• Title/Summary/Keyword: 근원심 경사도

Search Result 17, Processing Time 0.019 seconds

Reproducibility and accuracy of tooth size measurements obtained by the use of computer (컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구)

  • Kim, Eun-Jeong;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.563-573
    • /
    • 1999
  • The purpose of this study was to evaluate the availability of computer system for the measurement of tooth size in the model analysis through the comparison of two measurements: One was to use a computer; and the other was to use vernier calipers. Twenty sets of casts were used, which showed a moderate degree of crowding and full eruption of all teeth. The mesio-distal width of 12 teeth from the left central incisor to the left first molar at each set of the casts were measured twice with vernier calipers and a computer respectively. This measurement was repeated two weeks later. First, for the reproducibility analysis, the two computer measurements were compared then the vernier calipers measurements were compared. Second, all the teeth were sepapated into the region of mesiodistal contact points and its width was measured by a micrometer to obtain standard measurements. For the accuracy analysis, these standard measurements were compared with the measurements from the dental casts using two methods. The difference between them was defined as the measurement error. To investigate the cause of measurement error, an examination was made for the presence and degree of contact point deviation on each tooth from the upper and lower occlusograms, and the mesio-distal angulation of each tooth was measured with TARG. Following results were obtained through statistical analysis. 1. In the analysis for reproducibility; the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in one out of twelve teeth. 2. In the analysis for accuracy; compared with the standard measurements, the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in two out of twelve teeth. 3. Compared with the standard measurements, the measurements with vernier calipers were apt to be larger at the upper first molar, and smaller at the lower first molar The computer measurements, however, were apt to be larger at both upper and lower first molars. 4. The measurements with vernier calipers showed the largest error at the lower first molar and the degree of error was variable according to the tooth while the difference of error was small in the computer measurements. 5. In the analysis for the correlation of the degree of measurement errors with the contact point deviation index and the mesio-distal crown angulation of each tooth, the measurements with vernier calipers did not show significant correlation while the measurements with computer showed slight Positive correlations. The results of this study indicate that a computer system may be useful for the measurement of tooth size in the model analysis.

  • PDF

Three-dimensional finite element analysis on the effect of maxillary incisor torque (상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구)

  • Yoon, Hyun-Joo;Lim, Yong-Kyu;Lee, Dong-Yul;Jo, Yung-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.137-147
    • /
    • 2005
  • The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, $.022{\times}.028$ Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees ThHe findings of this study showed that the reaction force acting or the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied. labial crown and distal tipping and Intrusion of the incisors took place. and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used NiTi or TMA wire is desirable for torque control.

A CEPHALOMETRIC STUDY ON MESIODISTAL AXIAL INCLINATION OF POSTERIOR TEETH IN OPEN BITE AND DEEP BITE (개방교합과 과개교합에서 구치의 근원심 치축경사도에 관한 두부방사선계측학적 연구)

  • Jeon, Sang-Beom;Kim, Jin-Beom;Shon, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.391-403
    • /
    • 1993
  • For the purpose of investigating mesiodistal axial inclination of posterior teeth in normal occlusion group, open bite and deep bite group and investigating the correlationship between the axial inclination of posterior teeth and overbite of anterior teeth, a cephalometric study was performed on the subjects consisted of normal occlusion group(40), open bite group(71 : Angle's Class I, Class II, division 1 25, Class III 25) and deep bite group(64 : Angle's Class I 23, Class II, division 1 21, Class III 20). Mesiodistal axial inclination of posterior teeth to occlusal, mandibular and palatal plane were measured. The findings of this study were as follows : 1. Upper and lower posterior teeth were more mesially inclined to occlusal plane in open bite group than in deep bite group. 2. Lower posterior teeth were more mesially inclined in deep bite group than in open bite group in Angle's Class II, division 1 malocclusion but there were no significant differences in Angle's Class I and Class III malocclusion. 3. There was no significant correlationship between the axial inclination of posterior teeth to each plane and overbite of anterior teeth in open bite group. 4. There was a significant correlationship between the axial inclination of upeer and lower second premolar to occlusal plane and overbite of anterior teeth in Angle's Class I, Class II, division 1 and Class III malocclusion.

  • PDF

Effect of maxillary premolar extraction on transverse arch dimension in Class III surgical-orthodontic treatment (III급 부정교합의 수술-교정 치료시 상악 소구치 발치가 치열궁 폭경 변화에 미치는 영향)

  • Lee, Shin-Jae;Hong, Sung-Joon;Kim, Young-Ho;Baek, Seung-Hak;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.23-34
    • /
    • 2005
  • Collective changes caused by orthodontic tooth movement evaluated in a specific treatment modality could give suggestive information on the specific treatment strategy. The aim of this study was to investigate retrospectively the characteristics of the orthodontic tooth movement during surgical-orthodontic treatment in order to provide an effective presurgical orthodontic treatment planning for the maxillary premolar extraction modality In the skeletal Class III malocclusion patient. Pre- and post-treatment dental casts of skeletal Class III malocclusion patients with nonextraction (N=:24) and the maxillary premolar extraction (N=31) were collected. The angulation and inclination measuring gauge(Invisitech Co. Seoul, Korea) was used to evaluate the orthodontic tooth movement. The changes in the maxillary and mandibular dental arch widths were also measured from the canines to the second molars. As a result, more palatal inclination change in the maxillary dentition was found with the premolar extraction modality than with the nonextraction modality. Linear regression analysis showed that the inter-arch width coordination was mainly due to the inclination changes of maxillary posterior teeth We conclude that the indications and proper treatment planning for surgical-orthodontic treatment in skeletal Class III malocclusion with maxillary premolar extraction could depend partly on the magnitude of the transverse inter-arch coordination especially in the maxillary dentition.

Mesiodistal tooth angulation to segmental occlusal plane in panoramic radiography (파노라마방사선사진에서 구획별 교합면 기준선에 대한 치아근원심경사)

  • Kim Jae-Duk;Kim Jin-Soo;You Choong-Hyun
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.25-31
    • /
    • 2005
  • Purpose : To evaluate the stability of the segmental occlusal plane and anatomical line as the reference line for measuring the mesiodistal tooth angulation in panoramic radiography and to determine the mean angle and the range of the mesiodistal tooth angulation in Korean population with normal occlusions. Materials and Methods : Twenty nine subjects (15 men, 14 women) with normal occlusion were selected. A total of 29 panoramic radiograms were taken at normal head position and then 10 images of 5 subjects selected were repeatedly taken with repositioning 2 times at each of the head down (V-shaped occlusion) and up (horizontal occlusion) for evaluation of stability of adopted reference lines by using PM2002CC (Planmeca, Finland). The images were traced with adoption of two test reference lines and the long axes of the teeth. The mesial angles formed by each reference line and the long axes of the teeth were measured and analyzed. Results : With anatomical reference line, the mesiodistal tooth angulations of the molars showed the significant difference by over 5 degree between the normal and each changed head position. With segmented occlusal reference line, deviations of mesiodistal tooth angulations by the two changed head positions were less than 1 degree. The means, standard deviations, and maximum and minimum values of mesiodistal tooth angulations to segmental occlusal reference line on panoramic radiography were determined. Conclusion : It would appear that mesiodistal tooth angulations to segmental occlusal plane as reference line in panograms are predictable as standards of normal occlusion and useful for evaluation of tooth arrangement between adjacent teeth.

  • PDF

Stratigraphy and Provenance of Non-marine Sediments in the Tertiary Cheju Basin (제주분지 제삼기 육성층의 층서 및 퇴적물 기원)

  • Kwon Young-In;Park Kwan-Soon;Yu Kang-Min;Son Jin-Dam
    • The Korean Journal of Petroleum Geology
    • /
    • v.3 no.1 s.4
    • /
    • pp.1-15
    • /
    • 1995
  • Seismic reflection profiles and exploratory drilling well samples from the southern marginal-continental shelf basin of Korea delineate that the Tertiary sedimentary sequences can be grouped into five sequences (Sequence A, Sequence B, Sequence C, Sequence D and Sequence E, in descending order). Paleontologic data, K-Ar age datings, correlation with tuff layers and sequence stratigraphic analysis reveal that the sequences A, B, C, D and E can be considered as the deposits of Holocene $\~$ Pleistocene, Pliocene, Late Miocene, Early $\~$ Middle Miocene and Oligocene, respectively. The sequence stratigraphic and structural analyses suggest that the southern part of the Cheju Basin had experienced severe folding and faulting. NE-SW trending strike-slip movement is responsible for the deformation. The sinistral movement of strike-slip fault ceased before the deposition of Sequence B. Age dating and rare-earth elements analysis of volvanic rocks reveal+ that the Sequence D was deposited during the Early $\~$ Middle Miocene and the Sequence I was deposited earlier than the deposition of the Green Tuff Formation. Sedimentary petrological studies indicate that sediments of the Sequence I came from the continental block provenance. After the deposition of the Sequence E, uplift of the source area resulted in increase of sediment supply, subsidence and volcanic activities. The Sequence D show these factors and the sediments of the Sequence D are considered to be transported from the recycled orogenic belt.

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF