• Title/Summary/Keyword: 극저온 냉각

Search Result 109, Processing Time 0.029 seconds

Case Studies for Optimizing Energy Efficiency of Propane Cycle Pressure Levels on C3-MR Process (C3-MR 공정의 프로판 사이클 압력 레벨에 따른 에너지효율 최적화를 위한 사례연구)

  • Lee, In-Kyu;Tak, Kyung-Jae;Lim, Won-Sub;Moon, Il;Kim, Hak-Sung;Choi, Kwang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.38-43
    • /
    • 2011
  • Natural gas liquefaction process runs under cryogenic condition, and it spends large amount of energy. Minimizing energy consumption of natural gas liquefaction process is an important issue because of its physical characteristics. Among many kinds of natural gas liquefaction processes, C3-MR(Propane Pre-cooled Mixed Refrigerant) process uses two kind of refrigerants. One is the propane as the pure refrigerant(PR) and the other is the mixed refrigerant(MR). In this study, to find the optimal compressing level, propane cycle is simulated on different pressure level. The case study result shows relationship between energy consumption and pressure level. As a result, the conclusion is that at a higher pressure level, process consumes lower energy. At 5 pressure-levels, energy consumption is 23.7% lower than 3 pressure-levels.

Evaluation of Structural Stability for a 75-tonf Class Thrust Chamber Mixing Head (75톤급 연소기 헤드부의 구조안정성 평가)

  • Ryu, Chul-Sung;Lee, Keum-Oh;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.515-519
    • /
    • 2011
  • Structural tests for the mixing head of a 75tonf class thrust chamber were performed to verify structural stability. The mixing head of a thrust chamber is loaded by high pressure with regeneratively cooled fuel and cryogenic liquid oxygen(LOx) as well as it transfers thrust load generated by liquid rocket engine. Therefore structural stability of mixing head is a very important factor to work without any plastic deformation or structural failure. In this study, two mixing heads were manufactured using different welding methods, Tungsten Inert Gas(TIG) welding and Electron Beam Welding(EBW) and evaluated a structural stability. The results of structural tests showed that the mixing head assembled by EBW can withstand the applied design load without any structural failures and be structurally more stable than that of TIG welding.

  • PDF

A Study on Structural Characteristics of SM490A TMC Thick Steel Plates (SM490A TMC 후판강재의 소재 및 용접부 특성에 관한 연구)

  • Kim, Jong Rak;Park, Yang Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.331-339
    • /
    • 2003
  • The study discussed in this paper investigated the material characteristics for the Thermo-Mechanical Control Process(TMCP) plates, which are controlled by several factors such as rolling, cold-stripping, cooling rate, and fixed carbon quantity. The suitability of thick TMCP steel plates as structural steel was also estimated through several experiments and with the us of a statistical method to analyze mill certificate sheets provided by the manufacturer. The results of this study are as follows: the TMCP steel plates showed stable values of the composition parameter ($P_cm$) and the carbon equivalents ($C_eq$ ) with satisfied yield strength, ultimate strength, and low-yield ratio.

Development of Active Micro-Vibration Isolator using Electromagnet (전자석을 사용한 능동 미소진동 절연장치 개발)

  • Lee, Dae-Oen;Park, Gee-Yong;Han, Jae-Hung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.390-394
    • /
    • 2013
  • Observation satellites carrying high precision optical payload require extremely stringent pointing stability that may be violated in the presence of the disturbances corning from reaction wheels, cryocoolers or other actuating components onboard the satellite. The most common method to protect the sensitive payloads from external disturbances is implementation of vibration isolator. In this paper development of a single axis active vibration isolator using electromagnet and its performance in isolating micro-vibration is presented. The main components of the developed isolator are membrane structure providing the isolator with the required stiffness and an electromagnet for active control. The performance test results show that additional damping can be achieved by active control without degrading isolation performance in high frequency region and that the developed isolator can effectively isolate micro-vibration.

  • PDF

The effect of Whole-body cryotherapy intervention after an eccentric exercise on PPT, CK and LDH of EIMD (원심성 운동 후 극저온 냉각치료 적용이 운동유발성 근육 손상 후 통증, CK 및 LDH에 미치는 효과)

  • Shin, Sung Phil;Kim, Ha Neul;Jeon, Jae Geun
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.3
    • /
    • pp.30-41
    • /
    • 2021
  • Background: The purpose of this study was to investigate the effects of WBC on the pressure pain threshold, CK and LDH after exercise-induced muscle injury. Design: A Randomized Controlled Trial. Methods: In this study, these subjects were assigned into three groups, a control group (n=10), experiment group I (n=10) and experiment group II (n=10). The subjects in experimental group I were intervened by WBC (-130℃, 3 minutes) before induced EIMD, experimental group II were intervened by WBC (-130℃, 3 minutes) after induced EIMD and control group weren't by any intervened after induced EIMD. Results: First, In the comparison of the PPT, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the PPT of experimental group II was significantly larger than those of other groups (p<.01). Second, In the comparison of the CK, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the CK of experimental group II was significantly smaller than those of other groups (p<.001). Third, In the comparison of the LDH, there were significant variations with the lapse the time in three groups (p<.01) and there was a significant interaction of time and group (p<.001). In the among group comparison, the LDH of experimental group II was significantly smaller than those of other groups (p<.001). Conclusion: The above results revealed that the WBC intervention after an exercise had a positive effect of muscle function after EIMD.

Performance Test of Cooling System for the KEPCO HTS Power Cable (한전 초전도전력케이블 냉각시스템 성능시험)

  • Yang, H.S.;Kim, D.L.;Sohn, S.H.;Lim, J.H.;Choi, H.O.;Lee, B.S.;Choi, Y.S.;Ryoo, H.S.;Hwang, S.D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

Design Optimization of Thermal Radiation Shield Cooled by Cryocooler (냉동기에 의해 냉각되는 복사열차폐 최적설계)

  • Choi, Y.S.;Tang, Hongming;Kim, D.L.;Yang, H.S.;Lee, B.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2171-2174
    • /
    • 2008
  • The design of thermal radiation shield cooled by a cryocooler is presented. This study is motivated mainly by our recent development of prototype superconducting magnet system for the Cyclotron K120. The superconducting magnet system is composed of the magnet cryostat, transfer line and supply cryostat. In order to minimize thermal radiation load, the superconducting coil form in the magnet cryostat is enclosed by the thermal radiation shield which is thermally connected to the first-stage cold head of a two-stage cryocooler in the supply cryostat. Since the supply cryostat is located far from the magnet cryostat large temperature gradient along the thermal shield is unavoidable. In this paper, the thermal radiation shield is optimized to minimize temperature gradient with taking into account the cryogenic load, system structure and electrical load. The effect of heat source from thermal conduction through mechanical supports on the temperature distribution of thermal radiation shield is also discussed.

  • PDF

Improvement of Insulation System for LNG Storage Tank Base Slab (LNG 저장탱크 바닥판 단열 시스템 개선)

  • Lee, Yong-Jin;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.141-147
    • /
    • 2010
  • Liquefied natural gas(LNG) is natural gas that has been converted temporarily to liquid form for ease of storage and transport it. Natural gas is the worlds cleanest burning fossil fuel and it has emerged as the environmentally preferred fuel of choice. In Korea, the demand of this has been increased since the first import from the Indonesia in 1986. LNG takes up about 1/600th the volume of natural gas in the gaseous state by cooling it to approximately $-162^{\circ}C(-260^{\circ}F)$. The reduction in volume therefore makes it much more cost efficient to transport and store it. Modern LNG storage tanks are typically the full containment type, which is a double-wall construction with reinforced concrete outer wall and a high-nickel steel inner tank, with extremely efficient insulation between the walls. The insulation will be installed to LNG outer tank for the isolation of cryogenic temperature. The insulation will be installed in the base slab, wall and at the roof. According to the insulation's arrangement, the different aspects of temperature transmission is shown around the outer tank. As the result of the thermal & stress analysis, by the installing cellular glass underneath the perlite concrete, the temperature difference is greatly reduced between the ambient temperature and inside of concrete wall, also reducing section force according to temperature load.

The effect of whole-body cryotherapy intervention after an exercise on MVIC and ROM of EIMD (운동 후 극저온 냉각치료 적용이 운동유발성 근육 손상의 최대등척성근력과 관절가동범위에 미치는 효과)

  • Shin, Sung Phil;Son, Gyeong Hyeon;Jeon, Jae Geun
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.45-55
    • /
    • 2020
  • Background: The purpose of this study was to investigate the effects of WBC (whole-body cryotherapy)on the MVIC (maximal voluntary isometric contraction)and active ROM (range of motion) recovery of after EIMD (exercise-induced muscle injury). Design: Randomized Controlled Trial. Methods: Thirty subjects who are student in their 20s at a university participated in this study, these subjects were assigned into three groups, a control group (n=10), experiment group I(n=10), and experiment group II (n=10). The subjects in the experimental group II were intervened by WBC (-130℃, 3 minutes) before induced EIMD, the experimental group were intervened by WBC (-130℃, 3 minutes) after induced EIMD, and the control group weren't by any intervened after induced EIMD. Results: First, In the comparison of the MVIC, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the MVIC of experimental group II was significantly larger than those of other groups (p<.001). Second, In the comparison of the active extension angle, there were significant variations with the lapse the time in three groups (p<.001) and there was a significant interaction of time and group (p<.001). In the among group comparison, the active extension angle of experimental group II was significantly smaller than those of other groups (p<.001). Third, In the comparison of the active flexion angle, there were significant variations with the lapse the time in three groups (p<.01) and there was a significant interaction of time and group (p<.001). In the among group comparison, the active flexion angle of experimental group II was significantly larger than those of other groups (p<.05). Conclusion: The above results revealed that the WBC intervention after an exercise had a positive effect of muscle function after EIMD. Therefore we can consider the WBC as a considerable intervention method to prevent or reduce an exercise injury.