• Title/Summary/Keyword: 근거리선로고장

Search Result 3, Processing Time 0.02 seconds

Parameter Tuning of Artificial Lines for SLF tests on Circuit Breakers Considering Stray Capacitances of Testing and Measuring Equipment (근거리선로고장시험의 실제시험상태를 고려한 인공선로 파라미터 조정)

  • Lee, Yong-Han;Rhyou, Hyeong-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.544-547
    • /
    • 2002
  • In a high power laboratory, artificial lines are used for SLF tests of circuit breakers. The line side PTRV is affected by the stray capacitances of testing and measuring equipment as well as the circuit parameters of artificial lines. The changing pattern of PTRV was examined, and the circuit parameters of artificial line for some examples were compensated using the changing pattern to satisfy test conditions specified.

  • PDF

Analysis of SLF Interruption Performance in self-blast Gas Circuit Breaker (복합소호형 가스 차단기의 SLF 차단 성능 해석)

  • Park, Jin-gun;Ahn, Hee-sup;Choi, Jongung;Kim, Younggeun;Cho, Heayong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.9
    • /
    • pp.24-32
    • /
    • 2020
  • A self-blast type gas circuit breaker has been studied in this study to improve efficiency of interrupting performance of short line fault(SLF). Hot gas flows of gas circuit breaker have been simulated to evaluate interruption performance using CFD. Design parameters such as various types of expansion chamber and nozzles are suggested by using simulation results. Simulated results and experimental ones are compared with previous (ones that of in under development and with capacitor) GCB. Modified new shape of an expansion chamber and nozzle has been suggested to improve the efficiency of gas flow and to provide guidelines for designing self-blast breaker with a higher interruption capability.

Artificial line for short-line fault test (근거리선로고장전류 차단시험용 Artificial line)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1783-1785
    • /
    • 2001
  • With the 4-MJ synthetic testing facilities completed, KERI can perform the circuit breaker testing up to 420 kV, 50 kA ratings. The short-line fault test is one of the necessary test items which are required for the circuit breaker, and in order to perform the short-line fault test KERI(Korea Electrotechnology Institute) has used the "new artificial line" which has small dimension and is easy to generate the saw-tooth wave. This paper describes the following items of the new artificial line. -Description of 4-kinds of artificial lines and determination of the circuit parameter of artificial line. -TRV characteristics of saw-tooth waves for each circuit. -KERI's artificial line.

  • PDF