• Title/Summary/Keyword: 균일률

Search Result 340, Processing Time 0.033 seconds

Center of Photon Mass as a Unified Design Parameter II : Quarter Wavelength Shifted DFB Lasers (DFB 레이저의 통합된 설계 변수로서의 광자 분포 중심 II : ${\lambda}$/4 위상 천이 구조)

  • Kim, Sung-Han;Kim, Sang-Bae
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.12
    • /
    • pp.63-69
    • /
    • 1999
  • Center of photon mass, defined as the center of axial photon distribution in each half, is proposed as a unified design parameter in quarter wavelength shifted(QWS) DFB lasers. Shown is the way the parameter is related to the threshold pain difference and uniformity in axial photon density, which determine single-frequency stability of DFB lasers. Also, a general rule for single-frequency DFB laser design is presented. Using the design rule, we propose a sampled grating QWS-DFB laser that has a wider $_KL$ range 0f 100% single-frequency yield.

  • PDF

수직형 LED 소자의 광출력 향상을 위한 나노 패터닝 공정

  • Byeon, Gyeong-Jae;Park, Hyeong-Won;Jo, Jung-Yeon;Lee, Seong-Hwan;Lee, Heon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.32.2-32.2
    • /
    • 2010
  • 본 연구에서는 고출력, 고휘도를 위해서 개발되고 있는 수직형 LED소자의 광출력향상을 위한 나노 패터닝 공정을 진행하였다. 수직형 LED는 기존 측면형 LED에 비해서 열방출 특성이 우수하고 대면적 칩으로 제작이 가능하기 때문에 높은 광출력이 필요한 조명 분야로의 적용이 가능하다. 하지만 수직형 LED 역시 기존 측면형 LED와 마찬가지로 질화갈륨 및 외부 공기와의 계면에서 전반사가 심하기 때문에 광추출효율이 낮은 문제점이 있으며 이를 해결하는 것이 큰 이슈가 되고 있다. 이를 해결하기 위해서 광결정 패턴을 LED 소자에 형성하여 광추출효율을 향상시키려는 연구가 활발히 진행되고 있으나 아직까지 수직형 LED 웨이퍼 전면적에 균일한 패턴을 형성할 수 있는 기술 개발이 미진한 상황이다. 본 연구에서는 유연 고분자 몰드를 이용한 대면적 나노 임프린팅 및 나노 프린팅 기술을 통해서 2 inch 수직형 LED 웨이퍼 전면적에 균일한 패턴을 전사하는 공정을 진행하였다. 구체적으로는 나노임프린트 및 건식식각 공정을 통해서 수직형 LED의 n형 질화갈륨 층에 높은 가로세로비의 광결정 패턴을 형성하였으며 이를 통해서 약 40% 정도의 광출력이 향상되었다. 또한 고 굴절률의 산화아연 나노 패턴 형성공정을 대면적 LED 기판에 시도하였다.

  • PDF

Cellular Automaton Models Revealing Effects of Initial Bacterial Distribution on Biofilm Growth (생물막 성장에 대한 세균의 초기 분포영향을 나타내는 셀룰라오토마톤 모델)

  • Lee, Sang-Hee;Choi, Kyung-Hee;Chon, Tae-Soo
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.297-303
    • /
    • 2004
  • Two dimensional cellular automaton (CA) models were developed to investigate growth of biofilms in aquatic ecosystems. Simple local rules on CA were applied to governing growth of bacterial populations in relation to different nutrient concentrations. Initial bacterial distribution played an important role in determining population size and morphology of biofilm at low concentrations of nutrition. With clumped distribution, population size increased slowly compared with uniform and random distributions, while the porosity tented to be higher with uniform distribution compared with other initial distributions.

A Study on the Design and Fabrication of the Planar Light Waveguide type $2\times32$ Optical Coupler (평면도파로형 $2\times32$ 광커플러의 설계와 제작에 관한 연구)

  • 신기수;최영복;류근호;문동찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12B
    • /
    • pp.2335-2341
    • /
    • 1999
  • The $2\times32$ coupler consists of Mach-Zehnder interferometer and Y branch coupler. For the designs of this coupler, three dimensional rectangular core waveguide decomposed to two-dimensional structure by the effective index method. To optimize the waveguide structure, the confinement factor was investigated with two-dimensional finite difference Beam Propagation Method. The $2\times32$ coupler fabricated by simulation with height between Mach-Zehnder arms, H=$43.6\mu\textrm{m}$(path difference $0.668\mu\textrm{m}$) was showed best characteristics. In the results of dry etching of core layer, the etching rate of core layer was above 2600${\AA}$/min, the etching ratio of SiO2 to Al mask was 30:1 and the uniformity of etching was $\pm$5%. The maximum insertion loss and the uniformity of $2\times32$ coupler were below 19.2dB, 2dB respectively.

  • PDF

mechanism of Equivalent Power Distribution in Parallel Connected ICP for Large Area Processing

  • Lee, Jin-Won;Bae, In-Sik;An, Sang-Hyeok;Jang, Hong-Yeong;Yu, Sin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.510-510
    • /
    • 2012
  • 반도체, 디스플레이, 태양광 등의 공정에서 사용되는 웨이퍼의 크기가 증가하고, 생산률이 플라즈마의 밀도에 비례한다는 연구 결과가 발표되면서 대면적 고밀도 플라즈마 소스 개발에 대한 연구가 활발히 진행되고 있다. 특히, ECR, ICP, Helicon plasma 등 고밀도 플라즈마 소스에 대한 관심이 높아지고 있다. 이에 따라, 여러 개의 ICP를 결합한 multiple ICP를 이용해 대면적 고밀도 플라즈마 소스 개발을 진행했다. Multiple ICP의 경우 각 ICP 소스에 같은 power (current)를 공급해야만 균일한 플라즈마 방전이 발생되어 균일도를 확보 할 수 있다. Current controller 같은 추가적인 장비를 설치하지 않고, power를 분배하는 transmission line을 coaxial 형태로 설계하고 같은 길이로 병렬 연결함으로써 각각의 ICP소스에서 균일한 플라즈마를 방전시킬 수 있었다. Power generator에서 보는 각 ICP의 total impedance는 각 ICP 소스의 impedance와 coaxial 형태의 transmission line의 characteristic impedance, frequency, 길이의 함수로 구할 수 있고, 이 total impedance가 일정하기 때문에 current가 균등하게 분배되어 각 ICP소스에 균등한 power 분배가 가능한 것이다. 실질적으로 ICP 소스의 impedance는 플라즈마 방전 유무에 따라 변화하기 때문에 일정하게 유지하는 것은 어렵다. Transmission line의 characteristic을 사용함으로써 ICP의 impedance의 변화에 상관없이 Total impedance를 일정하게 유지시킴으로써 균등한 power 분배가 가능하다는 것을 연구했다. Frequency는 13,56MHz, characteristic impedance를 $50{\Omega}$ (coaxial cable)으로 고정하고, ICP 소스의 플라즈마 방전 유무/antenna turn/소스 위치에 따른 total impedance를 transmission line의 길이에 따라 측정하고, 이를 이론값, 그래프와 비교하였다. 특정 length에서 플라즈마 방전 유무(ICP의 impedance 변화)와 상관없이 비교적 일정한 total impedance를 유지하는 것을 확인 했다. 이것은 특정 길이를 갖는 coaxial형태의 transmission line를 연결하면, total impedance는 플라즈마 방전 유무로 발생하는 ICP의 impedance 변화와 상관없이 일정하게 유지되어 각 ICP소스에 균등한 파워 분배가 가능하다는 것을 보여준 결과이다. 이것을 토대로 frequency에 따라(또는 characteristic impedance에 따라) 균등한 파워 분배가 가능한 coaxial 형태 transmission line의 특정 길이를 구할 수 있고, 대면적 소스에서 균등한 파워 분배를 위한 병렬연결에 적용할 수 있을 것이다.

  • PDF

Fabrication of Organic-Inorganic Nanocomposite Blade for Dicing Semiconductor Wafer (반도체 웨이퍼 다이싱용 나노 복합재료 블레이드의 제작)

  • Jang, Kyung-Soon;Kim, Tae-Woo;Min, Kyung-Yeol;Lee, Jeong-Ick;Lee, Kee-Sung
    • Composites Research
    • /
    • v.20 no.5
    • /
    • pp.49-55
    • /
    • 2007
  • Nanocomposite blade for dicing semiconductor wafer is investigated for micro/nano-device and micro/nano-fabrication. While metal blade has been used for dicing of silicon wafer, polymer composite blades are used for machining of quartz wafer in semiconductor and cellular phone industry in these days. Organic-inorganic material selection is important to provide the blade with machinability, electrical conductivity, strength, ductility and wear resistance. Maintaining constant thickness with micro-dimension during shaping is one of the important technologies fer machining micro/nano fabrication. In this study the fabrication of blade by wet processing of mixing conducting nano ceramic powder, abrasive powder phenol resin and polyimide has been investigated using an experimental approach in which the thickness differential as the primary design criterion. The effect of drying conduction and post pressure are investigated. As a result wet processing techniques reveal that reliable results are achievable with improved dimension tolerance.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

플라즈마 공정 진단을 위한 공간 분해 발광 분광 분석법 소개

  • Park, Chang-Hui;Kim, Dong-Hui;Choe, Seong-Won;Lee, Chang-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.81-81
    • /
    • 2013
  • 반도체, LCD, MEMs 등 미세 전자소자의 제작과 깊은 관련이 있는 IT 산업은 자동차 산업과 함께 세계 경제를 이끌고 있는 핵심 산업이며, 그 발전 가능성이 크다고 할 수 있다. 이 중 반도체, LCD 공정 기술에 관해서 대한민국은 세계를 선도하여 시장을 이끌어 나가고 있는 실정이다. 이들의 공정기술은 주로 높은 수율(yield)을 기반으로 한 대량 생산 기술에 초점이 맞추어져 있기 때문에, 현재와 같은 첨예한 가격 경쟁력이 요구되는 시대에서 공정 기술 개발을 통해 수율을 최대한으로 이끌어 내는 것이 현재 반도체를 비롯한 미세소자 산업이 직면하고 있는 하나의 중대한 과제라 할 수 있다. 특히 반도체공정에 있어 발전을 거듭하여 현재 20 nm 수준의 선폭을 갖는 소자들의 양산이 계획 있는데 이와 같은 나노미터급 선폭을 갖는 소자 양산과 관련된 CD (critical dimension)의 감소는 공차의 감소를 유발시키고 있으며, 패널의 양산에 있어서 생산 효율 증가를 위한 기판 크기의 대형화가 이루어지고 있다. 또한, 소자의 집적도를 높이기 위하여 높은 종횡비(aspect ratio)를 요구하는 공정이 일반화됨에 따라 단일 웨이퍼 내에서의 공정의 균일도(With in wafer uniformity, WIWU) 및 공정이 진행되는 시간에 따른 균일도(Wafer to wafer uniformity)의 변화 양상에 대한 파악을 통한 공정 진단에 대한 요구가 급증하고 있는 현실이다. 반도체 및 LCD 공정에 있어서 공정 균일도의 감시 및 향상을 위하여 박막, 증착, 식각의 주요 공정에 널리 사용되고 있는 플라즈마의 균일도(uniformity)를 파악하고 실시간으로 감시하는 것이 반드시 필요하며, 플라즈마의 균일도를 파악한다는 것은 플라즈마의 기판 상의 공간적 분포(radial direction)를 확인하여 보는 것을 의미한다. 현재까지 플라즈마의 공간적 분포를 진단하는 대표적인 방법으로는 랭뮤어 탐침(Langmuir Probe), 레이저 유도 형광법(Laser Induced Fluorescence, LIF) 그리고 광섬유를 이용한 발광분광법(Optical Emission Spectroscopy, OES)등이 있으나 랭뮤어 탐침은 플라즈마 본연의 상태에서 섭동(pertubation) 현상에 의한 교란, 이온에너지 측정의 한계로 인하여 공정의 실시간 감시에 적합하지 않으며, 레이저 유도 형광법은 측정 물질의 제한성 때문에 플라즈마 내부에 존재하는 다양한 종의 거동을 살필 수 없다는 단점 및 장치의 설치와 정렬(alignment)이 상대적으로 어려워 산업 현장에서 사용하기에 한계가 있다. 본 연구에서는 최소 50 cm에서 최대 400 cm까지 플라즈마 내 측정 거리에서 최대 20 mm 공간 분해가 가능한 광 수광 시스템 및 플라즈마 공정에서의 라디칼의 상태 변화를 분광학적 비접촉 방법으로 계측할 수 있는 발광 분광 분석기를 접목하여 플라즈마 챔버 내의 라디칼 공간 분포를 계측할 수 있는 진단 센서를 고안하고 이를 실 공정에 적용하여 보았다. 플라즈마 증착 및 식각 공정에서 형성된 박막의 두께 및 식각률과 공간 분해발광 분석법을 통하여 계측된 결과와의 매우 높은 상관관계를 확인하였다.

  • PDF

Unproved AMC-MIMO Multiplexing Systems Using Selection Transmit Diversities (선택적 전송다이버시티를 사용한 개선된 AMC-MIMO 다중화시스템)

  • Kang, Min-goo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.652-657
    • /
    • 2003
  • In this paper, Adaptive Modulation and Coding (AMC) is combined with Multiple Input Multiple Output (MIMO) multiplexing to improve the throughput performance of AMC. In addition, a system that adopts Selection Transmit Diversity (STD) in the AMC-MIMO multiplexing system is proposed. The received SNR is improved by adopting STD techniques. And it increases probability of selecting MCS (Modulation and Coding Scheme) level that supports higher data rate. This leads to an increased throughput of the AMC-MIMO system. STD in our simulation selects 2 transmission antennas from 4 antennas and AMC-MIMO multiplexing process operates with the selected antennas. The computer simulation is performed in flat Rayleigh fading channel. The results show that the proposed system achieves a gain of 1Mbps over the AMC-MIMO multiplexing system with the same number of antennas at 15dB SNR.

Removal Characteristics of Toluene in Biofilters Packed with Reticulated-PU-Foams of Different Porosities (서로 다른 공극률의 망상형 폴리우레탄들이 충전된 바이오필터에서 톨루엔 제거 특성)

  • 명성운;남윤수;이용우;최호석
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.448-454
    • /
    • 2003
  • We studied on the removal of toluene vapors in a lab-scale biofilter. There are three biofilters packed with reticulated polyurethane foams of different porosities of 15, 25, 45 PPI (Pore Per Inch) as media. A toluene-degrading strain (Pseudomonas Putida KCCM 11348, ATCC 12633) was naturally immobilized on the filter media by circulating the culture media. Three biofilters were operated under different sets of continuous experiments, varying both the design and operation parameters such as the inlet toluene concentration and the flow rate. Maximum elimination capacity of 115.5g/㎥hr of biofilter packed with foams of 25 PPI was obtained for toluene degradation. The effect of operating conditions such as flow rate, inlet toluene concentration and porosity on the performance of the biofilter was investigated.