• Title/Summary/Keyword: 급내상관계수

Search Result 40, Processing Time 0.023 seconds

Study of Validity and Interrater Reliability of Korean Version of the Peabody Developmental Motor Scale 2 (한글판 Peabody Developmental Motor Scale 2의 타당도와 검사자간 신뢰도 연구)

  • Lee, Ji-Ho;Kim, Kyeong-Mi;Chang, Moon-Young;Hong, Eunkyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.17 no.3
    • /
    • pp.14-25
    • /
    • 2019
  • Objective : This study aims to verify the content validity and inter-rater reliability of the Korean version of the Peabody Developmental Motor Scale 2 (PDMS-2) and to identify the concurrent validity by comparing it with the Korean version of the Bruininks-Oseretsky Test of Motor Proficiency-2 (BOT-2). Methods : PDMS-2 was translated by the researcher and an eighth-year clinical occupational therapist. The content consistency of the Korean version of the PDMS-2 was verified by three professors with experience using it. After the verification of the content consistency of the PDMS-2 by the five clinical occupational therapists and the additional revision, the Korean version of the PDMS-2 was completed. The researcher and another occupational therapist evaluated the Korean version of PDMS-2 in 50 children and measured the inter-rater reliability. Concurrent validity was measured by comparing the results of the Korean version of PDMS-2 and Korean version of BOT-2. Results : The content consistency test showed overall agreement of mean 3.45, and the content understanding test showed a high level of understanding of mean 3.69. The inter-rater reliability and concurrent validity of the Korean version of the PDMS-2 showed a statistically significant correlation. Conclusion : The Korean version of the PDMS-2 showed high content understanding, reliability, and validity. It can assist clinicians and researchers who work in fields related to child treatment or development.

Reliability of a Questionnaire for Evaluation of Dry Mouth Symptoms (구강건조증 증상 평가를 위한 설문지의 신뢰도에 관한 연구)

  • Lee, Jeong-Yun;Lee, Young-Ok;Kho, Hong-Seop
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.383-389
    • /
    • 2005
  • Xerostomia is defined as a subjective complaint of dry mouth that may be perceived when there is insufficient mucosal wetting. However, the diagnosis and treatment of xerostomia is not that simple because of the fact that the subjective awareness of dry mouth is not always correlated with a diminution in the flow of saliva and there is always a difference between individuals in salivary flow rates needed for normal oral function. In the present study, the aim was to develop a questionnaire to evaluate the dry mouth symptoms and to analyze its reliability and usability as a diagnostic and analytic tool for xerostomia. The questionnaire which consists of 6 Visual Analogue Scale(VAS) type questions to evaluate the subjective oral dryness and 4 questions to evaluate behavior to avoid oral dryness was developed and administered twice with 1 week's interval to the healthy 88 young adults without dry mouth symptoms(44 males and 44 females; mean age was $25.6{\pm}3.1$ years in male and $24.3{\pm}2.1$ years in female). The results were as follows. 1 The intraclass correlation coefficients of 6 questions to evaluate the subjective oral dryness were as significantly high as 0.767 for the degree of oral dryness at other times of the day, 0.850 for the amount of saliva in the mouth, and 0.791 for the degree of effect on daily life due to oral dryness and as high as 0.563 for the degree of oral dryness at night or on awakening, 0.674 for the degree of oral dryness during eating, and 0.641 for the degree of difficulty in swallowing foods. 2. Cronbach's alpha value of 6 questions was 0.982. It can be concluded that the series of questions to evaluate the subjective oral dryness has high internal consistency. 3. Cohen's kappa values of 4 questions to evaluate behavior to relieve oral dryness were as significantly high as 0.850 for the frequency of keeping a glass of water at the bedside and as high as 0.506 the frequency of awakening during sleeping due to oral dryness, 0.419 for the frequency of sipping liquids to aid in eating dry foods, and 0.407 for the frequency of using a candy or chewing gum due to oral dryness. From the results, it can be concluded that the questionnaire consisting of 6 VAS type questions to evaluate the subjective oral dryness and 4 questions to evaluate behavior to relieve oral dryness has reliability of good to excellent level, and that the series of 6 VAS type questions has significantly high internal consistency to evaluate the subjective oral dryness.

Variability of Transrectal Shear Wave Elastography in a Phantom Model (팬텀연구에서 경직장 전단파탄성초음파의 가변성)

  • Jihyun Lee;Seong Kuk Yoon;Jin Han Cho;Hee Jin Kwon;Dong Won Kim;Jun Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1110-1122
    • /
    • 2023
  • Purpose This study aimed to assess the variability of transrectal shear wave elastography (SWE) using a designed phantom. Materials and Methods In a phantom, the SWE values were examined by two radiologists using agarose and emulsion silicone of different sizes (1, 2, and 3 cm) and shapes (round, cubic) at three depths (1, 2, and 3 cm), two region of interest (ROI) and locations (central, peripheral) using two ultrasound machines (A, B from different vendors). Variability was evaluated using the coefficient of variation (CV). Results The CVs decreased with increasing phantom size. Significant changes in SWE values included; agarose phantom at 3 cm depth (p < 0.001; machine A), 1 cm depth (p = 0.01; machine B), emulsion silicone at 2 cm depth (p = 0.047, p = 0.020; both machines). The CVs increased with increasing depth. Significant changes in SWE values included; 1 cm agarose (p = 0.037, p = 0.021; both machines) and 2 cm agarose phantom (p = 0.047; machine A). Significant differences in SWE values were observed between the shapes for emulsion silicone phantom (p = 0.032; machines A) and between ROI locations on machine B (p ≤ 0.001). The SWE values differed significantly between the two machines (p < 0.05). The intra-/inter-operator agreements were excellent (intraclass correlation coefficient > 0.9). Conclusion The phantom size, depth, and different machines affected the variability of transrectal SWE.

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.

Validity of Arch Relationship Measurements in Digital Dental Models (디지털 치열 모형에서 악궁 관계 지표 측정의 타당성)

  • Ryu, Jiin;Yang, ByoungEun;Lee, Hyelim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.14-24
    • /
    • 2022
  • The aim of the present study is to evaluate the validity of orthodontic measurements including tooth width, Bolton ratio, overjet and overbite on the digital dental models. Dental models of the subjects aged 12 to 18 were obtained in 3 different forms, which were conventional stone model, digital model created with Freedom HD model scanner, and digital model produced with CS3600 intraoral scanner. After measurements were made on the models, reliability and reproducibility of the measurements were evaluated by using intraclass correlation coefficient, while validity was assessed with paired t-test. As a result, significant reliability and reproducibility were verified, with intraclass correlation coefficient exceeding 0.750 in all groups. Measurements of the model scanned group showed an adequate validity in overall and anterior Bolton ratio, overjet, and overbite. Intraoral scanned models showed an adequate validity in anterior Bolton ratio, and overjet. Measurement on intraoral scanned digital models can be considered as an alternative for young children who have difficulty in taking impression. Furthermore, careful considerations on measurement error should be made in clinical situations.

Reliability of static balance abilities measure using a smartphone's acceleration sensor (스마트폰의 가속도 센서를 이용한 정적균형능력 측정의 신뢰도 연구)

  • Han, Seul-Ki;Lee, In-Hak;Park, Nu-Ri
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.233-238
    • /
    • 2016
  • The purpose of this study is to investigate the reliability of static balance measurements using a smartphone. Thirty subjects were selected among university students who had no fractures, history of operation, or inflammatory arthritis, and they had not started regular exercise during the past three months. The smartphone used in this study was a Galaxy S5LTE (SM-G900F, Samsung, Korea, 2014), and the application was a Sensor Kinetics Pro (Ver. 2.1.2, INNOVENTIONS Inc., US, 2015). Static balance ability was measured three times at one-day intervals between tests and retests. The first and second measurements used the same process. Analysis was done using the Wilcoxon signed rank test and intraclass correlation coefficient (ICC (2,1)). The results were as follows. With eyes opened, there was no significant difference (p>0.05), a high volume of correlation (r>0.75, p<0.05), and very high reliability (ICC>0.80) between the first measurement and second measurement. With eyes closed, there was also no significant difference (p>0.05), a high volume of correlation (r>0.75, p<0.05), and very high reliability (ICC>0.80) between the measurements. The results show that the smartphone is likely accurate for measuring static balance. This study will look forward to being the only basis for measuring future application development and the ability to balance.

Effect of forearm length applied on empirical models of maximum endurance time during isometric elbow flexion (등척성 팔굽 굽힘시 최대근지구력시간의 실증적 모델에 적용한 전완길이의 영향)

  • Sang-Sik Lee;Kiyoung Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.338-346
    • /
    • 2023
  • During isometric elbow flexion, forearm length should be an important factor to determine not only joint torque but also maximum endurance time (MET), when the forearm is perpendicular to the direction of the force. The purpose of this paper is to examine the effect of forearm length as an additional factor on empirical models of MET such as an exponential model and a power model during isometric elbow flexion. Thirty volunteers participated in our experiment to measure factor variables such as circumferences and lengths of their upper and lower arms. Their METs were measured according to the percent of maximum voluntary contraction intensity (%MVC). For the multiple linear regression model of ln(MET) using these measurements, significant variables could be observed in %MVC and forearm lengths (P<0.05). The empirical models were assessed by these models using forearm length as the additional factor. Mean absolute deviations (MAD) between the measured METs amd the two empirical models were about 19.4 [s], but MAD using models applied forearm lengths were reduced to about 16.2 [s]. The correlation coefficients and intraclass correlation coefficients were about 0.87, but those applied forearm lengths were increased to about 0.91. These results demonstrated that forearm length was a significant additional factor to the empirical model.

Effectiveness of Disposable Single Electrocardiogram Electrode (SIM-Tree) Comparing with Conventional Method (일회용 단일 심전도패드(SIM-Tree)의 기존 방법과 비교를 통한 효과 분석)

  • Kim, Hye-Sun;Choi, Hyo-Jeong;Kim, Ho-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.435-440
    • /
    • 2018
  • This study was conducted to compare the effectiveness of the newly developed electrode pad of ECG with that of a conventional method. To accomplish this, participants who performed both methods on a 46 year old male model were queried and their satisfaction, time, and accuracy were measured by a specialist from 01/06/2018 to 15/06/2018. In the conventional method, a newly developed single pad employing a 12-lead ECG and SIM-Tree was employed. There were 104 total participants in this study (44% medical members). Evaluation of the total procedure time revealed that SIM (mean 65.39 seconds) was more rapid than C (mean 94.38 seconds) (p<0.05). When we evaluated the response after all process, satisfaction with SIM (mean 97.69 seconds) was greater than that with C (mean 68.5 seconds) (p<0.05). Moreover, the intra-class correlation coefficient (ICC) was 0.959 and accuracy was very high (p<0.05). In conclusion, the SIM-Tree was very effective based on procedure time, satisfaction and accuracy when compared with conventional methods.

Reliability of Web and Paper-Based Survey Methods for Mibyeong and Cold-Heat Pattern Questionnaire for Korean Medicine Health Assessment: Pilot Study (한의 건강 측정을 위한 미병과 한열설문의 웹과 종이 기반 조사 방법의 신뢰도: 예비연구)

  • Jeong, Kyoungsik;Kim, Hoseok;Lee, Siwoo;Lim, Sueun;Baek, Younghwa
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.8
    • /
    • pp.671-680
    • /
    • 2022
  • This study evaluated the consistency between the web-based and paper-based mibyeong and cold-heat pattern questionnaire, the Korean medicine-based tool for diagnosing and classifying health status. First, a web-based survey was conducted on 72 ordinary people; subsequently, a paper-based survey was conducted after a certain time interval. The equivalence between the web-based and paper-based surveys was evaluated on the basis of the consistency between scores using the Intraclass Correlation Coefficient (ICC) and Bland-Altman methodology. The mibyeong questionnaire showed high reliability for the web-based and paper-based surveys (ICC=0.95, 95% CI 0.92 - 0.97), and the cold-heat pattern questionnaire showed high reliability for both cold syndrome (ICC=0.98, 95% CI 0.96 - 0.99) and heat syndrome (ICC=0.9, 95% CI 0.83 - 0.93). The difference in average scores between the two survey methods was -0.25 for the mibyeong survey, -0.17 for the cold syndrome, and 0.11 for the heat syndrome, showing a similar pattern. Among the respondents, 84% showed positive satisfaction with the web-based survey, and 80% preferred the web-based survey. Overall, this study confirmed the reliability and feasibility of the web-based survey methods for the mibyeong and cold-heat pattern questionnaire. This could be a useful tool for the follow-up of subjects in long-term cohort studies.

Analysis of Tissue Equivalent Characteristics of Agar Phantom for Hyperthermia Therapy (온열종양치료 한천 팬텀의 조직등가 특성 분석)

  • Jeong-Geun Park;Kyeong-Hwan Jeong;Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.985-991
    • /
    • 2023
  • A tissue-equivalent phantom is necessary for quality control of hyperthermia therapy. However, since there is no phantom for this purpose, phantoms made from agar are being used in various studies. The tissue-equivalent properties of the agar phantom were confirmed by comparison with the tissue-equivalent material bolus in this study. CT images of the agar phantom and bolus were acquired, and tissue equivalent characteristics were analyzed with image analysis and dose calculation using a computerized radiation therapy planning system. The average pixel value was 96.960±10.999 in bolus, 108.559±8.233 in 3% agar phantom, and 111.844±8.651 in 4% agar phantom. Using the SSD technique, 100 cGy was prescribed at a depth of 1.5 cm and 6 MV X -ray was set to irradiated to 10x10 cm2, and the absorbed dose according to depth was calculated from the central axis of the beam. The intraclass correlation coefficient of dose distribution of bolus, 3% agar phantom, and 4% agar phantom was 0.979 (p<.001, 95%CI .957-.991). The density (g/cm3) at the point where the absorbed dose was calculated was 0.990±0.020 at the bolus, 1.018±0.020 at the 3% agar phantom, and 1.035±0.024 at the 4% agar phantom. In this study, the internal density distribution and uniformity of the agar phantom were confirmed to be appropriate as a tissue equivalent material by analysis of CT images and a computerized radiation therapy planning system.