• 제목/요약/키워드: 근관와동

검색결과 31건 처리시간 0.036초

근관와동 가봉재 종류에 따른 변연누출의 비교 분석 (COMPARATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS TEMPORARY SEALING MATERIALS)

  • 윤창;홍석진
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.151-157
    • /
    • 1991
  • The roles of temporary sealing materials used in endodontics are impotant Especially, its marginal sealing properties affect endodontic success and failure in endodontic treatment The purpose of this in vitro study was to compare and evaluate the marginal sealing properties of various temporary restorative materials used in endodontic access cavity by using electrochemical method. Standard endodontic access cavities were prepared in extracted human molar teeth and filled with Caviton, IRM, zinc oxide - eugenol cement. Each specimen was immersed in 1 % solution of KCl, and applied a potential of 9 V external power supply. Marginal microleakage and water sorption were measured for marginal sealing effect evaluation in comparison with each group. A comparative study of the obtained results have led to the following conclusions. 1. The Caviton group showed lower marginal microleakage value than the zinc oxide - eugenol cement and IRM group the 6 th day after. The IRM group showed lwoer marginal microleakage value than the zinc oxide - eugenol cement group from the 6 th day to the 12 th day. But there was no significant difference between zinc oxide - eugenol cement and IRM group after the 13 th day. 2. As time went by, marginal microleakage value was increased in Caviton, IRM and zine oxide - eugenol cement.

  • PDF

근관와동 가봉재의 변연누출에 관한 실험적 연구 (A STUDY ON THE MARGINAL LEAKAGE OF ENDODONTIC CAVITY FILLING MATERIALS)

  • 노철진;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제12권2호
    • /
    • pp.17-23
    • /
    • 1987
  • The purpose of this study was to evaluate the sealing properties of endodontic cavity filling materials according to the time intervals after filling. Access cavities were prepared in extracted human premolar or molar teeth and filled with caviton, zinc oxide eugenol cement, zinc oxide eugenol cement with a base of gutta percha stopping and gutta percha stopping. After filling at the intervals of immediate, 2 days and 2 weeks the teeth were immersed for 2 weeks in 1% methylene blue solutions. Longitudinal sections were obtained from approximately center of teeth and the depth of dye penetration into the access cavities were observed by 10${\times}$macrolens. The following results were obtained. I. All the materials experimented showed varying depth of dye penetration. 2. Of the material tested, caviton showed the best marginal sealing qualities regardless of the time intervals after filling and the sealing properties of the gutta percha stopping was the worst. 3. Both in zinc oxide eugenol cement and zinc oxide eugenol cement with a base of gutta percha stopping, the fillings allowed to mature for 2 days in normal saline solution showed the best sealing properties and those with no maturing time revealed the worst sealing qualities. 4. The sealing qualities of zinc oxide eugenol cement with a base of gutta percha stopping revealed slightly lower depth of dye penetration than that of zinc oxide eugenol cements.

  • PDF

수복물의 종류가 근관치료된 상악 제2소구치의 응력분포에 미치는 영향: 3차원 유한요소법적 연구 (EFFECT OF RESTORATION TYPE ON THE STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY PREMOLARS; THREE-DIMENSIONAL FINITE ELEMENT STUDY)

  • 정현숙;김현철;허복;김광훈;손권;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제34권1호
    • /
    • pp.8-19
    • /
    • 2009
  • 본 연구의 목적은 다양한 교합하중 조건하에서 아말감, 복합레진, 세라믹 인레이, 그리고 금 인레이로 수복한 근관치료된 상악 제2소구치의 음력분포를 3차원 유한요소법으로 분석하는 것이다. 발치된 상악 제2소구치를 이용하여 근관치료된 3차원 유한요소모형을 제작하였다. 제작된 소구치 모형의 근관와동을 위 4가지 재료로 각각 수복한 후, 협측교두 (Load-1) 또는 설측교두 (Load-2)에 500 N의 하중을, 설측교두와 근심변연에 총 170 N의 하중 (Load-3)을 가하였다. 세 가지의 하중조건 하에서 각 수복물에 따른 협측과 설측의 치경부 그리고 교합면의 정중구에서 나타나는 인장응력의 분포양상을 ANSYS 프로그램으로 분석하여 다음과 같은 결과를 얻었다. 1. 모든 수복물의 경우에서 Load-1에서는 설측의 치경부, Load-2에서는 협측의 치경부에서 높은 응력이 관찰되었고 수복물 종류에 따른 차이는 관찰되지 않았다. 2. 모든 수복물의 경우에서 교합면의 하중점 근처 와정중구를 따라 높은 응력이 관찰되었고 수복물 종류에 따라 약간의 차이가 관찰되었다. 3. 모든 수복물의 경우에서 Load-3에서는 하중점 근처에서 높은 응력이 관찰되었고 수복물 종류에 따른 차이는 관찰되지 않았다.

초음파 다이아몬드 기구의 상아질 삭제 효과, 치근단 역충전 와동 형성효율 및 치질에의 영향 (EFFICIENCY OF DENTIN CUTTING AND ROOT -END RETROCAVITY PREPARATION USING ULTRASONIC DIAMOND INSTRUMENTS AND THEIR INFLUENCE ON TOOTH STRUCTURE)

  • 임춘희;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.54-67
    • /
    • 1998
  • 치근단 역충전 와동 형성을 위한 초음파 다이아몬드 기구의 임상적 적용의 타당성 및 특성을 평가하기 위해, 다이아몬드 기구의 상아질 삭제능력, 역충전 외동 형성효율 및 치질에 미치는 영향을 관찰하여 스테인레스 스틸 기구와 비교, 평가하였다. 치근단 역충전 와동 형성시 다이아몬드 기구와 스테인레스 스틸 기구를 발거된 소의 치아에서 노출시킨 상아질 표변에 일정한 출력과 시간 조건 하에서 작동시켜 상아질 표면으로부터의 삭제된 깊이를 측정하였다. 역충전 와동 형성효율을 평가하기 위하여 발거된 상악 제 1 대구치 치근에서 근관을 형성하고 gutta-percha로 충전한 다음 근단 3mm부위를 치아 장축에 직각되게 절제하고 초음파 기구의 와동형성 소요 시간 및 소요 stroke 수를 측정하였다. 초음파 기구를 이용한 와동 형성이 치질에 미치는 영향을 평가하기 위하여 초음파 와동 형성 전후의 치근단부 치질의 균열 발생빈도를 측정, 평가하여 다음과 같은 결과를 얻었다. $\cdot$ 저출력 또는 중출력에서 그리고 노출된 상아질에 수직 또는 수평으로 기구를 적용한 경우 모두에서, 다이아몬드 기구가 스테인레스 스틸 기구에 비해 높은 상아질 삭제효과를 나타내었다(p<0.01). $\cdot$ 초음파기구를 상아질 표면에 수직으로 적용한 경우에 출력이 높을수록 상아질 삭제효과가 우수하였으며, 수평으로 적용한 경우에는 출력에 따른 유의한 증가가 나타나지 않았다(p<0.01). $\cdot$ 중출력에서는 다이아몬드 기구가 스테인레스 스틸 기구에 비해 와동형시 소요되는 stroke 수와 시간으로 본 와동형성효율이 유의하게 우수하게 나타났다(p<0.05). $\cdot$ 저출력에서는 다이아몬드 기구가 스테인레스 스틸 기구에 비해 외동형성 후 치근단 균열 발생빈도가 유의하게 적게 나타났다(p<0.01).

  • PDF

근관와동형태에 따른 근관치료된 하악절치의 파절강도 (THE INFLUENCE OF DIFFERENT ACCESS CAVITY DESIGNS ON THE FRACTURE STRENGTH IN ENDODONTICALLY TREATED MANDIBULAR ANTERIOR TEETH)

  • 이영균;신혜진;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.515-519
    • /
    • 2004
  • Straight access cavity design allows the operator to locate all canals, helps in proper cleaning and shaping, ultimately facilitates the obturation of the canal system. However, change in the fracture strength according to the access cavity designs was not clearly demonstrated yet. The purpose of this study was to determine the influence of different access cavity designs on the fracture strength in endodontically treated mandibular anterior teeth. Recently extracted mandibular anterior teeth that have no caries, cervical abrasion, and fracture were divided into three groups (Group 1 : conventional lingual access cavity, Group 2 : straight access cavity, Group 3 : extended straight access cavity) according to the cavity designs. After conventional endodontic treatment, cavities were filled with resin core material. Compressive loads parallel to the long axis of the teeth were applied at a crosshead speed of 2mm/min until the fracture occurred. The fracture strength analyzed with ANOV A and the Scheffe test at the 95% confidence level. The results of this study were as follows: 1. The mean fracture strength decrease in following sequence Group 1 (4558.90{\;}\pm{\;}77.40{\;}N$), Group 2 ($494.07{\;}\pm{\;}123.98{\;}N) and Group 3 ($267.33{\;}\pm{\;}27.02{\;}N). 2. There was significant difference between Group 3 and other groups (P = 0.00). Considering advantage of direct access to apical third and results of this study, straight access cavity is recommended for access cavity form of the mandibular anterior teeth.

미세 치근단 수술의 성공과 실패 (Success and failure of endodontic microsurgery)

  • 송민주;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제36권6호
    • /
    • pp.465-476
    • /
    • 2011
  • 최근의 근관치료학 분야에서 외과적 재치료는 수술현미경, 초음파기구, 미세수술기구 등의 도입으로 많은 변화가 있어 왔다. 본 논문에서는 기존의 전통적인 치근단 수술법과 비교하여 미세 치근단 수술의 주요 술식을 알아보고 이미 출간된 논문에 근거하여 미세 치근단 수술의 성공과 실패 그리고 성공과 실패에 영향을 미치는 요소들을 고찰하고자 하였다. 수술현미경은 수술부위를 밝게 확대해서 봄으로써 치근단 부위의 미세한 형태를 조명할 수 있게 되었으며 이는 술식의 성공을 위해서 필수적인 요소가 되었다. 초음파 기구 또한 치근단 역충전을 위한 정확한 와동형성을 가능하게 해 주었다. 따라서 미세 치근단 수술은 기존방식의 문제점이었던 많은 골삭제, 경사진 치근절제, 부정확한 역충전 와동 형성, 치근단 미세구조 관찰의 어려움 등을 극복함으로써 술식이 더욱 정확해지고, 성공가능성이 더 높아졌다고 볼 수 있다. 미세 치근단 수술에 영향을 미치는 요소에는 다양한 요인들이 존재할 수 있으나 전통방식의 치근단 수술보다 술식이 표준화 됨으로써 술식에 의한 영향을 줄일 수 있다. 환자와 치아에 관계되는 요소 중에서는 치주질환의 이환 여부와 치아위치(tooth position)가 예후에 영향을 미치는 것으로 알려져 있으나 이에 대한 연구는 아직까지 그 수가 부족한 상태로 앞으로 검증수준 (evidence level)이 높은 Randomized clinical trial 혹은 전향적 코호트 연구가 많이 이루어져야 할 것이다.

과산화수소의 농도와 적용시간이 상아질의 깊이에 따라 레진 수복물의 미세인장결합강도에 미치는 영향 (THE EFFECT OF CONCENTRATION AND APPLICATION TIME OF HYDROGEN PEROXIDE ON THE MICROTENSILE BOND STRENGTH OF RESIN RESTORATIONS TO THE DENTIN AT DIFFERENT DEPTHS)

  • 손정룡;이계영;강유미;오영택;이광원;김태균
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.406-414
    • /
    • 2009
  • 본 연구의 목적은 심부 상아질과 치수실 상아질에 $H_2O_2$를 각기 다른 적용시간과 농도로 적용하였을 때, 레진수복물과의 미세인장결합강도에 미치는 영향을 평가하는 것이다. 준비된 각각의 치아에 전형적인 근관와동을 형성하고 다음과 같이 무작위로 1개의 대조군과, 4개의 실험군으로 나누었다: 1군, 전처리를 시행하지 않았다; 2군, 20% $H_2O_2$를 20분, 10분, 5분간 적용하였다; 3군, 10% $H_2O_2$를 20분, 10분, 5분간 적용하였다; 4군 5% $H_2O_2$를 20분, 10분, 5분간 적용하였다; 5군, 2.5% $H_2O_2$를 20분, 10분, 5분간 적용하였다. 위와 같이 처리한 후 와동 내를 Superbond C&B(Sunmedical, Co., Shiga, Japan)로 충전하였다. 각 치아는 $37^{\circ}C$ 증류수에 24시간 저장한 뒤 심부 상아질과 치수실 상아질로 잘라 미세인장결합강도 시험을 시행하였다. 각 군에서 측정된 미세인장결합강도를 3-way ANOVA와 Tukey post hoc test로 통계 처리하였다(p < 0.05). 실험 결과 모든 군에서 심부 상아질(D1)의 미세인장 결합강도가 치수실 상아질(D2)보다 높게 나타났다. 평균 결합강도는 $H_2O_2$의 농도와 적용 시간이 증가할수록 감소하였다. 통계분석에서 상아질의 깊이, $H_2O_2$ 농도와 적용 시간이라는 세 가지 변수간의 교호작용 효과는 없으나(p > 0.05). 상아질의 깊이와 $H_2O_2$ 농도 사이, $H_2O_2$ 농도와 적용 시간 사이에서는 교호작용 효과가 있었다(p < 0.05). SEM 관찰에서는 $H_2O_2$의 농도가 증가할수록 상아세관이 좀 더 개방된 양상을 보였다.

MTA와 4-META/MMA & TBB레진 혼합 재료의 치근단 미세누출에 관한 연구 (APICAL MICROLEAKAGE OF MTA WITH 4-META/MMA & TBB RESIN AS A ROOT-END FILLING MATERIAL)

  • 김진철;김미리;고현정;양원경
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.371-376
    • /
    • 2009
  • 이 연구에서는 Mineral Trioxide Aggregate (MTA)와 4-methacryloxyethyl trimellitate anhydride (4-META) / methyl methacrylate (MMA) & tri-n-butylborane (TBB) 레진을 혼합하여 치근단 역충전 재료로 사용하였을 때의 미세누출을 MTA, 포틀랜드 시멘트와 비교하였다. 발치된 사람 치아의 근관형성 및 충전 후 치근단 절제와 역충전 와동을 형성하였다. MTA, Portland cement, MTA와 4-META/MMA & TBB레진을 혼합한 각각의 재료로 치근단을 역충전한 후 methylene blue dye에 72시간 동안 침적하여 염료가 침투한 길이를 10배 현미경 하에서 측정하였다. MTA와 4-META/MMA & TBB 레진 혼합 충전 군에서는 포틀랜드 시멘트나 MTA 충전군보다 통계적으로 유의하게 적은 미세 누출을 보였으며, 포틀랜드 시멘트와 MTA 충전군의 미세 누출 정도는 통계적으로 차이가 없었다. 이 실험의 결과로 보아 MTA와 4-META/MMA & TBB레진 혼합 재료는 치근단 역충전시 포틀랜드 시멘트나 MTA에 비해 낮은 초기 미세누출을 보여, 치근단 봉쇄 효과가 우수한 것으로 사료된다.

NaOCl의 적용 후 치수강 상아질에 대한 결합강도의 변화와 Sodium Ascorbate에 의한 환원 효과 (CHANGES IN μ-TBS TO PULP CHAMBER DENTIN AFTER THE APPLICATION OF NAOCL & REVERSAL EFFECT BY USING SODIUM ASCORBATE)

  • 권수미;김태균;유미경;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제34권6호
    • /
    • pp.515-525
    • /
    • 2009
  • 본 연구에서는 치수강이 개방된 근관와동에 5.25% NaOCl용액을 각각 다른 시간 동안 적용시킨 뒤 접착레진에 의한 미세인장결합강도의 변화를 측정하였으며, 10% sodium ascorbate를 NaOCl 용액에 일정시간 노출시킨 상아질에 다시 10분 동안 적용하여 결합강도에 미치는 효과를 연구하고자 하였다. 연구결과 본 실험에서 상부 치수강 상아질과 하부 치수강 상아질에 대한 결합강도는 모든 실험군내에서 유의한 차이 (p > 0.05)를 보이지 않았다. 5.25% NaOCl 용액을 적용하지 않고 치수강 상아질에 접착시킨 대조군에 비해 20분간 적용시킨 실험군에서는 결합강도의 감소가 초래되었으나 통계적인 유의성 (p > 0.05)은 없었다. 그러나 5.25% NaOCl 용액을 40분과 80분 동안 치수강 상아질에 적용시킨 실험군에서는 대조군에 비해 유의하게 낮은(p < 0.05) 결합강도의 변화를 나타내었다. 5.25% NaOCl 용액을 40분동안 그리고 10% sodium ascorbate를 10분간 처리한 실험군에서는 유의한 결합강도의 회복을 나타내었다. 그러나 5.25% NaOCl 용액을 80분 동안 그리고 10% sodium ascorbate를 10분간 적용한 실험군에서는 대조군에 비해 통계적으로 유의한 차이(p < 0.05)를 보임으로써 여전히 결합강도가 회복되지 못하고 있음을 나타내었다. 5.25% NaOCl 용액을 5분간 적용한 뒤 10% sodium ascorbate를 10분간 적용한 실험군에서는 오히려 대조군에 비해 높은 결합강도(p < 0.05)를 보여줌으로써 높은 회복효과를 나타내었다.

치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰 (Physical properties of novel composite using Portland cement for retro-filling material)

  • 이상진;조옥인;염지완;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.445-452
    • /
    • 2010
  • 연구목적: 이 연구의 목적은 새로운 근단 역충전 재료를 개발하기 위해 MTA, MTA와 AH-plus 혼합물 (AMTA), 그리고 실험적 개발재료인 Portland cement-Epoxy resin composite (EPPC)의 미세 누출 및 물리적인 성질을 비교하는 것이다. 연구 재료 및 방법: 발거 치아 49개를 근관 성형하고 gutta-percha와 sealer로 충전하였다. 각 치아의 치근을 근단부 3 mm에서 절단하고 3 mm 깊이의 역충전 와동을 형성하였다. 15개씩 무작위로 분류한 치근을 세 군으로 나누어 각각 MTA, AMTA, EPPC로 충전하였고 네 개의 치근은 대조군으로 사용하였다. 각 군의 재료로 역충전이 완료된 모든 실험군을 젖은거즈로 덮고 24시간 동안 경화시켰다. 경화 후 72시간 동안 1% methylene blue 염색액에 담근 후, 치근단을 수직 절단하여 사진을 촬영하고 미세 누출을 평가하였다. Vicat apparatus를 사용하여 실험군 별로 경화시간을 측정하였으며, aluminum step wedge를 사용한 디지털 방사선 사진을 촬영하여 각 군의 방사선 불투과도를 평가하였다. 미세누출과 경화시간에 대해 각 군간의 차이를 일원배치분산분석 및 Scheffe 사후 검증으로 유의수준 95%에서 평가하였다. 결과: AMTA와 EPPC는 MTA군에 비해 적은 미세누출량을 보였다 (p < 0.05). AMTA는 가장 높은 방사선 불투과도를 보였으며 개발 재료인 EPPC군은 5 mm aluminum 두께의 방사선 불투과도를 보였다. MTA가 가장 긴 경화시간을 나타낸반면 EPPC군은 다른 군에 비해 초기경화와 최종경화 모두 가장 짧은 경화시간을 나타냈다 (p < 0.05). 결론: 이 연구 조건하에서, 신개발 재료인 EPPC는 치근단 역충전 재료로서 기존의 MTA보다 양호한 밀폐능력과 방사선 불투과성 및 짧은 경화시간 등의 역충전 재료로서 적절한 물리적 성질을 가진 것으로 보인다.