• Title/Summary/Keyword: 근적외선 분석계

Search Result 21, Processing Time 0.028 seconds

The study of quantitative analytical method for pH and moisture of Hanji record paper using non-destructive FT-NIR spectroscopy (비파괴 분석 방법인 푸리에 변환 근적외선 분광 분석을 이용한 한지 기록물의 산성도 및 함수율 정량 분석 연구)

  • Shin, Yong-Min;Park, Soung-Be;Lee, Chang-Yong;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • It is essential to evaluate the quality of Hanji record paper without damaging the record paper by previous destructive methods. The samples were Hanji record paper produced in the 1900s. Near-infrared (NIR) spectrometer was used as a non destructive method for evaluating the quality of record papers. Fourier transform (FT) spectrometer was used with 12,500 to 4,000 $cm^{-1}$ wavenumber range for quantitative analysis and it has high accuracy and good signal-to-noise ratio. The acidity and moisture content of Hanji record paper were measured by integrating sphere as diffuse reflectance type. The acidity (pH) of chemical factors as a quality evaluated factor of Hanji was correlated to NIR spectrum. The NIR spectrum was pretreated to obtain the coefficients of optimum correlation. Multiplicative scatter correction (MSC) and First derivative of Savitzky-Golay were used as pretreated methods. The coefficients of optimum correlation were calculated by PLSR (partial least square regression). The correlation coefficients ($R^2$) of acidity had 0.92 on NIR spectra without pretreatment. Also the standard error of prediction (SEP) of pH was 0.24. And then the NIR spectra with pretreatment would have better correlation coefficient ($R^2$ = 0.98) and 0.19 as SEP on pH. For moisture contents, the linearity correlation without pretreatment was higher than the case with pretreatment (MSC, $1^{st}$ derivative). As the best result, the $R^2$ was 0.99 and SEP was 0.45. This indicates that it is highly proper to evaluate the quality of Hanji record papers speedily with integrated sphere and FT NIR analyzer as a non-destructive method.

대기압 저온 아르곤 플라즈마 제트의 분광 분석

  • Han, Guk-Hui;Kim, Yun-Jung;Kim, Jung-Gil;Kim, Yeon-Jeong;Jo, Hyeon;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.191-191
    • /
    • 2016
  • 대기압 저온 Ar 플라즈마 제트에서 발생되는 플라즈마에 대해 연구하였다. 플라즈마 제트의 본체는 주사기 바늘, 유리관 그리고 테프론 튜브로 구성되어 있다. 바늘의 앞부분은 유리관에 삽입되어 있으며 바늘의 뒷부분은 테프론 튜브와 연결되어 있다. 주사기 바늘에는 수십 kHz의 사인파를 발생시키는 DC-AC 인버터로 수 kV의 고전압을 인가해준다. 기체는 테프론 튜브를 통해 바늘의 안쪽으로 흐른다. 사용 기체는 Ar이며 유량은 3 lpm이다. 주사기 바늘형 전극의 내경은 1.3 mm, 외경은 1.8 mm, 총 길이는 39.0 mm이며 재질은 스테인레스강이다. 유리관의 내경은 2.0 mm, 외경은 2.4 mm, 총 길이는 80.0 mm이다. 자외선-근적외선 분광계를 이용하여 대기압 저온 Ar 플라즈마 제트에서 발생된 플라즈마의 분광 분석을 하였다. 플라즈마 제트에서 발생되는 플라즈마의 휘도는 대략 $10{\sim}30cd/m^2$이다. 플라즈마의 측정 위치, 플라즈마 제트의 입력 전압과 입력 전류, 기체 종류 등의 변수에 따른 분광 실험을 하였으며 이를 통해 얻은 분광 데이터를 일반적인 볼츠만 기울기법에 대입하여 플라즈마의 들뜸 온도를 측정하였다. 또한 Ar 플라즈마 제트의 분광 데이터를 수정된 볼츠만 기울기법에 대입하여 플라즈마의 전자 온도를 측정하였다. 이는 바이오-의료용 플라즈마 및 플라즈마 공정 등의 다양한 응용 분야에서 유용하게 활용할 수 있을 것이다.

  • PDF

NIR reflecting properties of TiO2/Ag/TiO2 multilayers deposited by DC/RF magnetron sputtering (DC/RF 마그네트론 스퍼터링법을 이용한 TiO2/Ag/TiO2 하이브리드 다층박막의 적외선 반사 특성)

  • Kim, Seong-Han;Kim, Seo-Han;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.158-158
    • /
    • 2016
  • 최근 화석연료의 고갈과 환경 보전 및 에너지 절약에 대한 관심이 높아짐에 따라 화석연료의 소비를 최소화하고 실내조건을 쾌적하게 유지하려는 연구가 진행되고 있다. 국내의 경우 전체 에너지 소비의 30%이상을 차지하고 있는 건물부문에서의 에너지 소비를 줄이기 위한 활발한 연구가 진행되고 있으며 이에 따른 에너지절약 소재개발이 활발하게 진행되고 있다. 1975년 이후 여러 차례에 걸친 단열강화 조치를 통해 건물에서의 에너지 소모를 줄이고 있었으나 건물의 외벽에 대한 사항으로 한정되어있었고, 또한 건물의 창 면적이 증가함에 따라 창을 통한 열손실량과 열획득량이 더욱 증가하게 되었다. 이러한 문제를 해결하기 위해 열반사유리에 대한 많은 연구가 진행되고 있다. 열반사유리는 근적외선(열선)영역의 빛을 반사시켜 실내의 열손실량 및 외부에서의 열획득량을 감소시켜 에너지의 소비를 줄일 수 있는 유리을 말한다. 이러한 열반사유리은 fresnel 방정식을 통해 빛의 파장대에 따른 반사율 및 투과도를 예측할 수 있는데, 다층박막구조인 Oxide-Metal-Oxide(OMO)구조는 Oxide의 높은 굴절률과 Metal의 낮은 굴절률을 통해 가시광영역대의 높은 투과도와 근적외선 영역의 높은 반사율을 얻을 수 있다. 또한 Metal층을 삽입함으로서 flexible한 코팅이 가능하고, 높은 carrier density와 mobility로 표면 플라즈몬 공명을 통해 특정 파장대의 반사율을 높일 수 있으므로 많은 연구가 진행되고 있다. $TiO_2$는 고굴절률 및 낮은 광흡수성의 특성을 가지는 산화물반도체로 기존의 $In_2O_3$계 산화물에 비해 값이 싸고 높은 안정성과 광촉매특성을 보이므로 외부에 노출된 환경에 적합한 재료이다. Ag는 저굴절률과 낮은 광흡수성을 가지는 재료로 금속층에 적합하다. 본 연구에서는 fresnel 방정식을 통해 반사도 및 투과도를 예측하고 마그네트론 스퍼터링법으로 다층박막을 열선인 적외선 영역에서의 반사율 및 반사 효율을 평가하였다. Index-matching 시뮬레이션을 통해 $TiO_2/Ag/TiO_2$ 다층박막의 투과도와 반사도를 이론적으로 검토하였다. 시뮬레이션 프로그램은 Macleod프로그램을 이용하였고 재료 각각의 굴절률은 Ellipsometry를 이용하여 측정하였다. 두께 40 nm 와 8 ~ 16 nm를 가지는 $TiO_2$층과 Ag층을 각각 RF/DC 마그네트론 스퍼터링법을 이용하여 Glass기판 위에 증착하였다. 직경 3 in 의 $TiO_2$, Ag 소결체 타깃을 이용하였고 스퍼터링 파워는 각각 200 W, 50 W로 설정하였고, 스퍼터링 가스는 Ar가스의 유량을 20 sccm으로 설정하였다. 작업압력은 모두 1 Pa로 설정하였고 타깃 표면의 불순물 및 이물질 제거를 위해 Pre-sputtering을 10분 진행하였다. 박막의 두께는 reflectometer와 Alphastep을 이용하여 측정하였고 Hall effect measurement를 이용하여 비저항, carrier density, mobility등 전기적 특성을 측정하였다. 또한 UV-VIS spectrometer와 USPM-RU-W NIR Micro-Spectrophotometer를 통해 광학적 특성을 측정하였고 계산 값과 비교분석하였다. 또한 열반사 특성을 평가하기 위해 직접 set-up한 장비를 이용하였다. 단열 박스에 샘플을 장착해 적외선 램프를 조사하였을 때의 열 반사효율을 평가하였고, IR Camera를 이용하여 단열 박스 내부의 온도 변화를 관찰하였다.

  • PDF

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

A Study on the Thermochromic properties of Ti-doped Vanadium Dioxide (티타늄이 도핑된 이산화 바나듐의 열변색 특성에 관한 연구)

  • Park, Jin Wook;Park, Seong-Soo;Ahn, Byung Hyun;Hong, Seong-Soo;Lee, Gun Dae
    • Clean Technology
    • /
    • v.21 no.4
    • /
    • pp.235-240
    • /
    • 2015
  • In this study, vanadium dioxide was doped with titanium (0~0.5 at %) to improve thermochromic properties. The titanium doped vanadium dioxide (Ti-VO2) particles were prepared via thermolysis process using vanadyl sulfate, ammonium bicarbonate and titianium chloride as precursors. The crystal structure, morphology, chemical bonding and thermochromic properties were investigated by using XRD, FE-SEM, XPS, DSC and UV-Vis-NIR spectroscopy. It was found that titanium was successfully doped into the crystal lattice of VO2 and the obtained Ti-VO2 particles have monoclinic structure. With increasing Ti concentration, the particle size and phase transition temperature of Ti-VO2 particles decreased and NIR switching efficiency increased.

Near-IR Spectroscopic Studies of the Hydrogen Bonding between Thioacetamide and N,N-Dimethylacetamide in $CCl_4$ ($CCl_4$중에서 Thioacetamide와 N,N-Dimethylacetamide사이의 수소 결합에 관한 분광학적인 연구)

  • Kang Bong Lee;Byung-Chul Kim;Chang-ju Yun;O. D. Bonner;Young-Sang Choi
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.510-515
    • /
    • 1986
  • Spectra for the $v_3$+ Amide II combination band of thioacetamide(TA) were obtained in carbon tetrachloride solutions and in very dilute solutions of TA-N,N-dimethlylacetamide (DMA) in carbon tetrachloride in the range of 5~55$^{\circ}$C. The combination band in the three component system can be resolved into components due to monomeric TA, 1 : 1 TA-DMA complex and 1 : 2 TA-DMA complex. In the dilute solutions the experimental spectrum was resolved by using the computer into its two Lorentzian-Gaussian product components which have been identified with the monomeric TA and the 1 : 1 complex. The equilibrium constants and thermodynamic parameters of 1 : 1 complex were determined by analysis of concentration and temperature dependent spectra. The ${\Delta}H^{\circ}$ and ${\Delta}S^{\circ}$ for the 1 : 1 complex were -14.4 KJ mol$^{-1}$ and -15.6 J mol$^{-1}deg^{-1}$, respectively.

  • PDF

Cure and Mechanical Behaviors of Cycloaliphatic/DGEBA Epoxy Blend System using Electron-Beam Technique (전자선 조사에 의한 고리지방족/DGEBA 에폭시 블렌드 시스템의 경화 및 기계적 특성)

  • 이재락;허건영;박수진
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.210-216
    • /
    • 2003
  • 4-Vinyl-1-cyclohexene diepoxide (VCE)/diglycidyl ether of bisphenol-A (DGEBA) epoxy blends with benzylquinoxalinium hexafluoroanti-monate were cured using an electron-beam technique. The effect of DGEBA content to VCE on cure behavior, thermal stabilities, and mechanical properties was investigated. The composition of VCE/DGEBA blend system vaned within 100:0, 80:20, 60:40, 40:60, 20:80, and 0:100 wt%. The cure behavior and thermal stability of the cured specimens was monited by near-infrared spectroscopy and thermogravimetric analysis, respectively. Also, the critical stress intensity factor ($_{4}$) test of the cured specimens was performed to study the mechanical interfacial properties. As a result, the decreases of short side-chain structure and chain scission were observed in NIR measurements as the DGEBA content increases, resulting in varying the hydroxyl and carbonyl groups. And, the initial decomposition temperature (IDT), temperature of maximum weight loss (T$\_$max/), and decomposition activation energy (E$\_$d/) as thermal stability factors were increased with increasing the DGEBA content. These results could be explained by mean of decreasing viscosity, stable aromatic ring structure, and grafted interpenetrating polymer network with increasing of DGEBA content. Also, the maximum $_{4}$ value showed at mixing ratio of 40:60 wt% in this blend system. in this blend system.

Evaluation of Rededge-M Camera for Water Color Observation after Image Preprocessing (영상 전처리 수행을 통한 Rededge-M 카메라의 수색 관측에의 활용성 검토)

  • Kim, Wonkook;Roh, Sang-Hyun;Moon, Yongseon;Jung, Sunghun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.167-175
    • /
    • 2019
  • Water color analysis allows non-destructive estimation of abundance of optically active water constituents in the water body. Recently, there have been increasing needs for light-weighted multispectral cameras that can be integrated with low altitude unmanned platforms such as drones, autonomous vehicles, and heli-kites, for the water color analysis by spectroradiometers. This study performs the preprocessing of the Micasense Rededge-M camera which recently receives a growing attention from the earth observation community for its handiness and applicability for local environment monitoring, and investigates the applicability of Rededge-M data for water color analysis. The Vignette correction and the band alignment were conducted for the radiometric image data from Rededge-M, and the sky, water, and solar radiation essential for the water color analysis, and the resultant remote sensing reflectance were validated with an independent hyperspectral instrument, TriOS RAMSES. The experiment shows that Rededge-M generally satisfies the basic performance criteria for water color analysis, although noticeable differences are observed in the blue (475 nm) and the near-infrared (840 nm) band compared with RAMSES.

Heavy Metal Contamination Characteristics and Spectral Characteristics of White Precipitation occurring at Miin Falls Drainage (미인폭포 수계에서 발생하는 백색침전물의 중금속 오염 및 분광학적 특성)

  • Lim, Jeong Hwa;Yu, Jaehyung;Shin, Ji Hye;Jeong, Yong Sik;Koh, Sang-Mo;Park, Gyesoon
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.31-43
    • /
    • 2017
  • This study investigated mineralogy, spectral characteristics and heavy metal contamination including Cd, Ni, Al, Fe, Mn and S for white precipitation in Miin falls based on XRF, XRD, and spectrometer. As a result, Al concentration was abnormally high at all samples, and most of the samples showed high contamination level in Cd and Ni. XRD results detected quartz, kaolinite, rhomboclase, aluminocoquimbite, and gibbsite which infers that heavy metal elements are distributed by adsorption with clay minerals. Spectral characteristics of white precipitation can be described by increasing pattern of reflectance in visible spectrum and decreasing pattern of reflectance in longer wave length including near infrared and shortwave infrared spectrum. The absorption features reveals that spectral characteristics of white precipitation is mainly controlled by kaolinite, rhomboclase, aluminocoquimbite, and gibbsite. The relationship between heavy metal concentration and absorption depth showed high positive correlation for Al concentration and absorption feature at 2202 nm of Al-OH absorption. This spectral characteristics indicates that absorption depth could be effectively used for estimation of heavy metal concentration.

Comparative Evaluation of UAV NIR Imagery versusin-situ Point Photo in Surveying Urban Tributary Vegetation (도심소하천 식생조사에서 현장사진과 UAV 근적외선 영상의 비교평가)

  • Lee, Jung-Joo;Hwang, Young-Seok;Park, Seong-Il;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.475-488
    • /
    • 2018
  • Surveying urban tributary vegetation is based mainly on field sampling at present. The tributary vegetation survey integrating UAV NIR(Unmanned Aerial Vehicle Near Infrared Radiance) imagery and in-situ point photo has received only limited attentions from the field ecologist. The reason for this could be the largely undemonstrated applicability of UAV NIR imagery by the field ecologist as a monitoring tool for urban tributary vegetation. The principal advantage of UAV NIR imagery as a remote sensor is to provide, in a cost-effective manner, information required for a very narrow swath target such as urban tributary (10m width or so), utilizing very low altitude flight, real-time geo-referencing and stereo imaging. An exhaustive and realistic comparison of the two techniques was conducted, based on operational customer requirement of urban tributary vegetation survey: synoptic information, ground detail and quantitative data collection. UAV NIR imagery made it possible to identify area-wide patterns of the major plant communities subject to many different influences (e.g. artificial land use pattern), which cannot be acquired by traditional field sampling. Although field survey has already gained worldwide recognition by plant ecologists as a typical method of urban tributary vegetation monitoring, this approach did not provide a level of information that is either scientifically reliable or economically feasible in terms of urban tributary vegetation (e.g. remedial field works). It is anticipated that this research output could be used as a valuable reference for area-wide information obtained by UAV NIR imagery in urban tributary vegetation survey.