• Title/Summary/Keyword: 급수량

Search Result 355, Processing Time 0.12 seconds

Water Level Control of PWR Steam Generator using Knowledge Information and Neural Networks (지식정보와 신경회로망을 이용한 가압경수로 증기발생기 수위제어)

  • Bae, Hyeon-Bae;Woo, Young-Kwang;Kim, Sung-Shin;Jung, Kee-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.3
    • /
    • pp.322-327
    • /
    • 2003
  • The water level of a steam generator of pressurized light water nuclear Power generator is known as a subject whose control is difficult because of a shrinking and swelling effect that is been mutually contradictory in a variation of feed water. In this paper, a neural network model selects first coordinative controller by a inappropriate gain of two PI controllers and the selected controller's gain is tuned by a fuzzy self-tuner. Model inputs consist of the water level, the feed water, and the stream flow. One controller of both coupling controllers whose gain is handled firstly is decided based upon above data. The proposed method can analyze patterns of signals using the characteristic of neural networks and select one controller that needs to be tuned through the observed result in this paper. If one controller between both the water level controller and the feed water controller is selected by the neural network model then a gain of the PI controller is suitably tuned by the fuzzy self-tuner. Rules of the fuzzy self-tuner drew from the pattern of input and output data. In the summary, the goal of this Paper is to select the suitable controller and tune the control gain of the selected controller suitably through such two processes.

Effect of Water Quality Improvement due to Dam Discharge of Yeongsan River Watershed (영산강유역 댐 방류량에 의한 수질개선효과)

  • Park, Sung Chun;Oh, Chang Yeol;Kang, Kwon Soo;Gwak, Pil Jeong;Kim, Jeong Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.528-532
    • /
    • 2017
  • 영산강은 우리나라에서 호남평야 다음으로 넓은 나주평야에 농업용수를 공급하는 남도의 젖줄이며 영산강 유역민의 약 70%가 거주하는 약 150만의 광주광역시를 관통하는 우리나라 4대강의 하나이다. 그러나 영산강은 그 위상에 맞지 않게 우리나라 하천 중 수질이 가장 악화되어 있는 하천 중 하나이다. 영산강의 수질은 최근 10여 년 동안에 이루어진 수질오염총량관리제의 제 1단계(2004~2010년), 제 2단계(2011~2015년) 사업과 2012년 10월 광주광역시의 총인처리시설의 정상 가동, 영산강의 수질을 2급수(좋은 물) 목표로 4대강 사업의 일환으로 갈수기 유지유량 공급을 위하여 14개 농업용저수지의 둑 높이기 사업 등 배출오염부하량의 삭감노력과 하천유지유량의 증대계획 등으로 많이 개선되어 왔으나, 1~2급수를 유지하는 3대강 수준에 크게 못 미치는 3~4급수의 수질을 유지하며 상대적인 수질악화와 그 격차가 크게 차이를 보이며 고착화되고 있다. 따라서 본 연구에서는 4대강 사업의 일환으로 숭상이 이뤄졌고, 영산강의 수질에 비해 상대적으로 청수인 영산강유역의 4대호 담양댐, 광주댐, 장성댐, 나주댐의 호소수를 영산강에 추가로 방류할 경우 수질이 개선되는 정도를 분석하여 제시하였다. 수질개선효과를 분석하기 위하여 QUAL-MEV모델을 이용하여 영산강 수질모델을 구축하였고, 목표연도 2020년을 설정하여 4대호 방류구의 현재의 지리적 위치와 4대호의 수질자료를 모델에 직접 입력하여 추가 방류량의 변화에 따라 수질개선효과를 분석하여 그 문제점을 제시하였으며, 4대호 댐별로 영산강의 수질개선 기여도를 분석하여 제시하였다.

  • PDF

Development of air-conditioning and drinking water supply system using air-water heat pump (공기-물 히트펌프를 이용한 공조 및 음용수급수시스템 개발)

  • Paek, Yee;Kang, Sukwon;Jang, Jae-Kyung;Kim, Young-Hwa
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.118-118
    • /
    • 2017
  • 지구 온난화에 따른 환경변화로 인하여 최근 10년('02~'11)간 여름의 일수는 4일, 겨울 일수는 16일 각각 증가하였다. 현재 육계사 내의 고밀도 밀집사육으로 인하여 고온스트레스로 하절기 육계의 폐사율이 증가하고 있는 실정이다. 2016년 폭염으로 닭 406.1천수, 오리 15.7천수, 메추리 70천수, 돼지 8천수가 폐사하였다. 이에 혹서기 가축이 약430만수가 폐사하였으며 피해 보상금액 128억원 소요되었다. 본 연구에서는 하절기 고온스트레스 경감과 폐사율 저감을 위해 계사 냉난방 공조와 냉온 음용수 급수를 병행할 수 있는 고효율 환경 개선 시스템을 개발하여 고온스트레스 저감 및 생산성 향상에 목적이 있다. 계사 냉난방 공조 및 냉온음용수 급수 병행 시스템 설계요인을 분석하고 냉난방 공조부하, 냉온수 생산 부하를 고려한 시스템 용량 산정하고 히트펌프, 축열조, 냉난방 및 냉온수 분배장치 등 구성요소로서 공조 및 냉온음용수 급수시스템을 설치하였다. 시스템 용량은 공기-물 히트펌프(10kW,1대), 축열조(10톤), 음용수조(2톤), 열교환기(열교환량,5만kcal/h), 물순환펌프(250W,2대) 및 팬코일유닛(1만kcal/h,4대)으로 시스템 모니터링 및 제어 시스템 개발하여 계사 내 환경, 시스템 성능에 대한 실시간 모니터링을 통하여 저장하였다. 조사항목으로 위치별 온습도, 체중, 사료섭취량, 페사율 등을 조사 분석하였다. 연구결과 계사의 내부온도는 시험구에서는 평균 $25.3^{\circ}C$를 나타내었고 대조구에서는 평균 $28.1^{\circ}C$로서 $2.8^{\circ}C$ 높게 나타났으나 상대습도는 시험구 76.2%, 대조구 75.0%로 큰 차이가 없었다. 냉수급여에 따른 계사 높이별 내부온도는 상하의 온도차가 $4.5^{\circ}C$로 크게 차이가 났다. 육계의 음수량은 혹서기 냉수를 급여한 시험구에서 일일 23.2L, 대조구에서는 21.5L를 섭취하였다. 일일 사료섭취량은 냉수를 급여한 시험구에서 937g, 대조구에서는 725g을 섭취하였다. 사료섭취량은 냉수를 급여한 시험구가 212g 많이 섭취하였으며 사료요구율은 시험구는 1.86, 대조구는 1.91로서 시험구가 낮게 나타났다. 체중은 냉수를 급여한 시험구가 359g 많았으며 증체량은 냉수를 급여한 시험구에서 495g, 대조구에서는 392g으로 나타났다. 폐사율은 냉수를 급여한 시험구에서 84%가 폐사율을 줄일 수 있었다.

  • PDF

Evaluation method of Drought for Irrigation Reservoir (관개저수지의 가뭄평가 방법)

  • 김태철;이성희
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.75-80
    • /
    • 2002
  • The severity of drought in (the) irrigation reservoir could be evaluated by the accumulative rainfall method, soil moisture content method, storage ratio method, and water supply restricted intensity method, etc. The storage ratio method would be the most reliable one for irrigation reservoir. The pattern of drought might be forecast with the most similar pattern of accumulative rainfall and/or storage ratio out of the file of past operation history.

Drum Level Control in Thermal Power Plant (화력발전소의 드럼수위 제어)

  • Byun, S.H.;Park, D.Y.;Kim, B.C.;Shin, M.S.;Shin, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2163-2165
    • /
    • 2001
  • 화력 발전소 드럼수위의 제어는 보일러 시스템의 효율적인 운용을 위해 중요한 위치를 차지하고 있다. 드럼수위의 제어 목적은 드럼수위를 외란에 관계없이 항상 설정치로 유지하는 것이다. 정상 운전중에는 드럼의 중앙이하 부분에는 물이 차 있고, 상부에는 증기가 차 있으나 만일 수위가 너무 높아지면 carry over 현상이 발생하며 반대로 너무 낮으면 드럼 하부의 과열 및 튜브의 손상을 초래하여 대사고를 유발하게 되므로 드럼수위는 항상 정상으로 유지해야 한다. 드럼수위 제어루프는 처음에는 드림수위만을 제어입력으로 취하는 PI 제어기에 의해 이루어지다가, 주증기량이 일정량 이상 유지되면 드럼수위가 일정한 설정치를 유지하도록 급수량, 드럼수위, 주증기량에 의한 PI-PI 캐스케이드 형태의 제어로 절환되어 제어가 이루어진다. 또한 드럼 수위는 차압검출기에 의해서 측정되어지는데, 드럼의 압력에 따라 물과 증기의 밀도가 변하기 때문에 차압검출기에 의한 드럼수위 지시치는 드럼압력에 의한 보상도 요구되어진다. 본 논문에서는 중용량 화력발전소를 대상으로 드럼수위 보상과 드럼수위 제어기를 구현하고, 적용하여 실제 발전출력 증발시의 드럼수위 제어결과를 보임으로서 구현한 드럼수위 제어기의 효용성을 보인다.

  • PDF

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

Implementation of Daily Water Supply Prediction System by Artificial Intelligence Models (일급수량 예측을 위한 인공지능모형 구축)

  • Yeon, In-sung;Jun, Kye-won;Yun, Seok-whan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.395-403
    • /
    • 2005
  • It is very important to forecast water supply for reasonal operation and management of water utilities. In this paper, water supply forecasting models using artificial intelligence are developed. Artificial intelligence models shows better results by using Temperature(t), water supply discharge (t-1) and water supply discharge (t-2), which are expressed by neural network(LMNNWS; Levenberg-Marquardt Neural Network for Water Supply, MDNNWS; MoDular Neural Network for Water Supply) and neuro fuzzy(ANASWS; Adaptive Neuro-Fuzzy Inference Systems for Water Supply). ANFISWS model which is applied for water supply forecasting shows stable application to the variable water supply data. As results, MDNNWS model shows the highest overall accuracy among proposed water supply forecasting models and the lowest estimation error with the order of ANFISWS, LMNNWS model.

A Study on the Quantity of Using Water in APT for Estimating the Reasionable amount of Water Supplied (아파트에서 적정 급수량 산정을 위한 사용수량에 관한 조사 연구)

  • ChangHuanAn
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.85-90
    • /
    • 1994
  • Using water in each apartment is influnced by several facters including the income level of inhabitants, the manner of life, the area apartments and climate. The automization of santory machines or facilites in recently bulit apartements has caused largely increases in amount of water use. Therefore the design for water supply is very important for the maintenance of the optimum level or pressure of water supply. This study is based on the offer of basic data for improving the quality of water supply and imploying the sanitory machine or sanitory facilites by analysis of amount increased of water use rapidly. The quantity of hot and cold water use by year is examined as a factor of construction in apartment.

  • PDF

Optimal Flood Control Volume in the Irrigation Reservoir (관개저수지의 적정 홍수조절용량 설정방법)

  • 김태철;문종필;민진우;이훈구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.81-91
    • /
    • 1998
  • Water level of irrigation reservoir during the flood season could be kept to a certain level, so called, flood control level by releasing the flood inflow in advance in order to reduce the peak discharge of next coming flood and the damage of inundation. Concept of restriction intensity of water supply was introduced to evaluate the influence of flood control volume on the irrigation water supply. Restriction intensity can be calculated by multiplying the ratio of restriction to the days of restriction which are obtained from the operation rule curve and daily water level of irrigation reservoir and it has the dimension of % day. The method of restriction intensity was applied to the Yedang irrigation reservoir with the observed data of 30 years to review whether the present flood control volume is reasonable or not, and suggest the optimal flood control volume, if possible.

  • PDF

Conceptual Design of the Minimum Integration IGCC (최소 공정연계를 가지는 석탄가스화 복합발전 시스템의 개념 설계)

  • Park, Moung-Ho;Kim, Jong-jin;Kim, Yong-Hee;Kim, Chul
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • 공정연계를 최소호하는 IGCC 시스템에 대한 개념설계를 수행하였다. 공정분석은 상용코드인 ASPEN PLUS를 이용하였다. 가스화기의 적절한 운전조건을 찾기위하여 가스화기를 경계조건으로 하는 액서지 민감도분석을 통하여 투입되는 슬러리와 산소의 조건을 결정하였다. 또한 , 생성가스 냉각시 현열을 최대한 회수학 ldn하여 , 열교환망을 통하여 급수를 에열하고 가스화플랜트의 각 부분에 공급하도록 공정을 구성하였다. 여분의 가열된 급수는 갑압증발시켜 복합사이클에서 동력을 생성시키는데 사용되어진다. 이와 같은 시스템은 , 가스터빈 -ASU-가스화플랜트의 공기에 의한 공정연계와, HRSG-가스냉각 및 정제시스템 간의 증기연계를 가능한 적게함으로써 공정의 운전성과 경제성을 최적으로 유지할 수 있다. 본 연구에서 제시하는 공정의 경우에, 열효율이 약 39%(고위발열량 기준)으로 나타났으며, 단위 기기 및 단위공정들의 최적화를 통하여 40%의 효율달성이 가능할 것이다.

  • PDF