• Title/Summary/Keyword: 금속정

Search Result 817, Processing Time 0.035 seconds

Arthrodesis of the Knee Using a Retrograde Femoral Intramedullary Nail: Technical Report (역행성 대퇴부 골수강 내 금속정을 이용한 슬관절 고정술: 술기 보고)

  • Wang, Lih;Kim, Sun Hyo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.183-189
    • /
    • 2021
  • Arthrodesis is one of the last options available to obtain a stable, painless knee in patients who are unable to undergo reconstructive surgery due to a damaged knee joint. A variety of techniques have been used, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Another option is the use of a short nail such as the Neff nail, the Wichita nail, or the Huckstep nail, but there are no commercial short nails available for use in Korea. This technical report describes a technique for knee arthrodesis using a retrograde femoral intramedullary nail.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Factors Affecting the Period of Bone Union When Treating Femoral Fractures with a Retrograde Intramedullary Nail (역행성 골수강 내 금속정을 이용한 대퇴골절의 치료 시 골유합 기간에 영향 미치는 인자)

  • Kim, Bum-Soo;Kim, Seong-Tae;Shin, Seungyup;Jeon, Seong Man
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.326-333
    • /
    • 2021
  • Purpose: A retrograde intramedullary nail is commonly used to treat femoral shaft and distal femur fractures. The authors analyzed the treatment results and the factors affecting the period of bone union for thirty-five patients treated with a retrograde intramedullary nail. Materials and Methods: Thirty-five patients who could be followed up for more than twelve months after the treatment with retrograde intramedullary nailing were analyzed retrospectively. The treatment results and the relationship between the period of bone union and the patient's age, sex, comminution of fracture, presence of open fracture, location of the fracture, and accompanying fractures were evaluated. Results: The average bone union time was 4.50 months. The period of bone union was unaffected by the age, sex, location, and presence of open fractures but was affected by the presence of comminution and accompanying fractures. Conclusion: Retrograde intramedullary nailing is effective for distal and shaft of fractures of the femur. The period of bone union is affected by the presence of comminution and accompanying fractures.

Antegrade Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술)

  • Cho, Chul-Hyun;Song, Kwang-Soon;Kim, Sin-Ki
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: To evaluate the results and complications of antegrade intramedullary interlocking nailing in humerus shaft fractures. Materials and Methods: We evaluated the clinical outcomes, radiologic results and complications in 47 patients with humerus shaft fracture treated with antegrade intramedullary interlocking nailing, and followed up until bony union. Bony union was confirmed by serial plain radiographs and the clinical outcomes were assessed according to the ASES scoring system. Results: Bony union was confirmed in 41 (87.2%) out of a total 47 patients, and the mean union period was 14.5 weeks. Major complications were as follows: 6 non-union, 3 delayed union, 2 intraoperative posterior cortex fracture in the distal humerus and 2 permanent shoulder pain, including 1 case of adhesive capsulitis. The clinical outcomes were as follows: 29 excellent, 11 good, 4 fair and 3 poor. Satisfactory outcomes were demonstrated in 40 patients (85.1%). Conclusion: Anterograde intramedullary interlocking nailing as treatment for humerus shaft fracture showed satisfactory bony union and clinical outcomes. It is considered an efficacious treatment, especially in patients with associated injury, such as multiple fractures and segmental fracture.

Clinical and Radiographical Follow-up for Residual Displacement of Fracture Fragments after Interlocking Intramedullary Nailing in Humeral Shaft Fractures (상완골 간부 골절에서 교합성 골수강 내 금속정 고정 후 잔존한 골절편 전위에 대한 임상적, 방사선학적 추시)

  • Yum, Jae-Kwang;Lim, Dong-Ju;Jung, Eui-Yub;Sohn, Su-Een
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.107-114
    • /
    • 2013
  • Purpose: This study is designed to evaluate the clinical and radiographical results for the displacement of fracture fragments after interlocking intramedullary nailing in humeral shaft fractures. Materials and Methods: We retrospectively reviewed the results of 8 cases of humeral shaft fractures that have displacements of over 10 mm and under 20 mm after interlocking intramedullary nailing between July 2004 and August 2011. The mean age was 54.1 years (range, 43 to 70 years) and there were 3 male and 5 female patients. Radiographically, the time to bony union, change of displacement and angulation of the fracture site, and degree of improvement of these two factors were measured. Clinically, the range of motion of shoulder and elbow joints, postoperative pain and complications were evaluated. Results: All cases showed complete bony union in last follow-up. The mean time to bony union was 16.1 weeks. At the last follow-up, almost all cases had normal range of motion of shoulder and elbow joints. But, one case had stiffness of shoulder joint. Therefore, arthroscopic capsular release and manipulation was performed. One case had transient shoulder pain and the other case had transient elbow pain. In the two cases, pull-out of proximal interlocking screw were noted, but they finally had bony union. Conclusion: Although considerable displacement of fracture fragments after interlocking intramedullary nailing in humeral shaft fractures was present, we had excellent radiographical and clinical outcomes. Therefore, an additional procedure, such as open reduction or another fixation for the fracture site, was not necessary.

Frictional resistance of different ceramic brackets and their relationship to the second order angulation between bracket slot and wire (세라믹 브라켓의 종류 및 브라켓 슬롯과 와이어 각도에 따른 마찰 저항 차이)

  • Choi, Yoon-Jeong;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.207-217
    • /
    • 2006
  • Although ceramic brackets have been used widely for improved esthetics during treatment, ceramic brackets have some inherent problems; brittleness, attrition of the opposing teeth and high frictional resistance. This study was performed to understand the frictional resistance of the ceramic brackets, as well as to be a helpful reference for finding the solutions to the problem of frictional resistance. Three different kinds of brackets were used; metal bracket, polycrystalline ceramic brackets with a metal slot to reduce the high frictional resistance and monocrystalline ceramic brackets. The brackets were tested with a $.019{\times}.025$ stainless steel wire with a second order angulation of $0^{\circ}\;and\;10^{\circ}$, and the static and kinetic frictional forces were measured on the universal testing machine. The results of this study showed that the ceramic brackets, especially the monocrystalline ceramic bracket without a metal slot, generated higher frictional resistance than the metal bracket, and the frictional resistance was increased as the angulation between the bracket slot and the wire increased. Therefore, the development of the ceramic bracket with reduced frictional resistance and the prevention of excessive crown tipping during orthodontic treatment will lead to the simultaneous attainment of more efficient and improved esthetic treatment goals.

금속 게이트 전극으로의 활용을 위한 이중 금속층의 전기적 특성 연구

  • Jeong, Eun-Jae;Yang, In-Seok;Go, Dae-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.161-161
    • /
    • 2007
  • 금속 게이트 전극으로 활용하기 위해서 두 가지의 금속박막으로 구성된 이중 금속층을 D.C. Magnetron sputtering 방식으로 증착하여 MOSCAP을 제작하였다. 박막의 적층 구조 및 열처리에 따른 계면반응을 AES, XPS를 통해 분석하였고, XRD 측정을 통해 결정상을 분석하였다. 또한 박막의 두께 및 열처리에 따른 전기적 특성과 workfunction 변화를 관찰하기 위해 I-V, C-V 분석을 진행하였다. 열처리 전후의 이중 금속층의 workfunction은 두 금속층의 확산의 정도에 따라서 열처리 전에는 하위금속층의 workfunction에서 열처리 후에는 상위금속층의 workfunction 값과의 중간값으로 변화하였다. 또한 열처리에 따라 두 금속층 중간에 새로운 금속간 화합물이 형성될 경우 이중 금속층의 workfunction은 새로운 금속간 화합물의 workfuction 값을 나타내었다.

  • PDF

Removal of Impurities from Metallurigical Grade Silicon by Acid Washing (금속급(金屬級) 실리콘에서 산세척(酸洗滌)에 의한 불순물(不純物)의 제거(除去))

  • Lee, Man-Seung;Kim, Dong-Ho
    • Resources Recycling
    • /
    • v.20 no.1
    • /
    • pp.61-68
    • /
    • 2011
  • Impurity removal from metallurgical grade silicon by acid washing at $50^{\circ}C$ was investigated by employing sulfuric, nitric acid and the mixture of hydrochloric and hydrofluoric acid. Acid washing treatment had no effect on the removal of boron and the concentration of this clement after treatment was rather increased. In our experimental range, the removal percentage of phosphorus was 60%. In the acid washing with sulfuric and nitric acid, the removal percentage of major impurities was below 50%, which indicates that refining effect was not great with these acids. Acid washing with the mixture of hydrochloric and hydrofluoric acid led to removal percentage of higher than 90%. Data on the purity of silicon after acid washing at various conditions are reported.

증발증착법에 의해 형성된 금속 입자를 이용한 단결정 실리콘의 습식식각

  • Go, Yeong-Hwan;Ju, Dong-Hyeok;Yu, Jae-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.438-438
    • /
    • 2012
  • 은(Ag) 또는 금(Au) 입자를 촉매로 이용하여 습식식각을 통해 선택적으로 짧은 시간동안 단결정 실리콘 웨이퍼의 표면을 텍스쳐링하여 반사방지막 특성을 효과적으로 얻을 수 있다. 일반적으로 금속입자는 주로 금속 이온이 포함된 용액이나, 전기증착법을 통해서 실리콘 웨이퍼 표면에 형성시켰지만, 금속입자의 크기와 분포를 조절하기 어려웠다. 하지만, 최근 진공장비를 이용하여 열증발증착법(thermal evaporation)과 급속열처리법(rapid thermal annealing)을 통해서 금속입자를 대면적으로 크기와 분포를 균일하게 조절할 수 있다. 이러한 현상은 열적 비젖음(thermal dewetting) 현상에 의해 실리콘 표면위에 증착된 금속 박막으로부터 나노입자로 형성할 수 있다. 본 연구에서는 실리콘 (100)기판위에 다양한 크기의 은 또는 금 나노입자를 형성시켜 식각용액에 짧은 시간동안 담그어 식각하여, 텍스쳐링 효과와 반사방지(antireflection) 특성을 분석하였다. 실험을 위해 각각 은 또는 금 박막을 열증발증착법을 이용하여 ~3-8 nm의 두께로 형성시켰으며, 급속가열장치를 이용하여 $500^{\circ}C$에서 5분 동안 열처리하였다. 그리고 탈이온수(de-ionized water)에 불화수소와 과산화수소가 혼합된 식각용액에 1-5분 동안 습식식각을 하였다. 각각의 텍스쳐링 된 샘플의 식각의 상태와 깊이를 관찰하기 위해 field emission scanning electron microscopy (FE-SEM)을 이용하여 측정하였으며, UV-vis-NIR spectrophotometer를 이용하여 300 nm에서 1,200 nm의 반사특성을 분석하였다. 또한 RCWA (rigorous coupled wave analysis) 시뮬레이션을 이용하여 텍스쳐링 된 기하학적구조에 대하여 반사방지막 특성을 이론적으로 분석하였다.

  • PDF