seung-Gyu;Yang, Chang-Jae;Lee, Jae-Yeol;Park, Se-Hun;Choe, Won-Jun;Yun, Ui-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.129-129
    • /
    • 2010
  • 적외선 검출소자(Infrared Photodetector)는 근적외선에서 원적외선 영역에 이르는 광범위한 파장 범위의 적외선을 이용하는 기기로서 대상물이 방사하는 적외선 영역의 에너지를 흡수하여 이를 영상화할 수 있는 장비이다. 적외선 관련 기술은 2차 세계대전 기간에 태동하였으며, 현재에는 원거리 감지기술 등과 접목되면서 그 활용 분야가 다양해지고 있다. 특히 능동형 정밀 타격무기를 비롯한 감시 정찰 장비 및 지능형 전투 장비 시스템 등에 대한 요구를 바탕으로 보다 정밀하고 신속한 표적 감지 및 정보처리 기술에 관한 연구가 선진국을 통해서 활발히 진행되고 있다. 기존의 Bolometer 형식의 열 감지 소자는 반응 속도가 느리고 측정 감도가 낮은 단점이 있으며, MCT(HgCdTe)를 이용한 적외선 검출기의 경우 높은 기계적 결함과 77K 저온에서 동작해야하기 때문에 발생하는 추가 비용 등이 문제점으로 지적되고 있다[1]. 이에 반해 화합물 반도체 자기조립 양자점(self-assembled quantum dot)을 이용한 적외선 수광소자는 양자점이 가지는 불연속적인 내부 에너지 준위로 인하여, 높은 내부 양자 효율과 온도 안정성을 기대할 수 있으며, 고성능, 고속처리, 저소비전력 및 저소음의 실현이 가능하다. 본 연구에서는 적층 InAs/InGaAs dot-in-a-well 구조를 유기금속화학기상증착법을 이용하여 성장하고 이를 소자에 응용하였다. 균일한 적층 양자점의 성장을 위해서 원자현미경(atomic force microscopy)을 이용하여, 각 층의 양자점의 크기와 밀도를 관찰하였고, photoluminescence (PL)를 이용하여 발광특성을 연구하였다. 각 층간의 GaAs space layer의 두께와 온도 조절 과정을 조절함으로써 균일한 적층 양자점 구조를 얻을 수 있었다. 이를 이용하여 양자점의 전도대 내부의 에너지 준위간 천이(intersubband transition)를 이용하는 n-type GaAs/intrinsic InAs 양자점/n-type GaAs 구조의 양자점 적외선수광소자 구조를 성장하였다. 이 과정에서 상부 n-type GaAs의 성장 온도가 600도 이상이 되는 경우 발광효율이 급격히 감소하고, 암전류가 크게 증가하는 것을 관찰하였다. 이는 InAs 양자점과 주변 GaAs 간의 열에 의한 상호 확산에 의하여 양자점의 전자 구속 효과를 저해하는 것으로 설명된다.

  • PDF

Reflow Behavior and Board Level BGA Solder Joint Properties of Epoxy Curable No-clean SAC305 Solder Paste (에폭시 경화형 무세정 SAC305 솔더 페이스트의 리플로우 공정성과 보드레벨 BGA 솔더 접합부 특성)

  • Choi, Han;Lee, So-Jeong;Ko, Yong-Ho;Bang, Jung-Hwan;Kim, Jun-Ki
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.1
    • /
    • pp.69-74
    • /
    • 2015
  • With difficulties during the cleaning of reflow flux residues due to the decrease of the part size and interconnection pitch in the advanced electronic devices, the need for the no-clean solder paste is increasing. In this study, an epoxy curable solder paste was made with SAC305 solder powder and the curable flux of which the main ingredient is epoxy resin and its reflow solderability, flux residue corrosivity and solder joint mechanical properties was investigated with comparison to the commercial rosin type solder paste. The fillet shape of the cured product around the reflowed solder joint revealed that the curing reaction occurred following the fluxing reaction and solder joint formation. The copper plate solderability test result also revealed that the wettability of the epoxy curable solder paste was comparable to those of the commercial rosin type solder pastes. In the highly accelerated temperature and humidity test, the cured product residue of the curable solder paste showed no corrosion of copper plate. From FT-IR analysis, it was considered to be resulted from the formation of tight bond through epoxy curing reaction. Ball shear, ball pull and die shear tests revealed that the adhesive bonding was formed with the solder surface and the increase of die shear strength of about 15~40% was achieved. It was considered that the epoxy curable solder paste could contribute to the improvement of the package reliability as well as the removal of the flux residue cleaning process.

Bending Impact Properties Evaluation of Sn-xAg-Cu Lead Free Solder Composition and aging treatment (시효처리한 Sn-xAg-Cu계 무연솔더 조성에 따른 굽힘충격 특성평가)

  • Jang, Im-Nam;Park, Jai-Hyun;Ahn, Yong-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.49-55
    • /
    • 2011
  • The failure of electronic instruments is mostly caused by heat and shock. This shock causes the crack initiation at the solder joint interface of PCB component which is closely related with the formation of intermetallic compound(IMC). The Ag content in Pb-free Sn-xAg-0.5Cu solder alloy used in this study was 1.0, 1.2 and 3.0 wt.%, respectively. After soldering with PCB component, isothermal aging was performed to 1000 hrs. The growth of IMC layer was observed during isothermal aging. The drop impact property of solder joint was evaluated by impact bending test method. The solder joint made with the solder containing lower Ag content showed better impact bending property compared with that with higher Ag content. On the contrary to this result, the solder joint made with solder containing higher Ag content showed better impact bending property after aging. It should be caused by the formation of fine $Ag_3Sn$, which relieved the impact. It showed consequently the different effect of fine $Ag_3Sn$ and coarse $Cu_6Sn_5$ particles formed in the IMC layer on the impact bending property.

Characterization of Porcine Tissue Perforation Using High-Power Near-Infrared Laser at 808-nm Wavelength (808 nm 파장의 고출력 근적외선 레이저 조사 시 돼지 조직의 천공 특성 연구)

  • Kim, Seongjun;Cho, Jiyong;Choi, Jaesoon;Lee, Don Haeng;Kim, Jung Kyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.807-814
    • /
    • 2013
  • A fundamental study on laser-tissue interaction was conducted with the aim of developing a therapeutic medical device that can remove lesions on the intestinal wall by irradiating a high-power 808-nm infrared laser light incorporated in an endoscopic system. The perforation depth was linearly increased in the range of 1~4 mm in proportional to laser output (3~12 W) and irradiation time (5~20 s). We demonstrated that the perforation depth during laser irradiation was varied according to the tissue property of each extracted porcine organ. The measurement of the temperature distribution suggests that the energy is localized in the irradiation spot and transferred to deep tissue, which protects the surrounding tissue from thermal injury. These results can be used to set the driving parameters for a laser incision technique as an alternative to conventional surgical interventions.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF