• Title/Summary/Keyword: 금속화

Search Result 2,191, Processing Time 0.031 seconds

Image Processing for 3-D Shape Estimation of Specular Reflection (경면반사체의 3차원 형상 추정을 위한 영상처리)

  • Kim, Jee-Hong;Cho, Byung-Gwon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • A method to estimate the 3-D shape of surface with specular reflection is proposed, where the difference between the images reflected from a flat surface and a curved surface is used. First, we analyzed the geometry of the spatial reflection at specular surface and the variation of reflected light due to curved surface, whose results are used to estimate 3-D shape. The proposed method is shown to be effective via experiments using the illumination with spatially distributed light source and the CCD camera to capture the light reflected from a surface. In experiments, the captured images from curved surface with specular reflection are processed to approximately estimate 3-D shape.

Development of Fire-Diagnosis Concrete using Composite Sensors (복합센서를 이용한 화재자현 콘크리트의 개발)

  • Choi, Young-Wha;Kim, Ie-Sung;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 2010
  • Use of concrete has undoubtedly become widespread in construction and civil engineering. Sensors are used to add functional characteristics to concrete. Self-diagnosis concrete is also being developed. The thermal protector used in the study is a sensor using the linear expansion and cubical expansion of metal. The LED(Light Emitting Diode) is a phototransistor type, and to secure high-sensitivity light, the prices of these sensors are low. Rising temperatures of concrete elements can be predicted from LED of the external virtual beam due to operation of thermal protector sensors of concrete beam caused by fire load on the concrete specimen. In this study, the development of fire-diagnosis concrete using composite sensors are the fundamental study for damage detection using simply measurements.

  • PDF

Effects of Ce Addition and Isothermal Aging on the Elevated Temperature Tensile Properties of Mechanically Alloyed Al-Ti Alloys (기계적합금화한 Al-Ti 합금의 고온 인장 특성에 미치는 Ce의 첨가와 등온열처리의영향)

  • Kim, Jun-Gi;O, Yeong-Min;Kim, Yong-Deok;Kim, Byeong-Cheol;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.7 no.5
    • /
    • pp.444-450
    • /
    • 1997
  • 기계적합금화 한 AI-Ti합금의 상온 및 고온 인장강도는 25at.% Ti을 Ce으로 치환함에 따라 증가하였다. 그러나 25at.% 이상의 Ce첨가는 합금의 인장강도를 감소시켰다. 이는 Ce이 적은 고용도 효과에 의해 금속간화합물의 초대화를 억제하여 합금의 강도를 증가시키지만 다량 첨가시에는 Ti에 비해 무거운 원자량으로 인해 분산상의 부피분율을 감소시켜 합금의 강도가 오히려 저하시킨 것으로 생각된다. Ce의 첨가는 40$0^{\circ}C$와 51$0^{\circ}C$에서 합금의 열저안정성을 향상시키는 것으로 나타났다. 300-51$0^{\circ}C$ 온도범위에서 측정된 AI-8wt.%(Ti+Ce)합금의 변형에 필요한 활성화에너지는 AI의 자기확산에 필요한 에너지 (142kJ/mode)의 1.3-1.9배로 나타났다. 이로부터 AI-Ti-Ce 합금의 고온 변형은 Orowan기구에 의한 것을 생각된다.

  • PDF

A Study on the Development of Electrophotographic Photoreceptor by Dye Sensitized System (II) (색소증감에 따른 전자사진 감광체 개발에 관한 연구)

  • Jeong, Eun-Sil;Jeong, Pyeong-Jin
    • Korean Journal of Materials Research
    • /
    • v.7 no.5
    • /
    • pp.403-410
    • /
    • 1997
  • 본 연구는기존의 보고에서 보다 감광화효율을 더욱 향상시키기 위하여 결정형이 다른 전하발생물질 (CGM:Charge Generation Material)과 전하수송물질(CTM:Charge Transport Material)을 사용하여 감광체를 만들었고, 이들의 정전특성을 비교검토하였다. 전하발생물질로서 결정형이 다른 $\alpha$-, $\beta$-, x-형 무금속 프탈로시아닌 (H$_{2}$Pc)을 사용한 결과, x-H$_{2}$Pc를 사용한 감광체의 감도는 E$_{1}$2/의 값이 2.62 $\mu$J/$\textrm{cm}^2$로 가장 두수하게 나타났다. 전하발생층(CGL:Charge Generation Layer)에 첨가되는 CGM-CTM, CGM-CTM-ZnO로 구성된 감광체보다 전하발생층에 전하발생계만으로 구성된 감광체의 경우의 전하유지율 (80%) 및 감도(E$_{1}$2/=2.83$\mu$J/$\textrm{cm}^2$)면에서 우수함을 보여주었다. 한편 binder로서 PVB-co-PVA-co-PVA$_{c}$[poly(viny1 butyral-co-viny1 alcohol-co-viny1 acetate)]를 사용했을 때는, CGM-CTM으로 구성된 감광체보다 CGL에 CGM-CTM으로 구성된 감광체의 경우의 전하유지율(71%) 및 감도(E$_{1}$2/=2.62$\mu$J/$\textrm{cm}^2$)면에서 우수함을 보여주었다.

  • PDF

The Potentiometric Performances of Membrane Electrodes Based on Tetracycline Antibiotics (테트라싸이크린 항생제를 담체로 이용한 막전극의 전위차 특성)

  • Baek, Jong-Gyu;Rhee, In-Sook;Paeng, Ki-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.3
    • /
    • pp.132-134
    • /
    • 2006
  • The main component governing selectivity in ion-selective electrodes and optodes is the ionophore. For this reason, a member of natural products that possess selective ion-binding properties have long been sought after. By applying this principle, the performance of tetracycline used as neutral carriers for cation selective polymeric membrane electrode was investigated. The cation ion-selective electrode based on tetracycline gave a good Nernstian response of 26.6 mV per decade for calcium ion in the activity range $1x10^{-6}M$ to $1x10^{-2}M$ with and without lipophilic additives. The optimized cation ion-selective membrane electrodes displayed very comparable potentiometric responses to various mono and di-valent cations of alkali and alkaline earth metal ions except $Mg^{2+}$.

Improvement of Switch Box Manufacturing Process and Development of Handling Mechanism (스위치박스 제조공정 개선과 핸들링 장치 개발)

  • 김세환;이은종;김현효;유정봉
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2003
  • Switch box is metal box and used for electric wire pipe in building. In manufacturing switch box, we need 5∼6 press machines, 5∼6 dies, 1 tapping machine. and 7∼8 operators. What matters is rise of manufacturing cost and operators' reluctance of working. To solve this problem, we modified the pre-existing die and developed handling mechanism, which leads to improve the manufacturing process. After the research and development, we could reduce the number of machines and workers needed in the process; 2 press machines, 2 dies, 1 tapping machine, and 1 operator. That means we can save labor and the number of operators needed, reduce manufacturing cost, and get the effect of import replacement.

  • PDF

Study on Metalizing 2% Na-PbTe for Thermoelectric Device (고효율 열전소재 2%Na-PbTe 의 소자화에 관한 연구)

  • Kim, Hoon;Kang, Chanyoung;Hwang, Junphil;Kim, Woochul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.2
    • /
    • pp.32-38
    • /
    • 2014
  • Heat emission from the laser diode used in the optical disc drive and the defects from the increased temperature at the system have attracted attentions from the field of the information storage device. Thermoelectric refrigerator is one of the fine solutions to solve these thermal problems. The refrigeration performance of thermoelectric device is dependent on the thermoelectric material's figure-of-merit. Meanwhile, high electrical contact resistivity between metal electrode and p- and n-type thermoelectric materials in the device would lead increased total electrical resistance resulting in the degeneracy in performance. This paper represents the manufacturing process of the PbTe-based material which has one of the highest figure-of-merit at medium-high-temperature, ~ 600K to 900 K, and the nickel contact layer for reduced electrical contact resistance at once, and the results showing the decent contact structure and figure-of-merit even after the long-term operation environment.

A study on Real-time Graphic User Interface for Hidden Target Segmentation (은닉표적의 분할을 위한 실시간 Graphic User Interface 구현에 관한 연구)

  • Yeom, Seokwon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.2
    • /
    • pp.67-70
    • /
    • 2016
  • This paper discusses a graphic user interface(GUI) for the concealed target segmentation. The human subject hiding a metal gun is captured by the passive millimeter wave(MMW) imaging system. The imaging system operates on the regime of 8 mm wavelength. The MMW image is analyzed by the multi-level segmentation to segment and identify a concealed weapon under clothing. The histogram of the passive MMW image is modeled with the Gaussian mixture distribution. LBG vector quantization(VQ) and expectation and maximization(EM) algorithms are sequentially applied to segment the body and the object area. In the experiment, the GUI is implemented by the MFC(Microsoft Foundation Class) and the OpenCV(Computer Vision) libraries and tested in real-time showing the efficiency of the system.

Fabrication of Composite Powders by Mechanical Alloying of Magnetite-M (M = Ti, Al) Systems (마그네타이트와 금속(Ti, Al)의 기계적 합금화에 의한 복합분말의 합성)

  • 홍대석;이성희;이충효;김지순;권영순
    • Journal of Powder Materials
    • /
    • v.11 no.3
    • /
    • pp.247-252
    • /
    • 2004
  • Recently, it has been found that mechanical alloying (MA) facilitates the nanocomposites formation of metal-metal oxide systems through solid-state reduction during ball milling. In this work, we studied the MA effect of Fe$_{3}$O$_{4}$-M (M = Al, Ti) systems, where pure metals are used as reducing agents. It is found that composite powders in which $Al_{2}$O$_{3}$ and TiO$_{2}$ are dispersed in $\alpha$-Fe matrix with nano-sized grains are obtained by mechanical alloying of Fe$_{3}$O$_{4}$ with Al and Ti for 25 and 75 hours, respectively. It is suggested that the large negative heat associated with the chemical reduction of magnetite by aluminum is responsible for the shorter MA time for composite powder formation in Fe$_{3}$O$_{4}$-Al system. X-ray diffraction results show that the reduction of magnetite by Al and Ti if a relatively simple reaction, involving one intermediate phase of FeAl$_{2}$O$_{4}$ or Fe$_{3}$Ti$_{3}$O$_{10}$. The average grain size of $\alpha$-Fe in Fe-TiO$_{2}$ composite powders is in the range of 30 nm. From magnetic measurement, we can also obtain indirect information about the details of the solid-state reduction process during MA.

Determination of Arsenic in Korean human liver and manganese, copper in Vitamin prepartions by neutron action analysis (중성자(中性子) 방사화(放射化) 분석법(分析法)에 의(依)한 한국인(韓國人) 간장중(肝臟中)의 비소(砒素) 및 Vitamin제제중(製劑中)의 금속(金屬)(CU, Mn)의 정량(定量))

  • Oh, Soo-Chang
    • Journal of Pharmaceutical Investigation
    • /
    • v.4 no.4
    • /
    • pp.17-25
    • /
    • 1974
  • 1. Neutron acivation analysis of arsenic contained in Korean human liver was studied in the view point of forensic chemistry, using 12 corpses. A sample of 1g was irradiated for 30 mins. in a neutron flux of $1.2{\times}10^{12}n/cm^2/sec$, followed by nitric-sulfuric acid digestion and then by Gutzeit separation. Radio activity was detected by it's scintillation counter. The arsenic content in the liver was found to be $0.01{\mu}g/g$ to $0.15{\mu}g/g$. 2. A rapid and convenient method for the radiochemical determination of minerals by neutron activation analysis was established. After neutron irradiation to the standard soln. of Cu and Mn in pneumatic tube (neutron flux : $1.2{\times}10^{12}n/cm^2/sec$), Cu and Mn were determined by estimating the ratio of the widths under energy peak area in ${\gamma}-ray-spectrogram$. When the standard soln. of Mn and Cu is irradiated for 15 mins. to 18 hrs., recovery test shows that the relative errors are 5.1% and 4.5% for copper and manganese, respectively.

  • PDF