• 제목/요약/키워드: 균질도

Search Result 2,089, Processing Time 0.037 seconds

S-Wave Velocities Beneath Jeju Island, Korea, Using Inversion of Receiver Functions and the H-κ Stacking Method (수신함수 역산 및 H-κ 중합법을 이용한 제주도 하부의 S파 지각 속도)

  • Jeon, Taehyeon;Kim, Ki Young;Woo, Namchul
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2013
  • Shear-wave velocity ($v_s$) structures beneath two seismic stations, JJU and JJB on the flanks of the volcano Halla on Jeju island, Korea, were estimated by receiver-function inversion and H-${\kappa}$ stacking applied to 150 teleseismic events ($M_W{\geq}5.5$) recorded since 2007. $P_S$ waves converted at the Moho discontinuity does not appear clearly for northwesterly back-azimuths ($207{\sim}409^{\circ}$, average $308^{\circ}$) at station JJU and southeasterly back-azimuths ($119{\sim}207^{\circ}C$, average $163^{\circ}$) at station JJB. This may be due to a gradual velocity increase at Moho or heterogeneity within the crust. The $v_s$ models derived by inversion of receiver functions indicate a distinct low velocity layer ($v_s{\leq}3.5km/s$; LVL) within the crust and a gradual increase in $v_s$ in the depth interval of 30 to 40 km. Within the radius of 18 km beneath station JJB, the LVL occurs at depths of 14 ~ 26 km and the 'Moho' ($v_s{\geq}4.3km/s$) is at 34 km depth. Ten kilometers to the west, within the radius of 16 km beneath station JJU, both the LVL and the Moho are significantly shallower, at depths of 14 to 24 km and 30 km, respectively. H-${\kappa}$ analyses for stations JJU and JJB yield estimated crustal thickness of 29 and 33 km and $v_p/v_s$ ratios of 1.64 and 1.75, respectively. The lesser $v_p/v_s$ ratio was derived for rocks nearest to th peak of the volcano.

Sm-Nd mineral ages of charnockites and ilmenite-bearing anorthositic rocks of Jirisan area and their genetic relationship (지리산 지역 차노카이트와 함티탄철석 회장암질암의 Sm-Nd 광물연대 및 성인적 관계)

  • 박계헌;김동연;송용선
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.27-35
    • /
    • 2001
  • The charnockite of Jirisan area occurs within the Precambrian high grade metamorphic terrane associated with anorthosite body as many foreign examples. Sm-Nd ages were determined from whole rock-garnet pairs, which turned out $1827\pm$32($2\sigma$) Ma for the massive charnockite and $1820\pm$22(2$\sigma$) Ma for the foliated charnockite with $$\varepsilon$_{Nd}(T)$ of $-5.5\pm$0.2 and $-6.0\pm$0.5 respectively. $^{87}Sr/^{86}Sr$ initial ratios calculated with the these ages are 0.71319 and 0.71532 respectively. The fact that massive and foliated charnockites show identical age, identical Nd isotopic initial ratio, and similar Sr isotopic initial ratios suggest that they were generated at the same time from the same material even through their present textures are different. Initial ratios of Nd and Sr of the charnockites are quite distinct from the mantle values indicating the influence of continental crust. Sm-Nd age determined from the titanium bearing anorthositic rocks intruding the anorthosite body, using mineral separates of garnet, plagioclase, and mafic fraction, is $1792\pm$90(2$\sigma$) Ma with $$\varepsilon$_{Nd}(T)=-3.9$\pm$0.2$. The ^${87}Sr/^{86}Sr$ initial ratios calculated with this age are 0.70616~0.70619. The charnockites and the anorthositic rocks occurring in contact each other also reveal the same age within the error, which suggest a genetic relationship between them. However, chemical compositions of the charnockites and Hadong-Sancheong anorthosites cannot be explained by igneous differentiation. Their differences in Nd and Sr initial isotopic ratios indicate different source materials. Therefore, temporal association between them suggests the possibility of the anorthosite acting as a thermal source for the generation of the charnockite as other studies.

  • PDF

Structural characteristics of Humboldt Range, northwest Nevada, U. S. A. (미국 북서 네바다주 험볼트 산맥의 구조분석)

  • 정상원
    • The Journal of the Petrological Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.131-148
    • /
    • 1999
  • Characteristics and complex structures in the northwest Nevada, U.S.A. are de-veloped due to relative tectonic movement of major tectonostratigraphic terranes. Theresearch area is composed of autochthonous rocks of both Early Triassic Koipato Group and Middle Triassic Star Peak Group, which is located in the Humboldt Range, northwest Nevada, U.S.A. The present research is focused on deformation history, related fabric development, and state of regional paleostress during the Jurassic to Late Cretaceous. The Triassic autochthonous rocks in the Humboldt Range, Nevada, U.S.A. display polyphase deformation due to E- to ESE-directed tectonic transport of the Fencemaker allochthon over autochthonous rocks of the Humboldt Range. Structures involving the Mesozoic foreland deformation are development of intense foliation, different styles of folds, minor thrusts, transposed layering, and strong mylonitization. These tectonic structures are mostly developed along the western flank of the Humboldt Range, and are reported as the first deformation of the Mesozoic foreland in the Humboldt Range, Nevada, U.S.A. Regional principal stress(${\sigma}_1$) is interpreted to be E to ESE between the Jurassic and Early Cretaceous on the basis of orientations of strongly developed $D_1$ structures. The deformation during the Middle to Late Cretaceous, is characterized by development of consistent N- to NNE-trending metamorphic quartz veins, and shear zones parallel to pre-existing $D_1$ foliation. Orientations of metamorphic quartz veins as well as other kinematic indicators are N to NNE and are interpreted as those of regional principal stress(${\sigma}_1$) during the Late Cretaceous. The sense of shear applied in the Humbololt Range is dextral and is caused by reactivation of early-formed $D_1$ structures. These results reflect counterclockwise rotation of regional principal paleostress in the Humboldt Range from the Jurassic to Late cretaceous. Finally, development of both shear band cleavage and S/C mylonitic fabrics indicates that the shear zones in the Humboldt Range reflect involvement of enhanced non-coaxial flow during bulk shortening in mylonitic formation.

  • PDF

Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers (폐암환자의 종양추적 정위방사선치료를 위한 삼차원 및 사차원 방사선치료계획의 비교)

  • Chai, Gyu-Young;Lim, Young-Kyung;Kang, Ki-Mun;Jeong, Bae-Gwon;Ha, In-Bong;Park, Kyung-Bum;Jung, Jin-Myung;Kim, Dong-Wook
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.238-248
    • /
    • 2010
  • Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

Primer Evaluation for the Detection of Toxigenic Microcystis by PCR (독소 생성 Microcystis 검출을 위한 PCR primer의 평가)

  • 이현경;김준호;유순애;안태석;김치경;이동훈
    • Korean Journal of Microbiology
    • /
    • v.39 no.3
    • /
    • pp.166-174
    • /
    • 2003
  • Microcystin produced by cyanobacteria in surface waters, such as eutrophic lake and river, is a kind of serious environmental problems due to its toxicity to human and wild animals. Microcystin is synthesized nonribosomally by the large modular multi-functional enzyme complex known as microcystin synthetase encoded by the mcy gene cluster. Amplification of mcy genes by PCR from cultures and environmental samples is a simple and efficient method to detect the toxigenic Microcystis. In order to evaluate primers designed to detect toxic microcystin-producing strains, 17 cyanobacterial strains and 20 environmental samples were examined by PCR with 7 pairs of primers. Some microcystin-producing cyanobacteria were not detected with FAA-RAA, TOX4F-TOX4R and FP-RP primers. The fragment of unexpected size was amplified with NSZW2-NSZW1 primers in Microcystis strains isolated from the lakes in Korea. TOX1P-TOX1F primers failed in amplification of toxin-producing strains. Only MSF-MSR and TOX2P- TOX2F primers amplified the fragments of mcy genes from 11 strains of microcystin-producing Microcystis. The water samples taken from 20 lakes in Korea were analyzed by PCR using each of the primers. In all the water samples, cyanobacteria capable of producing microcystin were detected by the PCR with TOX2P-TOX2F primers. These results indicate that TOX2P-TOX2F primers are better than the other primers for detection of microcystin-producing Microcystis strains in Korea. The nucleotide sequences of mcy gene in Microcystis aeruginosa NIER10010 suggest genetic diversity of Korean isolates.

Interpretation of Limestone Provenance, Materials and Making Characteristics for Lime-Soil Mixture on Tomb Barrier of the Yesan Mokri Site in Joseon Dynasty (조선시대 예산 목리유적 회격묘의 재질 및 제작특성과 석회의 산지 해석)

  • Lee, Chan Hee;Cho, Ji Hyun;Kim, Jiyoung
    • Journal of Conservation Science
    • /
    • v.32 no.4
    • /
    • pp.471-490
    • /
    • 2016
  • This study investigated provenance of raw materials and making technique of lime-based materials used in the tomb barriers of the Yesan Mokri tombs from Joseon dynasty on the basis of analysis to material characteristics and physical properties. In the barrier materials, dry density and porosity are the highest value ($1.82g/cm^3$) and the lowest value (25.20%) in the south wall of No. 1 tomb, respectively. Dry density and porosity are inversely proportional in all barrier materials, but unconfined compressive strength, which is the highest value of $182.36kg/cm^2$ in the No. 2 tomb, does not show an interrelation with porosity and density. Mineral components in the lime-soil mixtures of the tomb barrier are mainly quartz, feldspar, mica and calcite about 200 to $600{\mu}m$ size with yellowish brown matrix. Hydrotalcite and portlandite are detected in the lime mixture, and kaolinite in the soils. The lime materials of the tomb barrier occurred in large quantities weight loss and variable endothermic peaks caused by decarbonization reaction of $CaCO_3$ in the range from 600 to $800^{\circ}C$ in thermal analysis. Making temperature of lime for the tomb barrier is presumed approximately about $800^{\circ}C$ based on the occurrences, compositions and thermal analysis. The tomb barriers are revealed to very wide composition ranges of major elements and loss-on-ignition (22.5 to 33.6 wt.%) owing to mixture of the three materials (lime, sand and clay). It is interpreted that low quality construction technique was applied as the limes are very heterogeneous mixture with aggregates, and curing of the lime was poorly processed in the tomb barriers. Possible limestone sources are distributed in many areas around the Mokri site where limestone conformation and quarries for commercial production are found within Yesan and Hongseong areas. Therefore, we estimated that raw materials were possibly supplied from the local mines near the Mokri site.

A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer (비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구)

  • Yeom, Misuk;Lee, Woosuk;Kim, Daesup;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Purpose : For non-small cell lung cancer, if the treatment volume is large or the total lung volume is small, and the tumor is located in midline of patient's body, total lung dose tends to increase due to tolerance dose of spinal cord. The purpose of this study is to compare and evaluate the total lung dose of three dimensional conformal radiotherapy(3D CRT), intensity modulated radiotherapy(IMRT) and volumetric modulated arc therapy(VMAT) using restricted angle for non-small cell lung cancer patients. Materials and Methods : The treatment plans for four patients, being treated on TrueBeam STx($Varian^{TM}$, USA) with 10 MV and prescribed dose of 60 Gy in 30 fractions, 3D CRT, restricted angle IMRT and VAMT radiotherapy plans were established. Planning target volume(PTV), dose to total lung and spinal cord were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV, $V_{30}$, $V_{20}$, $V_{10}$, $V_5$, mean dose for total lung and maximum dose for spinal cord was assessed. Results : Average value of CI, HI and PCI for PTV was $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$ respectively. $V_{20}$ values from 3D CRT, IMRT and VMAT plans were 30.7%, 20.2% and 21.2% for the first patient, 33.0%, 29.2% and 31.5% for second patient, 51.3%, 34.3% and 36.9% for third patient, finally 56.9%, 33.7% and 40.0% for the last patient. It was noticed that the $V_{20}$ was lowest in the IMRT plan using restricted angle. Maximum dose for spinal cord was evaluated to lower than the tolerance dose. Conclusion : For non-small cell lung cancer, IMRT with restricted angle or VMAT could minimize the lung dose and lower the dose to spinal cord below the tolerance level. Considering PTV coverage and tolerance dose to spinal cord, it was possible to obtain IMRT plan with smaller angle and this could result in lower dose to lung when compared to VMAT.

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.